Search


arrester 3 to 36kV Station Class Optima arrester

  • arrester 3 to 36kV Station Class Optima arrester

Key attributes

Brand ROCKWILL
Model NO. arrester 3 to 36kV Station Class Optima arrester
Rated voltage 36kV
Series YH10W
Description

IEEE Riser Pole Class Polymer Housed Surge Arrester

PVR Optima arresters are suitable for Riser pole applications. While Riser is not a distinct IEEE or IEC class of arrester, the PVR Optima design meets the Heavy Duty requirements of IEEE C62.11. This arrester offers an enhanced protective capability when compared to the PDV-100 Optima. This arrester class is suitable for withstanding a 100 kA high current impulse. An option is only available for Imperial hardware.

High quality distribution surge arresters 

  • Long lasting ESPTM housing material with superior mechanical strength and electrical characteristics

  • Reliable capacitive disconnector operates at fault currents as low as 1 Amp

  • Dynamic triple sealing system protects internal components from moisture ingress to extend service lifetime

  • 100% routine tested

 

Technology parameters

Electrical Characteristics
Base Imperial Catalog Number MCOV (kV) Duty Cycle Rating (kV) Temporary overvoltage capability (kV) No prior duty Max steep current impulse residual voltage (kV) Max switching impulse residual voltage (kV) Max lightning impulse residual voltage (kV)
1 s 10 s 10 kA 0.5 kA 1.5 kA 3 kA 5 kA 10 kA 20 kA 40 kA
221603 2.55 3 3.6 3.4 11 7.1 7.7 8.2 8.7 9.4 10.6 12.3
221605 5.1 6 7.2 6.9 21.8 14.2 15.4 16.4 17.3 18.9 21.1 24.6
221608 7.65 9 10.8 10.3 28.9 19.2 20.8 22.1 23.3 25.4 28.4 33.1
221609 8.4 10 11.9 11.3 32 21.3 23.1 24.6 25.9 28.2 31.6 36.8
221610 10.2 12 14.4 13.8 38.3 25.5 27.7 29.5 31 33.8 37.9 44.1
221613 12.7 15 18 17.1 48.2 32 34.6 36.9 38.8 42.3 47.4 55.1
221615 15.3 18 21.6 20.7 57.4 38.3 41.5 44.2 46.6 50.7 56.8 66.1
221617 17 21 24.1 23 63.8 42.6 46.2 49.1 51.8 56.4 63.2 73.5
221620 19.5 24 27.6 26.3 76.5 51.1 55.3 58.9 62.1 67.6 75.8 88.1
221622 22 27 31.1 29.7 83.3 55.3 59.9 63.8 67.2 73.3 82 95.5
221624 24.4 30 34.5 32.9 96.4 63.9 69.2 73.7 77.7 84.6 94.8 110.3
221629 29 36 41 39.2 111.7 74.5 80.7 85.9 90.5 98.6 110.4 128.5

 

Electrical Characteristics
Base Imperial Catalog Number MCOV (kV) Duty Cycle Rating (kV) Temporary overvoltage capability (kV) No prior duty Max steep current impulse residual voltage (kV) Max switching impulse residual voltage (kV) Max lightning impulse residual voltage (kV)
1 s 10 s 10 kA 0.5 kA 1.5 kA 3 kA 5 kA 10 kA 20 kA 40 kA
221603 2.55 3 3.6 3.4 11 7.1 7.7 8.2 8.7 9.4 10.6 12.3
221605 5.1 6 7.2 6.9 21.8 14.2 15.4 16.4 17.3 18.9 21.1 24.6
221608 7.65 9 10.8 10.3 28.9 19.2 20.8 22.1 23.3 25.4 28.4 33.1
221609 8.4 10 11.9 11.3 32 21.3 23.1 24.6 25.9 28.2 31.6 36.8
221610 10.2 12 14.4 13.8 38.3 25.5 27.7 29.5 31 33.8 37.9 44.1
221613 12.7 15 18 17.1 48.2 32 34.6 36.9 38.8 42.3 47.4 55.1
221615 15.3 18 21.6 20.7 57.4 38.3 41.5 44.2 46.6 50.7 56.8 66.1
221617 17 21 24.1 23 63.8 42.6 46.2 49.1 51.8 56.4 63.2 73.5
221620 19.5 24 27.6 26.3 76.5 51.1 55.3 58.9 62.1 67.6 75.8 88.1
221622 22 27 31.1 29.7 83.3 55.3 59.9 63.8 67.2 73.3 82 95.5
221624 24.4 30 34.5 32.9 96.4 63.9 69.2 73.7 77.7 84.6 94.8 110.3
221629 29 36 41 39.2 111.7 74.5 80.7 85.9 90.5 98.6 110.4 128.5

 

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register