• SF6-free air-insulated switchgear for secondary distribution/Ring Main Unit
SF6-free air-insulated switchgear for secondary distribution/Ring Main Unit
discuss personally
Model
UniSec Air-24
Basic info
Brand ABB
Model NO. SF6-free air-insulated switchgear for secondary distribution
Rated voltage 24kV
Rated frequency 50/60Hz
Series UniSec Air
Product Detail

Description:

UniSec Air is a medium voltage switchgear designed for secondary distribution up to 24kV, 630A, 20kA. It contains GSec Air, three-position load break switch or disconnector and earthing switch. This new component has a shunt vacuum interrupter for breaking capacity, dry air as the insulation medium, and a global warming potential (GWP) of zero. The switchgear also contains a vacuum circuit breaker and is fully compliant with IEC standards and the U F-gas regulation (EU) 2024 / 573. 
The switchgear is based on a highly flexible and modular  concept with standardized solutions that can be  readily configured to meet the specific needs of each application. UniSec Air is fully tested according to IEC standard 62271-200. 
UniSec Air is internal arc classified, IAC A FLR up to 20 kA, assuring safe operations for technicians when standing in  front of the switchgear. Robust control and protection, metering, monitoring, and diagnostics suitable for various applications are also available. 
UniSec Air is designed with a refined interface and with  the same footprint, operations, and backward compatibility as the original UniSec switchgear,facilitating integration into existing systems and extensions of the installed base.

Customer benefits:

F-gas regulation compliance 

  • Fully compliant with the EU F-gas regulation (EU) 2024 / 573

  • GWP of 0

Flexible and modular design

  • Better accessibility to MV cable connection and simplified installation, use, and maintenance.

  • Wide range of functional units equipped with LBS and disconnector, circuit breaker, conventional measuring transformers, current and voltage sensors, and protection relay solutions, making it suitable for most indoor applications.

  • Provides flexibility for a high level of customization to meet demanding requirements and is easy to order thanks to user-friendly configurator tools.

  • Compact design with multiple functional units width 375, 500 and 750mm for installation in a wide variety of electrial rooms and layouts.

  • Backward compatibility between UniSec Air and UniSec allows for easy integration into existing systems and extensions of the installed base.

 Safe and Reliable

  •  Internal arc classification available with various gas exhaust variants  for enhanced safety.

  • Service continuity solutions LSC2B / LSC2A / LSC2 tailored for application needs, ensuring minimal service interruption.

  • High operator safety features an internal arc-proof design and a wide range of mechanical and electrical interlocks to enhance operator safety.

  • The GSec Air component has an internal volume of less than 25 liters.

  • Fast and dependable delivery times with pre-engineered just to install (JTI) switchgear solutions.

Main Technical Characteristics:

 GSec Air:

 

Know your supplier
ABB
As an authorized distributor of ABB products, we take great pride in our partnership.
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus
Business Type
Sales
Highest Annual Export (USD)
$580000000
Professional Experience
11 years
Workplace
20000m²
占位
占位
Documents
Public.
SF6-free air-insulated switchgear for secondary distribution
Manual English
PDF
FAQ
Q: What standards and certifications that ABB’s medium voltage switchgear products comply with?
A:
Our medium voltage switchgear products comply with international standards such as IEC 62271, GOST, GB/DL. They are also certified by leading industry bodies to ensure the highest levels of safety and performance. ABB also offers medium voltage switchgear products for ANSI standards.
Q: What’s the difference in the circuit breaker for air-insulated vs gas-insulated?
A:
Air-insulated switchgear circuit breaker is typically removable or withdrawable. The circuit breaker is based on vacuum circuit technology. In the gas-insulated, it is fixed mounted. The function of withdraw is provided by a separate disconnecting switch. Typically, a three-position switch with connected, disconnected, and ready-to-earth position.
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!