• 10MVA Industrial Use Cast-Resin Pad-Mounted Transformer
10MVA Industrial Use Cast-Resin Pad-Mounted Transformer
discuss personally
Model
ZGS-10000-33/0.69
Basic info
Brand Vziman
Model NO. 10MVA Industrial Use Cast-Resin Pad-Mounted Transformer
Primary voltage 33kV
Series ZGS
Product Detail

Description

10MVA Industrial cast-resin pad-mounted transformers are large-capacity, fully enclosed dry-type power distribution devices specifically designed for harsh industrial environments. Their core features include:

  • Cast-Resin Insulation: High-voltage windings use epoxy resin vacuum casting technology, offering full insulation and maintenance-free performance, in compliance with IEC 60076-11 standards.
  • Pad-Mounted Structure: Suitable for outdoor installation, with an IP65 protection rating (dustproof and waterproof), and can be directly placed on concrete foundations.
  • Industrial-Grade Design: Capable of withstanding high-load impacts, harmonic pollution, and extreme climates (operating temperature range: -40°C to +70°C).

Functions, Technical Realization, and Industrial Value

  • Power Conversion: Steps down medium voltage (e.g., 35kV) to industrial power voltage (6.6kV/690V) to meet the power supply requirements of large equipment.
  • Safety Isolation: Adopts an oil-free design (fire rating F1), suitable for inflammable and explosive areas, effectively reducing factory fire risks.
  • Harmonic Suppression: Equipped with an internal aluminum shielding layer, capable of withstanding total harmonic distortion (THD) ≤8% to protect precision industrial equipment from harmonic interference.
  • Overload Capacity: Supports 120% load for 4 consecutive hours and 150% load for 1 hour (in line with IEC 60076-12 standards), addressing peak production loads.

Typical Application Scenarios

Heavy Industry Sector

  • Iron and Steel Metallurgy: Powers arc furnaces, rolling mills, etc., with the ability to withstand frequent short-circuit impacts.
  • Chemical Parks: Adopts anti-corrosion design (316 stainless steel casing) to adapt to corrosive environments with hydrogen sulfide (H₂S), chlorine (Cl₂), etc.
  • Automotive Manufacturing: Used with frequency converter loads, suppressing harmonic interference by configuring 12% reactance rate.

Energy Infrastructure

  • PV/Wind Power Step-Up: Integrates DC component blocking function on the 35kV side, suitable for new energy power generation scenarios.
  • Data Centers: Pursues 99.99% power availability with dual-winding redundancy design.

Special Environments

  • Mining: Features seismic design compliant with EN 60068-3-3 Class 2 standards, adapting to underground vibration environments.
  • Ports: Adopts salt spray protection design, reaching ISO 9227 C5-M grade to resist marine climate erosion.

Parameter:

 

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!