6kV Outdoor static var generator(SVG)

  • 6kV Outdoor static var generator(SVG)
  • 6kV Outdoor static var generator(SVG)

Key attributes

Brand RW Energy
Model NO. 6kV Outdoor static var generator(SVG)
Rated voltage 6kV
Cooling mode Forced air cooling
Range of rated capacity 1~4 Mvar
Series RSVG

Product descriptions from the supplier

Description

Product Overview

The 6kV outdoor static reactive power generator (SVG) is a high-performance dynamic reactive power compensation device designed specifically for medium and high voltage distribution networks. It adopts an outdoor specific design (protection level IP44) and is suitable for complex outdoor working conditions. The product uses a multi chip DSP+FPGA as the control core, integrating instantaneous reactive power theory control technology, FFT fast harmonic calculation technology, and high-power IGBT driving technology. It is directly connected to the power grid through a cascaded power unit structure, without the need for additional boosting transformers, and can quickly and continuously provide capacitive or inductive reactive power. At the same time, it achieves dynamic harmonic compensation, effectively improves power quality, enhances grid stability, and has high reliability, ease of operation, and excellent performance. It is the core compensation solution for outdoor industrial scenes and power systems.

System structure and working principle

Core structure

  • Cascade power unit: adopting a cascade design, integrating multiple sets of high-performance IGBT modules, and withstanding high voltage of 6kV~35kV through series connection to ensure stable operation of the equipment.

  • Control core: Equipped with a multi chip DSP+FPGA control system, it has fast computing speed and high control accuracy. It communicates with various power units through Ethernet, RS485 and other interfaces to achieve status monitoring and command issuance.

  • Auxiliary structure: Configure a grid side coupling transformer with functions of filtering, current limiting, and suppressing current change rate; The outdoor cabinet meets the IP44 protection standard and is suitable for harsh outdoor environments.

Working principle

  • The controller monitors the load current of the power grid in real-time. Based on the theory of instantaneous reactive power and FFT fast harmonic calculation technology, it instantly analyzes the required reactive current and harmonic components. Through PWM pulse width modulation technology, it controls the switching state of the IGBT module, generates reactive compensation current synchronized with the grid voltage and offset by 90 degrees in phase, accurately offsets the reactive power of the load, and dynamically compensates for harmonic components. The ultimate goal is to only transmit active power on the grid side, achieving multiple objectives of power factor optimization, voltage stability, and harmonic suppression, ensuring efficient and stable operation of the power system.

Cooling method

  • Forced cooling (AF/Air Cooling)

  • Water Cooling

Heat dissipation mode:

Main Features

  • Advanced technology and comprehensive compensation: Integrating DSP+FPGA dual core control, instantaneous reactive power theory, and FFT harmonic calculation technology, it can not only automatically and continuously smooth adjust capacitive/inductive reactive power, but also dynamically compensate for harmonics, achieving integrated management of "reactive power & harmonics".

  • Dynamic precision and rapid response: response time<5ms, compensation current resolution 0.5A, supports stepless smooth compensation, effectively suppresses voltage flicker caused by impact loads (such as electric arc furnaces and frequency converters), and ensures stable operation of equipment.

  • Stable and reliable, suitable for outdoor use: adopting a dual power supply design, supporting seamless backup switching; Redundant design meets the operational requirements of N-2, with multiple protection functions (overvoltage, undervoltage, overcurrent, overheating, etc.) fully covering fault scenarios; IP44 outdoor protection level, able to withstand operating temperatures of -35 ℃~+40 ℃, humidity &le; 90%, and seismic intensity of VIII degrees, suitable for complex outdoor environments.

  • Efficient and environmentally friendly, with lower energy consumption: system power loss<0.8%, harmonic distortion rate THDi<3%, minimal pollution to the power grid; No additional transformer losses, balancing energy conservation and environmental protection needs.

  • Flexible adaptation and strong scalability: supports multiple operating modes such as constant reactive power, constant power factor, and constant voltage; Compatible with multiple communication protocols such as Modbus RTU and IEC61850; It can achieve multi machine parallel networking, multi bus comprehensive compensation, and modular design for easy expansion.

  • Easy to operate, maintenance tips: The device design takes into account usability, and attention should be paid to timely cleaning of the filter cotton. It is recommended to clean it at least once every two weeks to ensure heat dissipation and operational stability.

Technical Specifications

Name

Specification

Rated voltage

6kV±10%~35kV±10%

Assessment point voltage

6kV±10%~35kV±10%

Input voltage

0.9~ 1.1pu; LVRT 0pu(150ms), 0.2pu(625ms)

Frequency

50/60Hz; Allow short-term fluctuations

Output capacity

±0.1Mvar~±200 Mvar

Starting power

±0.005Mvar

Compensation current resolution

0.5A

Response time

<5ms

Overload capacity

>120% 1min

Power loss

<0.8%

THDi

<3%

Power supply

Dual power supply

Control power

380VAC, 220VAC/220VDC

Reactive power regulation mode

Capacitive and inductive automatic continuous smooth adjustment

Communication interface

Ethernet, RS485, CAN, Optical fiber

Communication protocol

Modbus_RTU, Profibus, CDT91, IEC61850- 103/104

Running mode

Constant device reactive power mode, constant assessment point reactive power mode, constant assessment point power factor mode, constant assessment point voltage mode and load compensation mode

Parallel mode

Multi machine parallel networking operation, multi bus comprehensive compensation and multi group FC comprehensive compensation control

Protection

Cell DC overvoltage, Cell DC undervoltage, SVG overcurrent, drive fault, power unit overvoltage, overcurrent, overtemperature and communication fault; Protection input interface, protection output interface, abnormal system power supply and other protection functions.

Fault handling

Adopt redundant design to meet N-2 operation

Cooling mode

Water cooling/Air cooling

IP degree

IP30(indoor); IP44(outdoor)

Storage temperature

-40℃~+70℃

Running temperature

-35℃~ +40℃

Humidity

<90% (25℃), no condensation

Altitude

<=2000m (above 2000m customized)

Earthquake intensity

Ⅷ degree

Pollution level

Grade IV

Specifications and dimensions of 6kV outdoor products 

Air cooling type:

Voltage class(kV)

Rated capacity(Mvar)

Dimension
W*D*H(mm)

Weight(kg)

Reactor type

6

1.0~6.0

5200*2438*2560

6500

Iron core reactor

7.0~12.0

6700*2438*2560

6450~7000

Air core reactor

Water cooling type

Voltage class(kV)

Rated capacity(Mvar)

Dimension
W*D*H(mm)

Weight(kg)

Reactor type

6

1.0~15.0

5800*2438*2591

7900~8900

Air core reactor

Note:
1. Capacity (Mvar) refers to the rated regulation capacity within the dynamic regulation range from inductive reactive power to capacitive reactive power.
2. The air core reactor is used for the equipment, and there is no cabinet, so the placement space needs to be planned separately.
3. The above dimensions are for reference only. The company reserves the right to upgrade and improve the products. The product dimensions are subject to change without notice.

Application scenarios

  • Power system: Adapt to various levels of distribution networks, stabilize grid voltage, balance three-phase systems, reduce power losses, and enhance power transmission capacity.

  • In the field of heavy industry: metallurgy (electric arc furnace, induction furnace), mining (hoist), ports (crane) and other scenarios, compensating for reactive power and harmonics of impact loads, and suppressing voltage flicker.

  • Petrochemical and manufacturing industry: Provide compensation for asynchronous motors, transformers, thyristor converters, frequency converters and other equipment, improve power quality, and ensure production continuity.

  • In the field of new energy, wind farms, photovoltaic power stations, etc. are used to alleviate power fluctuations caused by intermittent power generation and ensure stable grid connected voltage.

  • Transportation and urban construction: electrified railways (traction power supply system), urban rail transit (elevators, cranes), solving negative sequence and reactive power problems; Urban distribution network renovation to enhance power supply reliability.

  • Other scenarios: outdoor working conditions that require reactive power compensation and harmonic control, such as lighting equipment, welding machines, resistance furnaces, quartz melting furnaces, etc.

Documentation Resource Library
Restricted
6 to 35kV Static Var Generator(SVG) Brochure
Brochure
English
Consulting
Consulting
Restricted
Power compensation equipment SVG/FC/APF Catalog
Catalogue
English
Consulting
Consulting
FAQ
Q: How to choose the appropriate capacity for SVG?
A:

SVG capacity selection core: steady-state calculation & dynamic correction. Basic formula: Q ₙ=P × [√ (1/cos ² π₁ -1) - √ (1/cos ² π₂ -1)] (P is active power, power factor before compensation, target value of π₂, often requires ≥ 0.95). Load correction: impact/new energy load x 1.2-1.5, steady-state load x 1.0-1.1; High altitude/high temperature environment x 1.1-1.2. New energy projects must comply with standards such as IEC 61921 and ANSI 1547, with an additional 20% low-voltage ride through capacity reserved. It is recommended to leave 10% -20% expansion space for modular models to avoid compensation failure or compliance risks caused by insufficient capacity.

Q: What are the differences between SVG, SVC, and capacitor cabinets?
A:

What are the differences between SVG, SVC, and capacitor cabinets?

The three are the mainstream solutions for reactive power compensation, with significant differences in technology and applicable scenarios:

Capacitor cabinet (passive): The lowest cost, graded switching (response 200-500ms), suitable for steady-state loads, requires additional filtering to prevent harmonics, suitable for budget limited small and medium-sized customers and entry-level scenarios in emerging markets, in compliance with IEC 60871.

SVC (Semi Controlled Hybrid): Medium cost, continuous regulation (response 20-40ms), suitable for moderate fluctuating loads, with a small amount of harmonics, suitable for traditional industrial transformation, in compliance with IEC 61921.

SVG (Fully Controlled Active): High cost but excellent performance, fast response (≤ 5ms), high-precision stepless compensation, strong low-voltage ride through capability, suitable for impact/new energy loads, low harmonic, compact design, in line with CE/UL/KEMA, is the preferred choice for high-end markets and new energy projects.

Selection core: Choose capacitor cabinet for steady-state load, SVC for moderate fluctuation, SVG for dynamic/high-end demand, all of which need to match international standards such as IEC.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 30000m² Total staff: Highest Annual Export(usD): 100000000
Workplace: 30000m²
Total staff:
Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Robot
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

Related Solutions

Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.