• Grounding/earthing TransformerUp to 36kV
Grounding/earthing TransformerUp to 36kV
discuss personally
Model
JDS/36/3000
Basic info
Brand ROCKWILL
Model NO. Grounding/earthing TransformerUp to 36kV
Rated voltage 36kV
Rated normal current 3000A
Rated frequency 50/60Hz
Series JDS
Product Detail

Description

This grounding transformer, suitable for systems up to 36kV, is a specialized electrical device. It creates an artificial neutral point in power grids, playing a crucial role in grounding protection. By effectively handling single - phase ground faults, it ensures the stable operation of medium - voltage power systems, whether in urban distribution networks or industrial power setups.

Feature

  • Voltage Adaptability:Designed for up to 36kV systems, it matches the common voltage levels of medium - voltage power grids, ensuring wide - ranging applicability.

  • Fault Handling:Efficiently suppresses arc - grounding overvoltages during single - phase ground faults. It helps reduce ground fault currents, minimizing damage to power grid equipment and enhancing system reliability.

  • Robust Construction:Built with high - quality materials like premium magnetic cores and durable windings. The enclosure is sturdy, resisting harsh environmental factors such as moisture and dust, ensuring long - term stable performance.

  • Safety Enhancement:Provides a reliable neutral grounding solution, preventing abnormal voltage fluctuations and equipment insulation damage, thus safeguarding the safety of the entire power grid and connected electrical devices.

Main technical parameter

Note: This parameter table is for reference. We can offer customize production tailored to client specifications.

Scope of Application

Suitable for scenarios with varying capacities and voltage levels.

  • 35kV and Above Distribution Networks: Transformer windings typically adopt a star (Y) connection with an accessible neutral point, eliminating the need for grounding transformers.

  • 6kV and 10kV Distribution Networks: Transformer windings mostly use delta (Δ) connections without accessible neutral points, requiring grounding transformers to provide a neutral point.

Special Scenarios: When system unbalanced voltage is high, Z-type transformers can meet measurement requirements through balanced design of their three-phase windings. When system unbalanced voltage is low (e.g., fully cable-based networks), the neutral point of Z-type transformers must generate an unbalanced voltage of 30-70V to satisfy measurement criteria.

Purpose and Function: Provides a return path for fault currents, ensuring safety and stability during ground faults.

Operating Principle During Faults: During a ground fault, fault current flows through the transformer’s neutral point. The counteracting magnetic flux generated by reverse current neutralizes impedance.

Voltage and Current Ratings: Rated voltage matches the system’s line voltage. Capable of withstanding maximum fault currents for up to 30 seconds.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!