500kV 550kV Single-phase Oil-Immersed Air-Cooled Autotransformer with Three Windings and No Excitation

  • 500kV 550kV Single-phase Oil-Immersed Air-Cooled Autotransformer with Three Windings and No Excitation

Key attributes

Brand ROCKWILL
Model NO. 500kV 550kV Single-phase Oil-Immersed Air-Cooled Autotransformer with Three Windings and No Excitation
Rated voltage 550kV
Rated frequency 50/60Hz
Series ODFS

Product descriptions from the supplier

Description

Description:

The 500kV/550kV Single-Phase Oil-Immersed Air-Cooled Autotransformer with Three Windings and No Excitation is engineered for ultra-high voltage transmission networks requiring exceptional reliability and efficiency. Its oil-immersed air-cooled (ONAN) design ensures effective heat dissipation under continuous operation, while the three-winding configuration provides flexible power allocation and system interconnection capabilities. The no-excitation voltage regulation mechanism eliminates the complexity of on-load tap changers, reducing maintenance needs and enhancing operational stability. Ideal for core grid substations, this transformer delivers robust performance in demanding environments with minimal lifecycle costs.

Product Characteristics:

  • Rational Structural Design:Leveraging advanced modern calculation technologies, the transformer’s structure is optimized through in-depth analysis of its electrical, magnetic, mechanical, and thermal properties. This ensures structural integrity and performance synergy across all operational conditions.

  • Advanced Performance Indicators:Compliant with international IEC standards, the product can also be tailor-made to meet specific customer requirements. Its partial discharge (PD) level is significantly lower than the limit specified in IEC 60076-3, delivering exceptional electrical performance and operational stability.

  • High Operational Reliability:Reliability is guaranteed by comprehensive analysis of electrical, magnetic, mechanical, and thermal characteristics. Combined with a scientific insulation structure, optimized ampere-turn distribution, and efficient cooling system, it boasts strong resistance to overvoltage and short-circuit currents, eliminating the risk of local overheating during long-term operation.

  • Premium Configured Accessories:Equipped with high-quality accessories, the transformer offers superior user experience. It features an aesthetically pleasing appearance, reliable leak-proof design, and supports maintenance without tank disassembly—achieving a near maintenance-free operation mode that reduces operational costs and workload.

Technical Parameters:

Among these, some autotransformers cover non-standard voltage levels including 121kV, 132kV, 138kV, 200kV, 225kV, 230kV, 245kV, 275kV, 330kV, 345kV, 400kV and 756kV, We also provide customization services.

500kV 100MVA~484MVA Single-phase, Double-winding Power Transformer with Off-circuit Tap-changer

Rated capacity

(kVA)

Voltage combination and tapping range

Vector group

Energy consumption class Ⅰ

Energy consumption class Ⅱ

Energy consumption class Ⅲ

Short-circuit impedance

(%)

HV tapping range

(%)

LV (kV)

No-load loss

(kW)

On-load loss

(kW)

No-load loss

(kW)

On-load loss

(kW)

No-load loss

(kW)

On-load loss

(kW)

100

500/√3

525/√3

535/√3

550/√3


13.8;15.75

Ii0

34

203

40

203

49

214

14

120

15.75;18;20

39

234

46

234

56

247

200

15.75;18;20;24

63

342

74

342

91

361

223

18

68

371

81

371

99

391

240

18;20;24

72

392

85

392

105

413

260

18;20

77

414

91

414

112

437

380

24;27

102

549

121

549

149

580

16 or 18

400

106

570

125

570

154

601

410

108

581

128

581

158

613

484

123

657

145

657

178

694

Note: Transformers with various special parameters and performance can be manufactured according to customer requirements.

500kV 120MVA~1170MVA Three-phase, Double-winding Power Transformer with Off-circuit Tap-changer

Rated capacity (kVA)

Voltage combination and tapping range

Vector group

Energy consumption class Ⅰ

Energy consumption class Ⅱ

Energy consumption class Ⅲ

Short-circuit impedance (%)

HV tapping range(%)

LV (kV)

No-load loss(kW)

On-load loss(kW)

No-load loss(kW)

On-load loss(kW)

No-load loss(kW)

On-load loss(kW)

120

500

525

550

13.8;15.75

YND11

41

356

49

356

60

375

14

160

50

441

59

441

72

466

240

69

599

81

599

100

632

300

13.8;15.75;18

80

707

94

707

116

746

370

15.75;18;20

94

810

111

810

136

855

400

18;20;24

96

855

114

855

140

903

420

15.75;18;20

102

860

120

860

148

907

14 or 16

480

15.75;18;20

110

954

130

954

160

1007

600

15.75;18;20;24

143

1202

169

1202

208

1268

720

18;20;24

168

1382

198

1382

244

1458

750

20;22

173

1422

205

1422

252

1501

16 or 18

780

22

176

1467

208

1467

256

1549

860

190

1575

224

1575

276

1663

1140

27

237

1949

280

1949

344

2057

1170

242

1980

286

1980

352

2090

Note: Transformers with various special parameters and performance can be manufactured according to customer requirements.

500kV 120MVA~1170MVA Three-phase, Double-winding Power Transformer with Off-circuit Tap-changer

Rated capacity

(kVA)

Voltage combination and tapping range

Vector group

Energy consumption class Ⅰ

Energy consumption class Ⅱ

Energy consumption class Ⅲ

Short-circuit impedance

(%)

HV

(kV)

MV tapping range

(kV)

LV

(kV)

No-load loss

(kW)

On-load loss

(kW)

No-load loss

(kW)

On-load loss

(kW)

No-load loss

(kW)

On-load loss

(kW)

120

600/

√3

625/

√3

650/

√3


230/√3

230/√3

±2×2.5%

242/√3

±2×2.5%


35

36

37

38.5

63

66

Iaoi0

28

207

33

207

40

219

HV-MV 12

HV-LV

34 ~ 38

MV-LV

20 ~ 22

167

33

248

39

248

48

261

250

47

333

55

333

68

352

334

58

428

68

428

84

451

400

66

491

78

491

96

518

120

28

221

33

221

40

233

HV-MV12

HV-LV

42 ~ 46

MV-LV

28 ~ 30

167

33

261

39

261

48

276

250

47

356

55

356

68

375

334

58

459

68

459

84

485

400

66

522

78

522

96

551

120

28

221

33

221

40

233

HV-MV 14 ~ 15

HV-LV

42 ~ 46

MV-LV

28 ~ 30

167

33

261

39

261

48

276

250

47

356

55

356

68

375

334

58

459

68

459

84

485

400

66

522

78

522

96

551

 

Note: Transformers with various special parameters and performance can be manufactured according to customer requirements.

Normal Service Conditions

(1) Altitude:  ≤1000m;

(2) Ambient temperature:Maximum temperature: +40℃;Maximum monthly average temperature: +30℃;Maximum yearly average temperature: +20℃;Minimum temperature: -25℃.

(3) Power supply: approximate sinusoidal wave, three-phase symmetrical approximately

(4) Installation site: indoor or outdoor, without the obvious contamination.Note: The transformer used in special conditions should be specified when ordered.

FAQ
Q: For 500kV/550kV no-excitation autotransformers, how to balance operational stability and maintenance convenience?
A:
Its design achieves a perfect balance through two aspects: On the stability side, the no-excitation voltage regulation structure simplifies internal components, reducing failure points; the scientific insulation design and strict compliance with IEC standards further enhance operational reliability. On the maintenance side, the oil-immersed air-cooled system adopts mature leak-proof technology, and the accessories support maintenance without tank disassembly. This combination ensures long-term stable operation while lowering daily maintenance costs and workload for users.
Q: What makes the 500kV/550kV single-phase oil-immersed air-cooled autotransformer suitable for large-scale power grids?
A:
As a key UHV equipment, it integrates three-core advantages tailored for large grids: First, the oil-immersed air-cooled design ensures efficient heat dissipation, adapting to long-term high-load operation. Second, the three-winding structure realizes flexible voltage conversion between 500kV/550kV and lower levels, optimizing power transmission efficiency. Third, it has strong overvoltage and short-circuit resistance, maintaining grid stability even in complex working conditions. These features make it a core component for long-distance and large-capacity power transmission.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

Related Solutions

Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.