• PQpluS Series modular battery energy storage unit
PQpluS Series modular battery energy storage unit
discuss personally
Model
PQpluS-size2
PQpluS-size1
Basic info
Brand RW Energy
Model NO. PQpluS Series modular battery energy storage unit
Rated voltage 400V
Rated Output Rating 360KW
Series PQpluS Series
Product Detail

Overview

Our grid is transforming. A commercial and industrial (C&I) customer can also be an electricity producer as well as a consumer (i.e., a prosumer). Therefore, a battery energy storage system is becoming integral to the changing relationship between utilities and their customers. PQpluS enables its users to reduce energy costs and makes the network more resilient while improving the power system's efficiency, reliability, and availability. It helps the electricity consumer by actively managing the timing and profile of their energy usage through the following functions:

Peak shaving
The energy consumption pattern in the C&I segment follows a cycle of peak and low load conditions. Peak load periods coinciding for several consumers can lead to a shortage of power supply. To avoid such situation, utilities often charge premium prices for energy consumed during peak hours, resulting in high energy costs to the consumer. PQpluS is used for peak demand shaving, resulting in a uniform load distribution around the complete load cycle and saving penalties for the consumer.

Easier use of self-generation and time-of-use tariffs

PQpluS units offer multiple ways for consumers to reduce their electricity bills without requiring changes in consumption habits. In regions with dynamic time-of-use pricing, they can charge their batteries either from their rooftop solar PV system or from the grid during off-peak hours and then discharge as needed during peak hours, thereby obtaining the cost savings of demand shifting without actually changing the times when they use energy.

Facilitating connection of renewable resources

Limited predictability is a critical drawback of green energy sources such as wind and solar plants. Due to its unpredictable behaviour, a significant renewable energy source imposes an additional burden on the network operators. The PQpluS units can minimize the impact of renewables on the network by offering a “buffer” that can absorb excess power and release it when the output from these sources falls short.

Integration of fast EV chargers

PQpluS units accompany fast EV chargers in remote places along highways where grid operators cannot offer enough power connection for ultra-fast or fast charging service. With PQpluS, you can avoid or postpone grid investment while still using high-power chargers.

Technology parameters

 

Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High Voltage Electrical Apparatus/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Documents
Public.
modular battery energy storage unit Data sheet
White paper English
PDF
Related Products
Related Knowledges
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the
Echo
09/02/2025
Working Principle and Arc Extinction Mechanism of Magnetic Blowout Device in DC Circuit Breakers
Working Principle and Arc Extinction Mechanism of Magnetic Blowout Device in DC Circuit Breakers
The arc extinguishing system of a DC circuit breaker is crucial for the safe operation of equipment, as the arc generated during current interruption can damage contacts and compromise insulation.In AC systems, the current naturally passes through zero twice per cycle, and AC circuit breakers take full advantage of these zero-crossing points to extinguish the arc.However, DC systems lack natural current zero crossings, making arc extinction significantly more difficult for DC circuit breakers. T
Felix Spark
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!