• 100 kVA Single Phase Pole Mounted Transformer
100 kVA Single Phase Pole Mounted Transformer
discuss personally
Model
DR11-100/10
Basic info
Brand Vziman
Model NO. 100 kva Single Phase Pole Mounted Transformer
Rated capacity 100kVA
Series Single Phase Pole Mounted Transformer
Product Detail

Product Overview

A professional distribution transformer manufacturer with 10 years of expertise, specializes in single-phase pole-mounted transformers for urban and rural power distribution. Designed for 11kV, 12.4kV, 13.2kV, 13.8kV, and 34.5kV input voltages, these transformers deliver outputs such as 240/480V and 120/240V, complying with IEEE C57, ANSI C57, and IEC 60076 standards.

Leading Technological Advantages

  • Enhanced Lightning Resistance: Unique winding technology minimizes surge damage.

  • Superior Mechanical Strength: Low magnetic leakage design with 45° full-oblique step-laminated iron core structure resists short circuits.

Shell & Construction

Precision Manufacturing:

  • Mitsubishi laser cutting and CNC punching ensure mm-level accuracy.

  • ABB robotic welding with laser detection achieves a 99.99998% leak-proof rate.

  • Durable Coating: Electrostatic spray paint offers 50+ years of corrosion resistance (100h salt spray test, hardness ≥0.4).

  • Fully Sealed Design: Cylindrical structure with self-sealing manual pressure relief valve (ANSI-compliant), NEMA-standard hanger brackets, and 30+ year maintenance-free operation.

Core Components

Iron Core

  • High-quality cold-rolled grain-oriented silicon steel sheets from Baowu Steel (China), with mineral oxide insulation.

  • Precision cutting and stacking reduce no-load current, losses, and noise.

Windings

  • Low Voltage: High-grade cable paper-wrapped wires.

  • High Voltage: Polyurethane enamelled round copper wires.

  • Interlayer insulation with dot-adhesive paper ensures coil stability and insulation resistance.

Premium Materials

  • Silicon steel sheets: Baowu Steel Group.

  • Oxygen-free copper: Chinese high-purity grade.

  • Transformer oil: CNPC Kunlun 25# premium oil.

Additional Features

  • High-strength polymer or porcelain low/high-voltage bushings.

  • Ring-type full-copper tinned terminals.

  • Integrated current-limiting fuses and arresters for surge protection.


Product parameters:

  • Capacity: 100kVA 

  • Rated voltage: 13.8kV, 34.5kV

  • Maximum operating voltage (kV) 38.5kV

  • Conditions of use:

  • The temperature:
    Maximum daily temperature (℃) : 40; Minimum daily temperature (℃) : -25; Maximum daily temperature difference (K) : 25; Average temperature of the hottest month (℃) : 30; Maximum annual average temperature (℃) : 20; Average daily relative humidity (≤%) : 95; Average monthly relative humidity (≤%) : 90 

  • Altitude (≤m) : 1000

  • Solar radiation intensity (W/cm2) : 0.1

  • Maximum ice thickness (mm) : 10

  • 10m high from the ground, maintain 10min average maximum wind speed (m/s) : 35

  • Ground horizontal acceleration (M/S2) : 2

  • Installation place: outdoor; 8. Pollution grade: ⅲ

image.png

Ordering instructions:

  • Main parameters of transformer (voltage, capacity, loss and other main parameters) .

  • Transformer use environment (altitude, temperature, humidity, place, etc) .

  • Other customized requirements (tap switch, color, oil pillow, etc) .

  • The minimum order quantity is 1 set, global delivery within 7 days .

  •  The normal delivery period is 30 days, with fast delivery worldwide .

What are the advantages of a single-phase pole-mounted transformer?

  • High Efficiency:Utilizes premium winding materials and advanced manufacturing techniques to achieve superior energy conversion efficiency, reducing operational losses.

  • Low Loss Performance:Constructed with high-grade silicon steel sheets and precision processes, minimizing no-load and load losses for enhanced energy savings and environmental friendliness.

  • Extended Service Life:Premium materials and rigorous manufacturing standards ensure prolonged durability, reducing replacement needs over the product lifecycle.

  • Low Noise Operation:Optimized core and coil design significantly reduces operational noise, making it ideal for noise-sensitive environments like urban areas or commercial buildings.

  • Reliable Performance:Oil-immersed design offers excellent cooling and insulation capabilities, ensuring stable operation in high-power, high-voltage applications.

  • Enhanced Fire Safety:Despite oil-based insulation, modern designs incorporate multi-layer protective measures (e.g., pressure relief valves, fire-retardant coatings) to mitigate risks.

  • Robust Environmental Adaptability:Engineered to withstand harsh conditions, including extreme temperatures, high humidity, and rugged terrain, for versatile deployment.

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!