• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


38.5kV 44kV 45kV 46kV Sine Curare Non Gas Mensa IEE-Business Originalis Fabricator

  • 38.5kV 44kV 45kV 46kV Maintenance-Free Environmental Protection no gas switchboard panel Original Manufacturer

Attributa principalia

Marca ROCKWILL
Numerus Modeli 38.5kV 44kV 45kV 46kV Sine Curare Non Gas Mensa IEE-Business Originalis Fabricator
Votum nominatum 12kV
Frequenta nominata 50/60Hz
Series EcoRing

Descriptiones productorum a fornitori

Descriptio

Descriptio

Armariolum anulare gas insulatum pro rete medio-voltale, quod tensiones 38.5kV 44kV 45kV 46kV sustinet, est dispositivum distributionis medii voltalis admodum efficax pro retibus intelligentibus modernis. Integrat technologiam gas insulantem amicam ambiente cum designo non indigente cura, efficaciter substituens instrumenta gas insulata traditionalia, quae in gasa alta-GWP (Potentiali Calorifico Globale) confidunt. Quasi pars centralis in systematibus distributionis electricitatis, late usurpatur in retibus distributionis urbani, in parvis industrialibus et in complexibus commercialibus—praebens supportum electricitatis stabilis, securus et paucocarbonis usui finali. Per optimisationem structurae camerae gasorum et adoptionem materialium obturandi praestantium, eliminat necessitatem regularis replenitionis gasorum et inspectionis componentium, dum gas amicum ambiente normas internationales paucocarbonis adimplet, congruens cum scopis globalibus conservationis energiae et reductionis emissionum.

Praestantia

  • Duas Praestantias Amicae Ambiente & Non Indigentis Cura:Adoptat gas amicum ambiente (congruentem cum normis amicis ambiente) ut polluti ambientes vitetur; camera gasorum hermetica et componentia resistentia usui longinquam operationem sine cura permittunt, minuendo costus operationis et curationis.

  • Altam Securitatem & Stabilitatem Operationis:Equipatum technologia insulantia gasorum admodum praestanti, habet resistenciam fortissimam contra humiditatem, pulverem et corrosionem; functiones protectionis overvoltage et circuiti brevis integratae stabilitatem supply power etiam in mediis operativis asperis certificant.

  • Designum Compactum pro Installatione Flexibili:Structura compacta spatium installationis servat, id aptum faciens pro locis angustis sicut stationibus electricitatis subterraneis urbanis et officinis industrialibus; modulis combinabilibus ad diversa dispositionum retorum distributionis opus respondet.

  • Monitorem Intelligentem pro Gestionis Praedictiva:Systema monitorum online intelligentium optionale pressionem gasorum, temperaturam et statum operationis in tempore reali sequitur; praemonitiones pro conditionibus abnormalibus mittit, iuvans utentes ut curationem praedictivam et efficientiam gestionis retorum improve.

Parametri Producti

Classes tensionum aliquorum horum switchgear amicorum ambiente includunt 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV et 69kV. et customizatio est disponibilis.

Generale

Unitas

Parametri

Tensio Nominale

kV

12

Frequencia Nominale

Hz

50

Tensio Sustinendi ad Frequencia

V/min

42/28

Tensio Impulsus Fulminis

kV

75/85

Duratio Arcus

s

1

Nivellus Protectionis Componentum Primarium (excluso armario mensurae)

IP67

Nivellus Protectionis Armarii

IP4X

Nivellus Protectionis Cameram Isolationis

IP2X

Tensio Fontis Operativi

V

DC: 24 48 110 220

AC: 110 220

Campus applicandus:

Projecta reparationis et renovationis distributionum urbanarum et rusticarum   

Systemata adiutoria pro stationibus electricitatis novae  

Systemata distributionis electricitatis in praediis industrialibus  

Complexus commerciales et aedificia alta  

Systemata suppeditationis electricitatis pro transitu ferroviario

FAQ
Q: Num aer siccus medium insulationis commune pro armariis ambiens conservantis 12kV?
A:
Sic, aer siccus est unum ex communissimis mediis insulatoribus pro armariis ambiens-friendly 12kV. Is non venenosus, non effector domorum caloris, parvi costi, et facilis praeparandi. Requisitum clavem pro aere sicco in armariis 12kV est punctum rosi ≤ -40℃ (etiam ≤ -50℃ in scenariis summae demandae) ut insulativa perficiantur. Multi fabricantes principales (sicut Guangyun Electric, Kangjin Electric) aerem siccum in suis productis RMU ambiens-friendly 12kV utuntur.
Q: Quid est differentia inter N2 et N2/CO2 mixtura in armariis ambiens amicis usitatis?
A:
Nitrogen (N2) habet proprietates chemicas stabiles, non efficit effectum hothouse, et resistit bene frigoris (non liquefit in regionibus alpinis), sed eius insulatio est moderata. Mixtura N2/CO2 regit insulatio et dissipationem caloris per optimisationem rationis mixtionis. Tamen CO2 est gas hothouse, quod limitat eius applicationem in scenariis maxime ecologicis. N2 est magis idoneus ad scenarii unius insolationis, mixturae vero N2/CO2 utuntur in scenariis requirientibus aequilibrium inter insulatio et dissipatio caloris.
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
  • Quid est Differentia Inter Transformatores Rectificatores et Transformatores Potentiae?
    Quid est transformator rectificans?"Conversio potentiae" est terminus generalis qui conversionem, inversionem et conversionem frequentiae comprehendit, inter quas conversio praecipue usitatissima est. Apparatus rectificans convertit potentiam AC input in DC output per rectificationem et filtrationem. Transformator rectificans servit ut transformator alimentationis pro talibus apparatibus rectificantibus. In applicationibus industrialibus, plerumque alimenta DC obtinentur per combinandum transfor
    01/29/2026

Solutiones Relatae

  • Design Solution of 24kV Siccum Aera Insulatum Ring Main Unit
    Combinatio Solidi Insulationis Adiuvantis + Insulationis Aereae Siccae repraesentat directionem pro RMU 24kV. Per requirementa insulationis cum compactitate equilibrata et adiuvante solidum insulationis, testes insulationis sine magnificatione significativa dimensionum inter phasos et inter phasos et terram transigi possunt. Inclusio columnae pole solidificat insulationem pro interruptore vacuo et conductoribus eius coniunctis.Maintinendo spatium phasorum exiens 24kV ad 110mm, intensitas electri
    08/16/2025
  • Optimizatio Design Schematum pro Unitate Circulorum Principalium Aere Insulata 12kV ad Minuendam Probabilitatem Disruptionis Emissionis
    Cum celeri progressus industriae electricitatis, conceptus ecologicus de carbonis minore, energiae servanda, et conservatione ambientis profundissime integratus est in designum et fabricam productorum electricorum pro distributione et generatione electricitatis. Unitas Distributiva Circuli (RMU) est dispositivum electricum clavem in retibus distributionis. Securitas, conservatio ambientis, fides operativa, efficacia energetica, et oeconomia sunt tendentiae inevitabiles in eius progressu. RMUs tr
    08/16/2025
  • Analyse communium problematum in unitatibus principali circuitu isolatis gas 10kV (RMUs)
    Introductio:​​RMUs insulati gaseis 10kV sunt amplissime usitati propter multas suas utilitates, sicut quod sint perfecte clausi, habeant excellentem insulativam qualitatem, non requirant maintenance, sint compacti, et praebent installationem flexibilem et commodam. In hoc stadio, paulatim facti sunt nodus criticus in rete distributionis urbano anulari et iocabuntur partem significativam in systemate distributionis electricitatis. Difficultates in RMUs insulatis gaseis possunt graviter impingere
    08/16/2025
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum