Model
YH20W1-600/1380
Basic info
Brand ROCKWILL
Model NO. 330 - 1000kV Composite - Housed Metal Oxide Surge Arresters
Rated voltage 420kV
Rated frequency 50/60Hz
Series YH20W
Product Detail

Description

330 - 1000kV Composite - Housed Metal Oxide Surge Arresters are critical protective devices engineered for ultra - high - voltage (UHV, 330kV to 1000kV) power transmission and transformation systems. Deployed in UHV substations, long - distance transmission lines, and alongside core equipment (e.g., transformers, gas - insulated switchgear), these arresters utilize advanced composite (typically silicone rubber) housings integrated with high - performance metal oxide varistors (MOVs). Their primary role is to suppress transient overvoltages triggered by lightning strikes, switching operations, or grid faults. By diverting excessive surge currents to the ground and maintaining stable voltage levels during normal operation, they safeguard the reliability of 330 - 1000kV UHV power grids, preventing equipment damage, unplanned outages, and ensuring the seamless transmission of large - scale electrical energy.

Features

  • UHV Voltage Range Adaptability
    Tailored for 330kV to 1000kV UHV systems, with rated voltages precisely matching the stringent requirements of ultra - high - voltage grids. Efficiently limits overvoltages under extreme surge conditions (e.g., direct lightning strikes on transmission lines), ensuring the stability of large - scale cross - regional power transmission networks.

  • Composite Housing Advantages
    The composite (silicone rubber) enclosure delivers multiple benefits: excellent hydrophobicity resists pollution and moisture accumulation, reducing flashover risks in high - humidity or polluted environments (e.g., industrial zones); high mechanical strength withstands strong winds, seismic forces, and thermal cycling in diverse climates; lightweight design simplifies transportation and installation compared to traditional porcelain housings, cutting project costs.

  • Modular & Scalable Design
    Available in modular configurations, enabling flexible assembly to meet different UHV grid protection needs (e.g., single - phase or three - phase setups). Scalable for future grid upgrades, ensuring compatibility with evolving 330 - 1000kV system architectures without full replacement.

  • Low Maintenance & Long Service Life
    Composite housing resists aging, UV degradation, and chemical corrosion, reducing maintenance frequency. Built - in thermal stability and MOV self - healing capabilities (to an extent) extend the service life to 20 + years, minimizing lifecycle costs and ensuring continuous protection for UHV infrastructure.

  • Compliance with International Standards
    Adheres to strict global standards (e.g., IEC 60099 - 4, IEEE C62.11 for UHV arresters). Undergoes rigorous testing for impulse current withstand, thermal cycling, and environmental endurance, guaranteeing safe, reliable operation in harsh UHV grid conditions (e.g., high altitude, extreme temperatures).

  • Enhanced Surge Current Handling
    Effectively diverts ultra - large surge currents (from lightning or switching transients) to the ground, limiting overvoltages to levels that protect expensive UHV equipment (e.g., transformers, circuit breakers). Reduces the risk of cascading failures, enhancing the overall resilience of 330 - 1000kV power systems.

  • Intelligent Monitoring Compatibility
    Many models support integration with smart grid monitoring systems. Equipped with sensors to track leakage current, temperature, and operating status in real - time. Enables predictive maintenance, allowing utilities to detect potential faults early and avoid unplanned outages in critical UHV networks.

parameters

Model 

Arrester

System

Arrester Continuous Operation

DC 1mA

Switching Impulse

Nominal Impulse

Steep - Front Impulse

2ms Square Wave

Nominal

Rated Voltage

Nominal Voltage

Operating Voltage

Reference Voltage

Voltage Residual (Switching Impulse)

Voltage Residual (Nominal Impulse)

Current Residual Voltage

Current - Withstand Capacity

Creepage Distance

kV

kV

kV

kV

kV

kV

kV

A

mm

(RMS Value)

(RMS Value)

(RMS Value)

Not Less Than

Not Greater Than

Not Greater Than

Not Greater Than

20 Times






(Peak Value)

(Peak Value)

(Peak Value)

(Peak Value)


YH20W1-828/1620W

828

1000

638

1114

1460

1620

1782

8000

33000

YH20W1-600/1380

600

750

462

810

1135

1380

1462

2500

28000

YH20W1-648/1491

648

750

498

875

1226

1491

1578

2500

28000

YH20W1-420/1006

420

500

318

565

825

1006

1106

2000

18900

YH10W1300/727

300

330

228

425

618

727

814

1200

12600

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the
Echo
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!