• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


40.5kV Solid Insulated Switchgear/ Ring Main Unit Unitas IEE-Business

  • 30kV 35kV 38.5kV 40.5kV Solid Insulated Switchgear/ Ring Main Unit

Attributa principalia

Marca ROCKWILL
Numerus Modeli 40.5kV Solid Insulated Switchgear/ Ring Main Unit Unitas IEE-Business
Votum nominatum 40.5kV
Frequenta nominata 50/60Hz
Series FYG

Descriptiones productorum a fornitori

Descriptio
Descriptio

40.5kV Solid Insulated Switchgear:Series FYG solidi insulata apparatu apta est ad systema distributionis medii voltage cum currente nominale 630A/1250A. Haec est fidelior quam SF6 ring main unit, et magis apta ad latiorem applicationem standardum GB et IEC.

Feature

  • Performantia insulativa solida adaptata ad 40.5kV high voltage: Adoptat materiales insulativi solidos altae fortitudinis sicut resina epoxy, cum designo insulativo optimizato pro gradu 40.5kV high-voltage. Haec praebet stabilem fortitudinem insulativam, non affectam a factoribus environmentalibus sicut humiditas et contaminatio, efficaciter reducens pericula flashover et breakdown sub alto voltage, et securans operationem fidelem systematis distributionis alti voltage.

  • Designus sine gas ex omnibus conditionibus amicus ecologiae: Abandonat gases greenhouse sicut SF₆, fundamentaliter eliminans pericula environmentalia et operationis/maintenanceis causata per effugium gas. Haec conformatur regulis environmentalibus internationalibus et requirementibus constructionis green power grid, et est specialiter apta ad scenaria distributionis alti voltage sensibilia ad protectionem environmental, sicut zonas protectionis ecologicae et areas core urbis.

  • Structura compacta adaptionis alti voltage: Combinat crustam metallicam clausam cum dispositione modulare, significanter reducens volumen dum satisfacit distantiis insulativis alti voltage 40.5kV. Haec occupat spatium solo 60%-70% equipmenti traditionalis, faciens id aptum ad loca distributionis alti voltage restricta spatiis sicut substationes et magnae areae industrialis, simplicans dispositiones installationis.

  • Mechanismi multis protectionis alti voltage: Equipatur interlockis mechanicis et electricis specificis alti voltage ad strictam preventionem actionum periculosarum sicut operatio on-load et incorrecta grounding; crusta metallica totaliter clausa protegit campos electricos alti voltage, cum displayo vivo alti voltage et monitoring statu grounding, comprehensiviter securans operationem et maintenance in environmentis alti voltage.

  • Characteristica longaevitatis et paucitatis maintenance: Materiales insulativi solidi habent excellentes proprietates anti-aging et corrosion-resistant; componentes core sunt totaliter isolati ab exteriore, reducens pericula causata per arcus alti voltage et erosionem environmental. Haec attingit operationem sine maintenance plusquam 20 annos, significanter minuens costum totius vitae-cycli equipmenti alti voltage.

  • Compatibilitas distributionis alti voltage flexibilis: Supportat multos modos wiring alti voltage sicut rete anularis, dualis supply, et type radialis, et potest coniungi sine interruptione cum 40.5kV transformers, cable branch boxes, et alia equipment. Haec adapta diversis necessitatibus distributionis alti voltage in urbibus, magnis industriis, stationibus energiae novae, etc.

Conditiones environmentalis

  • Temperatura ambientalis: -25℃~+40℃;

  • Altitude: ≤1000m;

  • Humiditas relativa: media diaria ≤95%, media mensualis ≤90%;

  • Non sunt substantiae flammabiles et explosivas, non sunt chemicae corrosivae, vibratio frequens et gravis, et non est vibratio fortis.

FAQ
Q: Quomodo est stabilitas operationis armarii solidi et amici ambientis in mediis vel frigidis vel calidis?
A:
Habet excellentem stabilitatem operativam et amplitudinem temperaturarum applicabilium a -40℃ ad +70℃: 1) In mediis frigidis, materiae insulantes solidae non praebent fragilitatem a frigore nec degradantur in sua virtute insulantia propter nimiam frigiditatem; 2) In mediis calidis, resina epoxica optima habet bonam resistenciam ad calorem, et cum structura dissipativa caloris armarii (sicut radiatores), potest vitare senescens acceleratum strati insulantis. Notandum est ut evitetur operatio diuturna in ambientibus quae superant temperaturam nominalem.
Q: Quomodo gerere senectutem materialium insulatorum solidorum? An ulla pericula environmentalia sunt?
A:
Postquam materiae insulantes solidae (sicut resina epoxy) senescunt, oportet ut contactum facias cum fabricante pro substitutione vel renovatione armarii professionali, et ne ipsas dissecare conare. Materiae insulantes superfluae quae substitutae sunt, oportet eas tractari iuxta regulas conservationis: materiae sicut resina epoxy possunt comminui, recicli et reutilizari (sicut processae in plenariae aedificatoriae), aut subici incinerationi innoxiae, quae non generat substantias toxicas et nocivas nec habet pericula environmentalia manifesta.
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Quomodo Iudicentur Detectentur et Reparentur Defectus Nuclei Transformatoris
    1. Pericula, Causae et Species Multipuncti Defectus Terrae in Nucleo Transformatoris1.1 Pericula Multipuncti Defectus Terrae in NucleoIn operatione normali, nucleum transformatoris unice ad unum punctum terram tangere debet. In operatione, campi magnetici alternantes circuitus involvent. Propter inductionem electromagneticam, capacitatis parasiticae inter circuitus altae et bassae tensionis, inter circuitus bassae tensionis et nucleum, et inter nucleum et vas existunt. Circuitus electri sint per
    01/27/2026
  • Brevis Disputatio de Selectu Transformerum ad Terram in Stationibus Augendae Tensionis
    Brevis Disputatio de Selectu Transformatorum ad Terram in Stationibus Augendi TensionisTransformator ad terram, communiter "transformator ad terram" appellatus, sub conditione sine onere operatur durante normali operatione rete et supra onus durante defectibus short-circuit. Secundum differentiam in medio impletivo, communes species dividuntur in oleo-immersos et siccos; secundum numerum phasium, possunt classificari in triphasicos et uniphasicos transformatores ad terram. Transformator ad terra
    01/27/2026
  • Impactus Praejudicialis Bias Directi Currentis in Transformeribus ad Stationibus Energiae Renovabilis Proximis Electrodis Terrae UHVDC
    Impactus DC Bias in Transformeribus ad Stationes Energeticae Renovabiles Proximas Electrodis Terrae UHVDCCum electrum terrae systematis transmissionis Ultra-Alta-Voltura Directa (UHVDC) sit prope stationem energeticae renovabilis, currus reditus per terram fluens potest causare incrementum potentialis terrae circa aream electri. Hoc incrementum potentialis terrae ducit ad mutationem potentialis puncti neutri transformatorum proximorum, inducendo bias DC (vel offset DC) in eorum nucleis. Talis bi
    01/15/2026
  • HECI GCB for Generators – Cepus SF₆ Circuit Breaker
    1. Definitio et Functio1.1 Munus Interruptoris Circuiti GeneratorisInterruptor Circuitus Generatoris (GCB) est punctum disiunctionis controllabile situatum inter generator et transformator incrementalis, servans ut interficium inter generator et rete electricitatis. Principales eius functiones includunt isolationem defectuum lateris generatoris et facilitationem controlis operationis durante synchronizatione generatoris et connectione ad rete. Principium operativum GCB non differt significanter
    01/06/2026
  • Apparatus Distributionis Transformatorisque Experimentatio Inspectio et Conservatio
    1. Manutentio et Inspectio Transformatoris Aperi interruptorem circuitus bassae tensionis (LV) transformatoris in manu, remove fusum alimenti controlis, et pende signum “Noli Claudere” super manubrium commutationis. Aperi interruptorem circuitus altae tensionis (HV) transformatoris in manu, claudi commutatorem terrae, exsolvare totaliter transformatorem, claude armarium interruptoris HV, et pende signum “Noli Claudere” super manubrium commutationis. Pro manutentione transformatoris sicci: primo
    12/25/2025
  • Quomodo Resistentiam Isolationis Transformatorum Distributionis Probes
    In operibus practicis, resistentia insulationis transformatorum distributionis saepe bis metitur: resistentiam inter spiram alti voltaginis (HV) et spiram bassi voltaginis (LV) plus vasum transformatoris, et resistentiam inter spiram LV et spiram HV plus vasum transformatoris.Si ambae mensurationes valores acceptabiles praebent, indicat quod insulatio inter spiram HV, spiram LV, et vasum transformatoris est probata. Si una mensuratio deficiat, testes pairwise resistentiae insulationis inter omne
    12/25/2025

Solutiones Relatae

  • Design Solution of 24kV Siccum Aera Insulatum Ring Main Unit
    Combinatio Solidi Insulationis Adiuvantis + Insulationis Aereae Siccae repraesentat directionem pro RMU 24kV. Per requirementa insulationis cum compactitate equilibrata et adiuvante solidum insulationis, testes insulationis sine magnificatione significativa dimensionum inter phasos et inter phasos et terram transigi possunt. Inclusio columnae pole solidificat insulationem pro interruptore vacuo et conductoribus eius coniunctis.Maintinendo spatium phasorum exiens 24kV ad 110mm, intensitas electri
    08/16/2025
  • Optimizatio Design Schematum pro Unitate Circulorum Principalium Aere Insulata 12kV ad Minuendam Probabilitatem Disruptionis Emissionis
    Cum celeri progressus industriae electricitatis, conceptus ecologicus de carbonis minore, energiae servanda, et conservatione ambientis profundissime integratus est in designum et fabricam productorum electricorum pro distributione et generatione electricitatis. Unitas Distributiva Circuli (RMU) est dispositivum electricum clavem in retibus distributionis. Securitas, conservatio ambientis, fides operativa, efficacia energetica, et oeconomia sunt tendentiae inevitabiles in eius progressu. RMUs tr
    08/16/2025
  • Analyse communium problematum in unitatibus principali circuitu isolatis gas 10kV (RMUs)
    Introductio:​​RMUs insulati gaseis 10kV sunt amplissime usitati propter multas suas utilitates, sicut quod sint perfecte clausi, habeant excellentem insulativam qualitatem, non requirant maintenance, sint compacti, et praebent installationem flexibilem et commodam. In hoc stadio, paulatim facti sunt nodus criticus in rete distributionis urbano anulari et iocabuntur partem significativam in systemate distributionis electricitatis. Difficultates in RMUs insulatis gaseis possunt graviter impingere
    08/16/2025
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum