Mga Pangunahing Katangian

Brand Switchgear parts
Numero ng Modelo Relay na may Tatlong Phase na Voltahan GRV8-03X hanggang 08X
Larawan na Pagsasahimpapawid 45Hz-65Hz
Serye GRV8

Mga Deskripsyon ng Produkto mula sa Supplier

Pagsasalarawan

Panggamit ng serye ng GRV8-03X hanggang 08X na mga produktong relay ng voltaheng panmonitor ng tatlong phase:
Ang serye ng GRV8-03X hanggang 08X ay malawakang ginagamit sa mga sumusunod na pangunahing sektor dahil sa kanyang mapagkakatiwalaang kakayahang mag-monitor at pampayakap na adaptabilidad:
1. Paggamit ng mobile devices at special vehicle power management:
Upang magbigay ng matatag na pagmomonitor ng tatlong-phase power para sa on-site engineering equipment, agricultural machinery (tulad ng harvester, tractor), refrigerated transport vehicles at iba pang mobile equipment, tiyaking ligtas at maasahan ang operasyon sa komplikado at nagbabago na kapaligiran ng suplay ng kuryente (tulad ng generator power supply o pansamantalang koneksyon ng kuryente), at iwasan ang pagkakansela o pagkasira ng equipment dahil sa hindi normal na voltaheng.
2. Proteksyon sa direksyon ng pag-rotate ng equipment:
Makatotohanang imomonitor ang sequence ng tatlong-phase power supply at mabilis na detekta ang mga error sa sequence (na maaaring sanhiin ang motor na umikot nang pabaliktad)
Ipadala ang mga control signal upang makapagbigay ng epektibong pagsasanggalang laban sa mechanical damage, production accidents, o safety incidents na dulot ng pabaliktad na operasyon ng mechanical equipment.
3. Automatic Switching System (ATS) para sa Primary at Backup Power Supply:
Sa mga lugar na nangangailangan ng mataas na reliable na suplay ng kuryente, tulad ng data centers, ospital, at critical production lines sa factories, ito ay ginagamit upang imomonitor ang estado ng normal (primary) power supply at emergency (backup) power supply (tulad ng generators). Kapag ang pangunahing suplay ng kuryente ay nabigo (tulad ng voltage loss, undervoltage, overvoltage, phase loss), ito ay maasahang magtrigger ng signal upang maneho ang switching device, seamless o maikling interupsiyon ng load upang lumipat sa backup power supply, tiyaking patuloy ang suplay ng kuryente.
4. Proteksyon ng motor at power load:
Real time monitoring ng tatlong-phase power supply para sa electric motors at iba pang mahahalagang power loads. Sa pagkakataon ng phase failure, ito ay agad na makakadetekta at ilalabas ang alarm o cut off control signal, epektibong maiiwasan ang sobrang init at pagkakasira ng motor dahil sa single-phase operation, at protektahan ang mahalagang equipment assets.
5. Proteksyon ng industrial production lines at mechanical equipment:
Malawakang ginagamit sa iba't ibang industriyal na automated production lines, pumps, fans, compressors at iba pang equipment, bilang isang front-end voltage protection unit, upang maiwasan ang pagkansela ng equipment, production interruption o pagkasira ng component dahil sa unstable grid voltage (overvoltage, undervoltage) o phase loss.

Mga tampok ng serye ng GRV8-03X hanggang 08X na mga produktong relay ng voltaheng panmonitor ng tatlong phase:
1. Mataas na presisyong true effective value measurement:
Sa pamamagitan ng paggamit ng teknolohiya ng true effective value measurement, maaari itong magbigay ng tumpak na resulta ng pagmeasure ng voltage (presisiyon ≤ 1%) kahit sa non-sinusoidal voltage conditions na may harmonics, tunay na naghahayag ng estado ng power grid.
2. Malawak na adaptabilidad ng voltage at flexibility ng wiring:
Nagbibigay ng 8 adjustable rated voltage levels na maaaring payakap sa standard grid voltages sa iba't ibang bansa at rehiyon sa buong mundo. Suportado ang parehong 3-phase 3-wire at 3-phase 4-wire (3L/3N) wiring methods upang tugunan ang iba't ibang on-site requirements.
3. Kamangha-manghang anti-interference performance:
Ang internal circuit ay dumaan sa professional anti-harmonic design optimization, at pinataasan para sa high interference industrial environments (tulad ng malapit sa frequency converters at high-power rectification equipment), epektibong nagsasanggalang laban sa harmonic interference at tiyaking ang stability at reliability ng pagmomonitor.
4. Intuitive status indication:
Na-equip ng high brightness LED indicator lights, malinaw na ipinapakita ang kasalukuyang working status ng relay (tulad ng power supply, faults, alarms, etc.), madali para sa on-site personnel na mabilis na kilalanin ang operating status ng sistema.
5. Ultra compact design:
Ginamit ang ultra-thin design na may lapad na lamang 18mm, malaki ang nakakatipid sa installation space sa loob ng control cabinet. Suportado ang standard 35mm DIN rail installation, madali at mabilis ang installation at disassembly, angkop para sa high-density wiring applications.

Technical parameters M460 M265
Function Monitoring 3-phase voltage
Monitoring terminals L1-L2-L3 L1-L2-L3-N
Supply terminals L1-L2 L1-N
Voltage range 220-230-240-380-400-415-440-460(P-P) 127-132-138-220-230-240-254-265(P-N)
Rated supply frequency 45Hz-65Hz
Measuring range 176V-552V 101V-318V
Threshold adjustment voltage 2%-20% of Unselected
Adjustment of asymmetry threshold 5%-15%
Hysteresis 2%
Phase failure value 70% of Un selected
Min=165V
70% of Un selected
Time delay Adjustable 0.1s-10s,10%
Measurement error ≤1%
Run up delay at power-up 0.5s time delay
Konb setting accuracy 10% of scale value
Supply indication green LED
Output indication red LED
Reset time 1000ms
Output 1×SPDT
Current rating 10A/AC1
Switching voltage 250VAC/24VDC
Min.breaking capacity DC 500mW
Temperature coefficient 0.05%/℃,at=20℃(0.05%℉,at=68℉)
Mechanical life 1×107
Electrical life(AC1) 1×105
Operating temperature -20°C to +55°C (-4 °F to 131 °F)
Storage temperature -35°C to +75°C (-22 °F to 158 °F)
Mounting/DIN rail Din rail EN/IEC 60715
Protection degree IP40 for front panel/IP20 terminals
Operating position any
Overvoltage category
Pollution degree 2
Max.cable size(mm2) solid wire max.1 x2.5or 2×1.5/with sleeve max.1 x2.5(AWG 12)
Tightening torque 0.8Nm
Dimensions 90x18x64mm
Weight 61g-66g
Alamin ang iyong supplier
Tindahan Online
Rate ng on-time delivery
Oras ng Pagsagot
100.0%
≤4h
Pangkalahatang Impormasyon ng Kompanya
Lugar ng Trabaho: 1000m² Kabuuang bilang ng mga empleyado: Pinakamataas na Taunang Export (US Dollar): 300000000
Lugar ng Trabaho: 1000m²
Kabuuang bilang ng mga empleyado:
Pinakamataas na Taunang Export (US Dollar): 300000000
Serbisyo
Uri ng Pagnenegosyo: Sales
Pangunahing Kategorya: Mga Aksesorya ng Pagsasakatawan/Pagsusuri ng mga aparato/Mataas na Voltaheng mga Aparato/Mga aparato sa mababang voltaje/Instrumentasyon/Mga Pagsasagawa ng Produksyon/Pangkalahatang Paggamit ng Enerhiya sa Pagproseso ng IEE-Business
Pamamahala ng Buhay
Mga serbisyo sa pangangalaga at pamamahala sa buong buhay para sa pagbili, paggamit, pagpapanatili, at售后 ng kagamitan, upang masiguro ang ligtas na operasyon ng mga kagamitang pangkuryente, tuluy-tuloy na kontrol, at maaliwalas na pagkonsumo ng kuryente.
Ang supplier ng kagamitan ay nakapasa sa sertipikasyon ng karapatang pumasok sa platform at teknikal na pagtatasa, tinitiyak ang pagtugon, propesyonalismo, at katiyakan mula pa sa pinagmulan.

Mga Produkto na May Kaugnayan

Kaalamayan na may Kaugnayan

  • Mga Aksidente sa Pangunahing Transformer at mga Isyu sa Pagsasanay ng Light Gas
    1. Tala ng Aksidente (Marso 19, 2019)Noong ika-16:13 ng Marso 19, 2019, inulat ng monitoring background ang isang light gas action ng No. 3 main transformer. Ayon sa Code for Operation of Power Transformers (DL/T572-2010), sinaunang tiningnan ng mga tauhan ng operation and maintenance (O&M) ang kondisyon ng No. 3 main transformer sa lugar.Konfirmasyon sa lugar: Inulat ng WBH non-electrical protection panel ng No. 3 main transformer ang isang Phase B light gas action ng katawan ng transformer
    02/05/2026
  • Mga Kamalian at Pamamaraan sa Paggamot ng Single-phase Grounding sa 10kV Distribution Lines
    Mga Katangian at mga Device na Paggamit sa Pagkakakilanlan ng Single-Phase Ground Fault1. Mga Katangian ng Single-Phase Ground FaultMga Signal ng Sentral na Alarm:Tumutunog ang bell ng babala, at nag-iilaw ang indicator lamp na may label na “Ground Fault sa [X] kV Bus Section [Y].” Sa mga sistema na may Petersen coil (arc suppression coil) na nakakonekta sa neutral point, nag-iilaw din ang indicator na “Petersen Coil Operated.”Mga Indikasyon ng Insulation Monitoring Voltmeter:Bumababa ang voltag
    01/30/2026
  • Pamamaraan ng pag-ground ng neutral point para sa 110kV~220kV power grid transformers
    Ang pagkakasunod-sunod ng mga paraan ng pag-ground ng neutral point sa mga transformer ng power grid na 110kV~220kV ay dapat tugunan ang mga pangangailangan ng insulation withstand ng mga neutral points ng mga transformer, at kailangang ito ring panatilihin ang zero-sequence impedance ng mga substation na hindi masyadong nagbabago, habang sinisigurado na ang zero-sequence comprehensive impedance sa anumang short-circuit point sa sistema ay hindi liliit ng tatlong beses ang positive-sequence comp
    01/29/2026
  • Bakit Gumagamit ng Bato Gravel Pebbles at Crushed Rock ang mga Substation?
    Bakit Gumagamit ng Bato, Gravel, Pebbles, at Crushed Rock ang mga Substation?Sa mga substation, ang mga kagamitan tulad ng power at distribution transformers, transmission lines, voltage transformers, current transformers, at disconnect switches ay nangangailangan ng pag-ground. Sa labas ng pag-ground, susuriin natin nang mas malalim kung bakit karaniwang ginagamit ang gravel at crushed stone sa mga substation. Bagama't tila ordinaryo lang sila, ang mga bato na ito ay gumaganap ng mahalagang pap
    01/29/2026
  • Bakit Kailangan I-ground ang Core ng Transformer sa Iisang Punto Lamang? Hindi ba Mas Handa ang Multi-Point Grounding?
    Bakit Kailangan I-ground ang Core ng Transformer?Sa panahon ng operasyon, ang core ng transformer, kasama ang mga metal na istraktura, bahagi, at komponente na naka-fix sa core at windings, ay lahat nasa malakas na elektrikong field. Sa impluwensya ng elektrikong field na ito, nakakakuha sila ng relatyibong mataas na potensyal sa paghahambing sa lupa. Kung hindi grounded ang core, magkakaroon ng potential difference sa pagitan ng core at ng mga grounded clamping istraktura at tank, na maaaring m
    01/29/2026
  • Pag-unawa sa Neutral Grounding ng Transformer
    I. Ano ang Neutral Point?Sa mga transformer at generator, ang neutral point ay isang tiyak na punto sa winding kung saan ang absolutong voltaje sa pagitan ng punto na ito at bawat panlabas na terminal ay pantay. Sa diagrama sa ibaba, ang puntoOay kumakatawan sa neutral point.II. Bakit Kailangan ng Pag-ground ang Neutral Point?Ang elektrikal na paraan ng koneksyon sa pagitan ng neutral point at lupa sa isang tatlong-phase AC power system ay tinatawag naneutral grounding method. Ang paraan ng pag-
    01/29/2026
Hindi pa rin nakakahanap ng tamang supplier Let verified suppliers find you Kumuha ng Kita Ngayon
Hindi pa rin nakakahanap ng tamang supplier Let verified suppliers find you
Kumuha ng Kita Ngayon
Inquiry
+86
I-click para i-upload ang file
I-download
Kumuha ng IEE-Business Application
Gamit ang app na IEE-Business upang makahanap ng kagamitan makuha ang mga solusyon makipag-ugnayan sa mga eksperto at sumama sa industriyal na pakikipagtulungan kahit kailan at saanman buong pagsuporta sa pag-unlad ng iyong mga proyekto at negosyo sa enerhiya