Relais Tension Triphasée GRV8-03X ad 08X

  • 3 Phase Voltage Relay GRV8-03X to 08X
  • 3 Phase Voltage Relay GRV8-03X to 08X
  • 3 Phase Voltage Relay GRV8-03X to 08X
  • 3 Phase Voltage Relay GRV8-03X to 08X
  • 3 Phase Voltage Relay GRV8-03X to 08X

Attributa principalia

Marca Switchgear parts
Numerus Modeli Relais Tension Triphasée GRV8-03X ad 08X
Frequenta nominata 45Hz-65Hz
Series GRV8

Descriptiones productorum a fornitori

Descriptio

Applicatio GRV8-03X ad 08X series trium phaseorum monitorensis relictuum productorum:
Series GRV8-03X ad 08X propter suam fidelem praestantiam in monitorendo et flexibilem adaptabilitatem late utitur in sequentibus clavibus regionibus:
1. Administratio potestatis mobilium dispositivorum et specialium vehiculorum:
Ad praebendum stabilis trium phaseorum potestatis monitorendae pro instrumentis ingeniariis in loco, machinis agricolis (sicut messores, tractors), vehiculis refrigerantis transportis aliisque mobilibus dispositivis, quae securum et fidum operari possint in complexis et variabilibus potestatis suppleendi ambientibus (sicut generatores vel temporaria accessio potestatis), et praeveniunt cessationem vel damnum instrumentorum ex anormali tensione.
2. Protectio rotationis directionis instrumentorum:
Accurate monere sequentiam trium phaseorum potestatis et cito detegere errores sequentiae (qui fortasse motorem in contrariam partem movere faciant)
Signa controlis mittere ad efficaciter prohibendum mechanicum damnum, accidentia productionis, vel incidentia securitatis ex inversa operatione instrumentorum mechanicorum.
3. Systema Automaticum Commutandi (ATS) pro primario et secundario suppeditamento potestatis:
In locis quibus requiritur summa fidelitas suppeditandi potestatis, sicut data centra, hospitalia, et critica lineae productionis in fabris, utitur ad monendum statum normalis (primarii) suppeditamenti potestatis et emergentis (secundarii) suppeditamenti potestatis (sicut generatorum). Quando principale suppeditamentum defecit (sicut amissio tensionis, subtensionis, supertensionis, aut amissio phaseos), potest fideliter signum provocare ad agendum commutationem dispositivi, sine intermissione vel brevi intermissione oneris ad transmutandum ad secundarium suppeditamentum, securans continuitatem potestatis.
4. Protectio motorum et onerum potestatis:
Monere tempore realem trium phaseorum potestatis pro motoribus electricis et aliis importantibus oneribus potestatis. Si contingat defectus phasei, potest confestim detegere et signum allarmi emitti vel signum controlis disjungendi, efficaciter prohibens motor a supercaldendo et comburendo propter singularem operationem, et protegens pretiosos instrumentales assets.
5. Protectio industrialium lineae productionis et instrumentorum mechanicorum:
Late utitur in diversis automatizatis lineis productionis, pompis, ventilatoribus, compressoribus aliisque instrumentis, ut unitas frontalis protectionis tensionis, ad prohibendum cessationem instrumentorum, interruptionem productionis, vel damnum componentium ex instabili reticulo tensionis (supertensionis, subtensionis) aut amissione phasei.

Characteristica productorum series GRV8-03X ad 08X trium phaseorum monitorensis relictuum:
1. Precisio altior vera mensura valoris effective:
Per usum veri mensurae valoris effectivi, accurate dat resultatum mensurae tensionis (accurate ≤ 1%) etiam sub non sinusoidali conditione tensionis contenta harmonics, vere reflectens statum reticuli potestatis.
2. Lata adaptabilitas tensionis et flexibilitas connectionis:
Praebet octo regulabiles gradus tensionis nominatae quae possunt adaptari ad standardes tensiones reticuli in diversis terris et regionibus orbis. Simul supportat modos connectionis trium phaseorum tria filia et trium phaseorum quattuor filia (3L/3N) ad satisfaciendum diversis locis requisitis.
3. Excellentis resistentia ad perturbationem:
Circuitus internus subiit optimisationem professionalis contra harmonicos et est roboratus pro altis perturbationibus industrialibus (sicut iuxta converteres frequentiae et magna rectificativa dispositiva), efficaciter suppressit perturbationem harmonicam et securat stabilitatem et fiduciam monitorendi.
4. Indicatio intuitiva status:
Equipatur cum luminibus indicativis LED altae luminositatis, quae clare ostendunt actum statum relictui (sicut supplimentum potestatis, vitia, allarmi, etc.), faciens facile personis in loco cito identificare statum systematis operantis.
5. Design ultra compactus:
Adoptans design ultra tenuis latitudine tantum 18mm, magnopere servat spatium installationis intra armariolum controlis. Supportat installationem standard 35mm DIN rail, cum facilis et celeris installatione et disjunctione, apta pro applicationibus densa connexiones.

Parametri technici M460 M265
Functio Monere trium phaseorum tensionis
Terminalia monendi L1-L2-L3 L1-L2-L3-N
Terminalia suppeditandi L1-L2 L1-N
Ambitus tensionis 220-230-240-380-400-415-440-460(P-P) 127-132-138-220-230-240-254-265(P-N)
Frequensia nominata suppeditamenti 45Hz-65Hz
Ambitus mensurae 176V-552V 101V-318V
Tensio adjustmentis liminis 2%-20% Unselecti
Adjustment liminis asymmetriae 5%-15%
Hysteresis 2%
Valorem defectus phasei 70% Un selecti
Min=165V
70% Un selecti
Dilatio temporis Regulabilis 0.1s-10s,10%
Error mensurae ≤1%
Dilatio accensionis initii 0.5s dilatio temporis
Accuracy setting Konb 10% valoris scalae
Indicatio suppeditamenti LED viridis
Indicatio output LED rubrum
Tempus reset 1000ms
Output 1×SPDT
Rangus currentis 10A/AC1
Tensio commutationis 250VAC/24VDC
Capacitas minima commutationis DC 500mW
Coefficiens temperaturae 0.05%/℃,at=20℃(0.05%℉,at=68℉)
Vita mechanica 1×107
Vita electrica(AC1) 1×105
Temperatura operativa -20°C ad +55°C (-4 °F ad 131 °F)
Temperatura conservandi -35°C ad +75°C (-22 °F ad 158 °F)
Installatio/DIN rail Din rail EN/IEC 60715
Gradus protectionis IP40 pro fronte panelis/IP20 terminalibus
Positio operativa quaelibet
Categoria supertensionis
Gradus pollutionis 2
Max.cable size(mm2) solid wire max.1 x2.5or 2×1.5/with sleeve max.1 x2.5(AWG 12)
Torque compaginis 0.8Nm
Dimensiones 90x18x64mm
Pondus 61g-66g
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Venditio
Categorias Principales: pars componentium/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum