• 27kV 15.5kV outdoor vacuum Single-phase recloser
27kV 15.5kV outdoor vacuum Single-phase recloser
discuss personally
Model
RWDRC
Basic info
Brand ROCKWILL
Model NO. 27kV 15.5kV outdoor vacuum Single-phase recloser
Rated frequency 50/60Hz
Rated line charging current 10A
IP grade IP66
Series RWDRC
Product Detail

Description :

The RWDRC series of single-phase reclosers are designed in accordance with IEC 62291-111-2019 (IEEE C37.60-2018). They are distribution network solution products that integrate multiple technologies such as current protection, communication, and self-power supply from line current.In terms of fault positioning, the device uses a variety of advanced technical means, such as traveling wave ranging and impedance method.

When a cable fault occurs, these technologies can quickly and accurately determine the location of the fault point with a very small margin of error. This greatly shortens the time for fault troubleshooting and repair, reducing the power - outage time and its impact on users.

This product is suitable for the protection of branch lines of overhead lines in the distribution network or the protection of user boundaries. When a permanent fault occurs on the line, it can quickly cut off the fault to prevent the fault from spreading to the main line. When a temporary fault occurs on the line, the line power supply can be restored through multiple reclosing operations, reducing the power outage time and improving the reliability of power supply.

Main function introduction:

  • Fault Detection and Isolation

  • Reclosing Function

  • Multiple Reclosing Control

  • Protection Coordination Function

Technology parameters:

image.png

Vacuum arc-extinguishing chamber parameters

image.png

Magnetic force actuator parameters

image.png

Current sensor parameters

image.png

Structure diagram

image.png

image.png

Device structure:

image.png

image.png

Installation schematic diagram

image.png

image.png

Q:What is a recloser used for?

A:A recloser is an electrical device used in power distribution systems. It is primarily used to automatically reconnect an electrical circuit after a fault has been detected and cleared. This helps to minimize power outages and improve the reliability of the power supply by quickly restoring electricity to the affected area.

Q: What is the difference between a breaker and a recloser?

A:A breaker is a device that can open and close a circuit under normal and fault conditions to protect the system from overloads and short - circuits. A recloser, however, is designed to automatically close the circuit a few times after a fault, in the hope that the fault was temporary, reducing outage time.

Q:What is a single-phase appliance?

A: A single - phase appliance is an electrical device that operates on a single - phase power supply. It uses the alternating current provided by a single - phase circuit, which has one active wire and one neutral wire. Common examples include most household appliances like refrigerators, televisions, and microwaves, which are designed to work with the standard single - phase power in homes.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!