• 252kV HV gas-insulated metal-enclosed switchgear(GIS)
252kV HV gas-insulated metal-enclosed switchgear(GIS)
$1200.00
Model
ZF29-252
Basic info
Brand Wone
Model NO. 252kV HV gas-insulated metal-enclosed switchgear(GIS)
Rated voltage 252kV
Rated normal current 4000A
Rated frequency 50(Hz)
Series ZF29-252
Product Detail

Description:

ZF29-252 gas-insulated metal-enclosed switchgear (referred to as GIS) is used for three-phase AC 50HZ, 220KV power system. The product adopts a common-phase three-station isolated grounding switch structure and modular design, which can meet various wiring methods.

Industry applications:

It is mainly used in power plants, substations, and large industrial and mining enterprises. Divide and combine no-load, load and fault currents, conversion loads, isolation lines, grounding protection and measurement of power transmission and transformation systems.

Features:

  • The circuit breaker adopts horizontal arrangement, the arc extinguishing chamber adopts a single-break double-acting structure, and the self-energy arc extinguishing principle is equipped with a low-power spring operating mechanism, which effectively reduces mechanical stress, has high mechanical operation reliability, and has a mechanical life of 10,000 times.

  •   Adopt three-station isolation grounding switch structure, mechanical interlocking between isolation and grounding, effectively avoid misoperation, high reliability, and mechanical life of 10,000 times.

  •   Three-station isolation grounding switch and main bus adopt three-phase co-box structure. The sealing surface and bonding surface of SF6 gas are reduced, which greatly reduces the air leakage rate; The three-station isolated grounding switch has no complex external connecting rods and connectors, simple structure and excellent corrosion resistance.

  • The rated SF6 gas pressure is low, except for the circuit breaker, the other gas chambers are rated at 0.4MPa, which greatly reduces the use of SF6 gas and reduces the greenhouse effect.

Technical parameters:

image.png

image.png

Dimension:

企业微信截图_17160150106667.png


Product show:

SloFyeCBRhu6SBvSmY_jNw.jpg_500xaf.jpg


Why choose us:

  • We have a professional service team.

  • We have good after-sales.

  • We can guarantee the quality of our products.

What is the insulation principle of gas-insulated switches?

Insulation Principle:

  • In an electric field, the electrons in SF₆ gas molecules are slightly displaced from the nuclei. However, due to the stability of the SF₆ molecular structure, it is difficult for electrons to escape and form free electrons, resulting in high insulation resistance. In GIS (Gas-Insulated Switchgear) equipment, the insulation is achieved by precisely controlling the pressure, purity, and electric field distribution of the SF₆ gas. This ensures a uniform and stable insulating electric field between the high-voltage conductive parts and the grounded enclosure, as well as between different phase conductors.

  • Under normal operating voltage, the few free electrons in the gas gain energy from the electric field, but this energy is not sufficient to cause collision ionization of the gas molecules. This ensures the maintenance of the insulating properties.



Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
What are the common faults of low-voltage voltage transformers?
What are the common faults of low-voltage voltage transformers?
1. Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In lo
Oliver Watts
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!