• 2500kVA 11kV Oil-immersed distribution transformer three-phase
  • 2500kVA 11kV Oil-immersed distribution transformer three-phase
  • 2500kVA 11kV Oil-immersed distribution transformer three-phase
2500kVA 11kV Oil-immersed distribution transformer three-phase
discuss personally
Model
S-11KV-2500KVA
Basic info
Brand Vziman
Model NO. 2500KVA 11KV Oil-immersed distribution transformer three-phase
Rated voltage 11kV
Rated capacity 2500kVA
Series S
Product Detail

Description:

Oil immersed transformer ,use our company special calculation and validation procedures to make sure theperformance of products. superior process equipment ,elaborate materialselecting and efficient manufacturing make the transformer have smallvolume,light weight,low loss,low partial discharge,low noise characteristics.

The product is stable,reliable,economic, environmental protection. lt can beapplied to many places such as power plants,transformer substation ,largeindustrial mining and petrochemical enterprise and so on.

Features:

  • Ultralow no-load loss

  • Energy saving and great power consuming efficiency

  • Copper coil winding, strong short circuit resistance ability

  • Dyn11 coil connection decrease the influences of harmonic wave

  • Fully sealed structure for maintenance free

  • Slow insulation aging & longer serving life

Parameters:

Oil-immersed distribution transformer three-phase

Model NO.

S-2500-11

Product classification

Distribution transformer

Rated capacity

2500kVA

Primary voltage

11kV

Secondary voltage

0.4kV

Number of phase

3

Number of winding

2

Rated frequency

50Hz

Tap changer

OCTC

Tap range

±2×2.5%

Vector group

Yd11400v delta 11kv star 

Cooling system

ONAN

No-load loss

3800+10%

Load loss

19000+10%

Standard

IEC60076

Impedance

4.75±10%

Basic insulation level

75/28kv

Winding material ( H.V & L.V)

Copper

The way the bushing appears

Porcelain

Power frequency withstand voltage

——

Lightning impulse

——

The temperature rise—Winding

——

The temperature rise --Top oil

——

Tank color

——

Creepage distance

——

Environmental requirement

——

Transformer structure

Sealed

External dimensions:

企业微信截图_17240297972200.png

Size

2425mm×1520mm×2170mm

Weight

3080KG


Environmental requirement:

Max. ambient temperature


Altitude


Product show:      

   

Yawei 160kVA 10kv Hot Selling Oil-Filled Three-Phase Distribution Transformer with UL

What are the structural characteristics of oil-immersed distribution transformers?

Definitions and Characteristics:

  • Oil-Immersed: It means that the iron core and windings of the transformer are immersed in insulating oil, and the oil plays a dual role of cooling and insulation.

  • Distribution Transformer: It is used to convert high-voltage electrical energy into low-voltage electrical energy for users' use.
    Three-Phase: Usually, it means that the transformer has three independent windings and is applicable to three-phase alternating current systems.

Structural Characteristics:

  • Iron Core: It is usually made by laminating high-quality silicon steel sheets, featuring low loss and low noise.

  • Windings: The primary winding and the secondary winding are usually wound with copper wires, possessing excellent electrical conductivity and mechanical strength.

  • Insulating Oil: The inside of the transformer is filled with insulating oil. The oil not only plays a cooling role but also provides good insulation performance.

  • Oil Tank: The iron core and windings of the transformer are installed in the oil tank. The oil tank is usually made of steel plates and has good sealing performance.

  • Cooling System: Depending on the power level, oil-immersed transformers can adopt natural cooling, air cooling or forced oil circulation cooling methods.

  • Bushing: The high-voltage and low-voltage leads are led out through the bushing. The bushing has good insulation performance to ensure safe operation.


Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!