Key attributes

Brand ROCKWILL
Model NO. 20kV 44kV 145kV 150kV Three Phase Oil-Immersed Neutral Earthing Transformer Custom Factory
Rated voltage 20kV
Rated capacity 100kVA
Phases Three-phase
Series JDS

Product descriptions from the supplier

Description

Product Overview

As a pioneer and the first professional original manufacturer in China's earthing transformer industry, decades of dedicated focus have enabled us to accumulate strong technical strength and even establish the fundamental standards for industry development. Covering the entire chain from breakthroughs in core technological innovation to large-scale production and delivery, we have built an independent ecological system. With leading and stable product performance as well as extremely reliable quality, we have become a trusted choice in the field of power grid construction.

This series of three-phase oil-immersed neutral earthing transformers is a customized core equipment specifically designed for medium- and high-voltage power systems, covering voltage classes from 20kV to 150kV and adopting a fully sealed oil-immersed structure. Through factory-customized production, the product can be flexibly configured according to the user's grid parameters, installation environment, and protection requirements, providing a reliable artificial neutral point solution for ungrounded or low-current grounded systems. It effectively suppresses arc grounding overvoltage and enhances grid operational stability and safety.

Basic Info

Some of these earthing transformers cover voltage levels including:3.3kV / 6kV / 11kV / 15kV / 20kV / 22kV / 30kV / 33kV / 34.5kV / 36kV / 44kV / 66kV / 88kV / 110kV / 132kV / 145kV / 150kV / 220kV / 275kV / 330kV / 400kV, etc. The current withstand time ranges from 1s, 2s, 3s, 5s, 6s, 8s, 9s, 10s, 30s, 60s, 1hour to 2hours, and customization is available.

Model NO.

JDS

Core

Core-type Transformer

Cooling Method

Oil-immersed Type Transformer

Winding Type

Two-winding Transformer

Certification

ISO9001

Usage

Power Transformer

Frequency Characteristics

Power Frequency

Shape of Core

Ring

Brand

Rockwill

Transformer

Earthing Transformer

Rated Capacity

100 kVA

Color

Grey or Customized

Coil Material

Copper

Losses

Low Losses

Transformer Phase

3 Phase

Iron Core

Power Transformer Core

Transport Package

Wooden Case

Specification

CTQC type tested

Trademark

Rockwill

Origin

Zhejiang, China

HS Code

85042100

Production Capacity

5000MAV/Year

Key Specifications

  • Model: JDS-100/20

  • Capacity: 100kVA

  • Voltage: 20kV

  • Frequency: 50/60Hz

  • Winding: Copper two-winding design

  • Core: Ring-shaped silicon steel

  • Cooling: ONAN (Oil Natural Air Natural)

  • Impedance: Low zero-sequence impedance (<10&Omega;)

  • Certification: ISO 9001, CTQC tested

Technical Advantages

     Superior Grounding Performance

    • Specially designed winding configuration for optimal neutral point stability

    • Withstands 100A short-circuit current for 10 seconds

    • Low zero-sequence impedance ensures effective fault current diversion

    Advanced Oil-Cooled Design

    • Hermetically sealed corrugated tank prevents oil contamination

    • Mineral oil insulation with -30&deg;C to +40&deg;C operating range

    • Optional Midel 7131 ester fluid for enhanced fire safety

    Robust Construction

    • Heavy-gauge steel tank with anti-corrosion treatment

    • Precision-engineered core with reduced magnetic losses

    • Vibration-resistant mounting system

    Smart Protection Features

    • Standard Buchholz relay for internal fault detection

    • Pressure relief device for overload conditions

    • Oil level indicator with alarm contacts

Application Scenarios

Industrial Power Systems

    • Ideal for manufacturing plants with sensitive equipment

    • Protects against ground faults in 20kV distribution networks

    • Suitable for harsh industrial environments

    Renewable Energy Installations

    • Wind farm collector substations

    • Solar park step-up stations

    • Biomass power generation facilities

    Infrastructure Projects

    • Metro power supply systems

    • Airport electrical networks

    • Hospital backup power systems

Why Choose Rockwill?

  • 20+ years of transformer manufacturing expertise

  • Custom engineering support available

  • Complete type test reports provided

  • Global service network with 24/7 technical support

  • Environmentally conscious production processes

FAQ
Q: What is the function of the auxiliary winding of an earthing/grounding transformer, and what are its common specifications?
A:

The auxiliary winding is an optional configuration of the earthing/grounding transformer. Its core function is to "provide low-voltage power for local loads in the substation", avoiding the additional configuration of a dedicated distribution transformer and reducing system cost. Its design follows the principle of "small capacity and standardization". Common specifications are: the voltage level can be 400V/230V (adapting to domestic and European standards) or 480V/277V (adapting to North American standards), and the capacity is usually no more than 200kVA, which can meet the power demand of auxiliary equipment such as control circuits, lighting and ventilation in the substation. It should be noted that the auxiliary winding only serves as an "auxiliary function" and does not affect the core grounding performance of the earthing/grounding transformer.

Q: What are the core international standards governing the design, production and testing of earthing/grounding transformers, and what are their respective focuses?
A:

<meta />

At present, the mainstream global standards are divided into the IEEE system and the IEC system. Domestic standards mostly refer to IEC and are customized according to national conditions. The core standards and their respective focuses are as follows:
  • IEEE 32: The dominant standard in North America, focusing on the "fault performance" of earthing/grounding transformers. It details the core requirements such as zero-sequence impedance test methods, short-time withstand current calculation, and mechanical strength verification, and is a key basis for the selection of high-voltage and extra-high voltage systems.
  • IEC 60076 series: The core international general standard. Among them, IEC 60076-8 specifically regulates the winding design, impedance requirements and test methods of earthing/grounding transformers; IEC 60076-1 defines the general requirements for insulation media; IEC 60076-2 specifies the classification and performance indicators of cooling methods; IEC 60076-5 specifies the test specifications for short-time withstand capacity, forming a complete technical system.
  • ANSI C57.12/IEC 60038: ANSI C57.12 supplements the manufacturing process requirements of earthing/grounding transformers in North America; IEC 60038 unifies the nominal values of voltage levels to ensure the compatibility of products from different countries.
  • Domestic relevant standards: Such as GB/T 6451, which refers to the IEC 60076 series and puts forward supplementary requirements on efficiency, temperature rise and harmonic resistance according to the characteristics of China's power grid.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

Related Solutions

Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.