• 1KVL.V heat shrinkable termination kit
  • 1KVL.V heat shrinkable termination kit
  • 1KVL.V heat shrinkable termination kit
  • 1KVL.V heat shrinkable termination kit
  • 1KVL.V heat shrinkable termination kit
1KVL.V heat shrinkable termination kit
discuss personally
Model
JSY-1kV/5
JSY-1kV/4
JSY-1kV/3
JSY-1kV/2
JSY-1kV/1
Basic info
Brand Switchgear parts
Model NO. 1KVL.V heat shrinkable termination kit
Rated voltage 1kV
number of core 5-core
Series JSY
Product Detail

Use and characteristics

1kV Heat shrinkable cable accessories products widely used 0.6 / 1KV cross-linked cable terminal and the middle of the continuous insulation treatment, according to the number of cable core can be divided into 1-core. 2-cores. 3-cores.4-cores. 5-cores and other cables to meet the different cross-section. With small size. Light weight. Reliable operation. Easy installation and so on.

Applicable cable cross section

Applicable cable core number

NO

Section(mm2)

1-core

2-cores

3-cores

4-cores

5-cores

1

10~16

JSY-1/1.0

JSY-1/2.0

JSY-1/3.0

JSY-1/4.0

JSY-1/5.0

2

25~50

JSY-1/1.1

JSY-1/2.1

JSY-1/3.1

JSY-1/4.1

JSY-1/5.1

3

70~120

JSY-1/1.2

JSY-1/2.2

JSY-1/3.2

JSY-1/4.2

JSY-1/5.2

4

150~240

JSY-1/1.3

JSY-1/2.3

JSY-1/3.3

JSY-1/4.3

JSY-1/5.3

5

300~500

JSY-1/1.4

JSY-1/2.4

JSY-1/3.4

JSY-1/4.4

JSY-1/5.4

Know your supplier
Switchgear parts
VoltEdge Solutions​​ specializes in manufacturing premium ​​MV switchgear accessories​​ for global power distribution systems. Our product range includes circuit breaker modules, disconnector spares, and surge arrestors, engineered for ​​24kV+ substations​​ and renewable energy plants. With ISO-certified production and 24/7 technical support, we ensure ​​reliability, compliance​​ with IEC standards, and rapid global supply.
Main Categories
Electrical fittings/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
Detection, Testing and Comprehensive Monitoring of PV Grid-Connected Cabinets
Detection, Testing and Comprehensive Monitoring of PV Grid-Connected Cabinets
Photovoltaic (PV) Grid-Connection CabinetA photovoltaic (PV) grid-connection cabinet, also known as a PV grid-connection box or PV AC interface cabinet, is an electrical device used in solar photovoltaic power generation systems. It is primarily responsible for converting the direct current (DC) electricity generated by a PV system into alternating current (AC) and connecting it to the utility grid.Main Components of a PV Grid-Connection Cabinet:DC Input Terminals: Receive DC power generated by
Garca
08/28/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!