• 180kW DC EV charger
  • 180kW DC EV charger
180kW DC EV charger
discuss personally
Model
WZ-180kW-1E
Basic info
Brand RW Energy
Model NO. 180kW DC/DC EV charger
Rated Output Rating 180kW
Output Voltage DC150-750V
Connector Options CCS2
Cable Length 5m
Input Voltage DC260-900V
Series DC EV Chargers
Product Detail

Description:
Designed for high-efficiency EV charging, this 180kW DC fast charger employs advanced DC/DC conversion technology and supports mainstream standards like CCS, CHAdeMO, and GBT,  Integrated with intelligent temperature control and power management systems, it maintains stable output in extreme environments from -30°C to 55°C, making it ideal for high-frequency charging scenarios such as commercial parking lots, highway rest areas, and logistics parks.

Key Features:

Ultra-Fast Charging Performance

  • Charges vehicles from 10% to 80% in just 30 minutes at 180kW, suitable for passenger cars and light commercial vehicles.

  • Liquid-cooled thermal management ensures temperature differentials within ±3°C, enabling continuous high-power operation.

Universal Compatibility

  • Seamlessly switches between CCS1/CCS2, CHAdeMO, and GBT protocols, eliminating the need for adapters.

  • Directly compatible with Tesla, BYD, NIO, Volkswagen, and 95%+ global EV models.

Intelligent Management System

  • Built-in BMS communication interface optimizes charging curves based on real-time battery status, extending battery life.

  • Supports OTA updates and integrates with third-party platforms for data analytics, remote monitoring, and predictive maintenance.

Comprehensive Safety

  • Equipped with overvoltage/overcurrent protection, leakage detection, lightning protection, and IP54-rated enclosure for outdoor durability.

  • Ergonomic charging gun with PEL (Protection against Electric Shock) and mechanical locking mechanism.

Flexible Deployment

  • Floor-standing or wall-mounted installation options with a compact 0.5㎡ footprint.

  • Grid-friendly design compliant with IEC 61000-3-2, minimizing harmonic interference.

Parameters:

Name

DC/DC180kW-CCS1

Size(mm)

750mm X 600mm X 1290mm

Weight(KG)

250KGs

Screen Material

7’LCD

Shell Material

Sheet Metal

DC Input

Voltage

260VDC-900VDC

Current

≤200A

DC Output

Voltage

150VDC~750VDC

Voltage stabilization accuracy

<±0.5%

Current stabilization accuracy

≤±1%(Output load 20%~100% Rated range)

Voltage ripple factor

≤1%(150~750V, 0~20MHz)

Efficiency

≥ 95%, @750V, 50%~100% load current, rated 710V input

IP Degree of protection

IP54

Operating ambient temperature

-40℃~70℃, Above 50℃, use with derating

Relative humidity

≤95%RH, no condensation

Altitude

≤2000 meters,Derating for use above 2000 meters

Cooling mode

Forced air cooling

Remote monitoring mode

Ethernet / 4G/Wi-Fi

Startup mode

RFID/APP

Standby power

180W

Charging standard

IEC-62196-2;EN61851;ISO 15118

Installation method

Floor mounted

Metering accuracy

0.5

Safety protection function

Input Overvoltage Protection

≥900VDC

Input undervoltage protection

≤260VDC

Output overvoltage protection

DC150V ~ 750V can be set

Over temperature protection

Derating above 55 ℃; 75 ℃ protection shutdown

Short circuit protection

Yes

Emergency stop protection

Yes

Lightning protection

Level 2 lightning protection standard

How does a DC EV charging pile convert electricity?

The DC Fast Charger is a device specifically designed for rapidly charging electric vehicles. The DC charging pile initially obtains alternating current (AC) from the power grid, typically at a voltage of single-phase 230V or three-phase 400V, depending on the regional standards. Inside the charging pile, there are power electronic devices that are responsible for converting the AC from the grid into direct current (DC) suitable for use by the electric vehicle's battery.



Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High voltage/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!