• 30 KVA - 1000 KVA Pad Mounted Transformer with Layer Coil
30 KVA - 1000 KVA Pad Mounted Transformer with Layer Coil
discuss personally
Model
ZGS-30/1000 KVA 
Basic info
Brand POWERTECH
Model NO. 30 KVA - 1000 KVA Pad Mounted Transformer with Layer Coil
Rated capacity 1000kVA
Series ZGS
Product Detail

Description

This product features a fully insulated design, ensuring operational safety and reliability. With high overload capacity, it effectively mitigates sudden short-circuit risks. The durable outer shell provides exceptional impact resistance and robust mechanical performance, enhancing overall durability. Designed for long-term use, this transformer delivers reliable electrical and mechanical performance in various applications.

Feature

Diverse Types: Supports both loop feed and radial feed configurations.

Wide Capacity Range: Rated capacity from 30 KVA to 1000 KVA, meeting various needs.

Flexible Voltage Options: Supports multiple primary & secondary voltages.

Efficient Cooling: Onan cooling method, suitable for outdoor installation.

Copper Coil: Excellent conductivity, low loss, and long lifespan.

Standardized Production: ISO9001 certified, ensuring reliable quality.

Robust Packaging: Plywood box protection for safe transportation.

Parameter

Structure diagram

Know your supplier
POWERTECH
We are an electrical company that manufactures and sells high and low voltage electrical products.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$120000000
Professional Experience
7 years
Workplace
580000m²
占位
占位
Related Products
Related Knowledges
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?Electricity travels long distances before reaching consumers. Power plants, often remote, supply electricity through hundreds of miles and multiple substations. High-voltage transmission reduces line losses, with both AC and DC used. Though AC is familiar via utility poles and home outlets, HVDC offers unique advantages in power transmission.The goal of power transmission is to minimize losses and costs. While both face influencing factors, HVDC has more
Edwiin
07/19/2025
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Neutral - Point Grounding Modes and Protection of Transformers in Power GridsFor systems ranging from 110 kV to 500 kV, an effective grounding method shall be adopted. Specifically, under all operating conditions, the ratio of zero - sequence reactance to positive - sequence reactance X0/X1 of the system should be a positive value and not exceed 3. Meanwhile, the ratio of zero - sequence resistance to positive - sequence reactance R0/X1should also be a positive value and not exceed 1.In 330 kV a
Leon
07/19/2025
What are the differences between an alternating current generator and a direct current generator?
What are the differences between an alternating current generator and a direct current generator?
Main Differences Between AC and DC GeneratorsAn electrical machine is a device that converts mechanical energy into electrical energy and vice versa. A generator is a type of such machine that converts mechanical energy into electrical energy. However, the electrical energy generated can be in either alternating current (AC) or direct current (DC) form. Thus, the primary difference between AC and DC generators is that they generate alternating current and direct current respectively. While there
Edwiin
07/18/2025
What is an electricity meter?
What is an electricity meter?
Definition: An energy meter is a device used to measure the electrical energy consumed by an electrical load. Electrical energy refers to the total power consumed and utilized by a load over a specific period of time. Energy meters are used in domestic and industrial AC circuits to measure power consumption. They are relatively inexpensive and accurate.Construction of an Energy MeterThe construction of a single - phase energy meter is shown in the figure below.The energy meter consists of four m
Edwiin
07/18/2025
Analysis of the Principle of Second - harmonic Restraint for Overcurrent Protection of Distribution Automation Switches
Analysis of the Principle of Second - harmonic Restraint for Overcurrent Protection of Distribution Automation Switches
Substance of Second - harmonic Restraint in Overcurrent ProtectionThe substance of second - harmonic restraint in overcurrent protection is to use the second - harmonic component to judge whether the current is a fault current or an excitation inrush current. When the percentage of the second - harmonic component to the fundamental - wave component is greater than a certain value, it is judged to be caused by the excitation inrush current, and the overcurrent protection is blocked.Therefore, the
Leon
07/18/2025
What are the common faults of low-voltage voltage transformers?
What are the common faults of low-voltage voltage transformers?
Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In low
Felix Spark
07/18/2025
×
Inquiry
Download