• 12kV/24kV/36kV/40.5Kv Compact Substation
12kV/24kV/36kV/40.5Kv Compact Substation
discuss personally
Model
YBM-40.5/630
Basic info
Brand ROCKWILL
Model NO. 3.12kV /24kV/36kV/40.5Kv Compact Substation
Rated voltage 40.5kV
Rated normal current 630A
Rated frequency 50/60Hz
Series YBM
Product Detail

Descripton

The YBM series products represent a highly integrated power distribution solution, meticulously assembling medium-voltage (MV) switchgear, transformers, and low-voltage (LV) distribution equipment based on fixed connection schemes. Engineered for versatility, this series of substations is ideally suited for diverse applications, including neighborhood utility units, hotels, large-scale construction sites, and high-rise buildings. It operates efficiently within voltage ranges of 12kV, 24kV, 36kV, and 40.5kV, at a frequency of 50Hz, and can handle capacities of up to 2500kVA.

Adhering to stringent international standards, the YBW series complies with IEC60076 and IEC1330, as well as the ANSI/IEEE standards C57.12.00, C57.12.20, and C57.12.90. Additionally, it meets the requirements of BS171 and SABS 780, ensuring reliable performance and quality assurance across various regions and industries.

Structure Characteristics

  • Our box type transformer substations come in two distinct configurations: corridor - style and non - corridor - style. The frames are constructed from high - quality anti - corrosive steel through welding, while the bases are made of hot - galvanized steel.

  • Each box - type transformer substation consists of three compartments: the high - voltage (HV) cabinet, the low - voltage (LV) cabinet, and the transformer cabinet. The internal layout can be tailored to specific customer needs. The double - layer roof design features an air - filled cavity, which provides effective insulation against temperature increases.

  • These substations rely on natural air cooling as the standard option. However, forced air cooling and automatic anti - condensation equipment can be added as optional enhancements. To safeguard the transformer, various combinations of load switches and fuses are available.

  • They support multiple power supply modes, including terminal power supply, ring power supply, and dual power supply. The LV cabinets have a welded structure and are equipped with screen - type nameplates. Additionally, the cabinets are firmly fastened to the tank for stability.

Main Technical Specifications

Service Condition

  • Both indoor or outdoor

  • Air temperature: 

  • Maximum temperature: +40℃; Minimum temperature:-25℃

  • Humidity: Monthly average humidity 95%; Daily average humidity 90% .

  • Altitude above sea level: Maximum installation altitude: 2000m.

  • Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.

  • No frequent violent shake

Note: Beyond those services condition should enquiry to manufacturer technical dept during order

Note: The above parameter is only subject to our standard design, special requirement can be customized


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!