• ZHW Series HV Gas insulation switchgear (GIS)
  • ZHW Series HV Gas insulation switchgear (GIS)
  • ZHW Series HV Gas insulation switchgear (GIS)
ZHW Series HV Gas insulation switchgear (GIS)
discuss personally
Model
ZHW-145/3150
ZHW-145/2000
ZHW-126/3150
ZHW-126/2000
ZHW-72.5/3150
ZHW-72.5/2000
Basic info
Brand ROCKWILL
Model NO. ZHW Series HV Gas insulation switchgear (GIS)
Rated voltage 145kV
Rated normal current 3150A
Rated frequency 50/60Hz
Rated peak value withstand current 104kA
Rated short-time withstand current 40kA
Series ZHW Series
Product Detail

Overview

Small in Size To compare with AIS Substation, it can save 60 - 70% of the floor area, best way for saving current increasingly tense land resources;

Fast Way To transport the Combined bay. All HGIS components have been debugged and tested in the Factory. Only a few line connections and routine tests are required on - site, therefore, the on - site installation time of single bay can be ≤ 10h; 

Stability in Performance The Circuit Breaker is the HGIS core component, which is horizontally arranged, with low center of gravity, better stability and better seismic performance. It is especially suitable for earthquake - prone areas (Have accepted and passed the ACS test). The Circuit Breaker can be used in extremely harsh environments (Sandstorm, heavy pollution, etc.), thanks for its fully enclosed transmission way.

Convenience in Replacement It is designed solely with anchor bolt fixing and overhead incoming and outgoing lines, with independent bays, therefore, the replacement of single bay can be completed within 4h. Also not be troubled as GIS Substation, which can be troubled by the long power outage time caused by GIS Substation failure, the transformation and expansion of the Substation is relatively simple and convenient, especially suitable for the AIS Substation. It only needs simple civil foundation work with small investment, so it's worth it;

Reliable in Quality The HGIS is specialized designed is relative perfectly, with SF6 gas insulation for its excellent insulation and breaking performance.

Lower Life - cycle Costs Refer to GIS and AIS, the HGIS has the multi features, such as minimum maintenance workload, minimum construction difficulty, shortest construction time, minimum overhaul difficulty, lower equipment cost, lower operation cost and shorter construction period for reconstruction and expansion. 


If you need to know about more parameters , Please check the model selection manual.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!