12kV 17.5kV 24kV outdoor Gas Insulated Ring Main Unit

  • 12kV 17.5kV 24kV outdoor Gas Insulated Ring Main Unit

Key attributes

Brand ROCKWILL
Model NO. 12kV 17.5kV 24kV outdoor Gas Insulated Ring Main Unit
Rated voltage 24kV
Rated normal current 630A
Rated frequency 50/60Hz
1min Power frequency withstand voltage 55kV
Series OMR

Product descriptions from the supplier

Description

Description :

OMR is a ring main unit for the secondary distribution network. RMU(OMR) can be supplied as a 3 or 4-way  standard configurations with additional equipment according to customer specification. OMR can be supplied in 10  different configurations (Such as CVC, CCV, CVV, CFF, CCC, VVV, CCVV etc) suitable for most switching  applications in 12/24 kV distribution networks.  

It is extendable and combined with our own developed technology concept, which is flexible, modular compact  switchgear, they represent a complete solution for 12/24 kV secondary distribution networks. OMR have identical user interfaces. 

OMR is a completely sealed system with a stainless steel tank containing all live parts and switching functions.  A sealed steel tank with constant atmospheric conditions ensures a high level of reliability as well as personnel  safety and a virtually maintenance-free system. 

The OMR concept offers a choice of either switch-fuse combination or circuit-breaker with relay for protection of  the transformer. OMR can be supplied with an integrated remote control and monitoring unit. This product is in conformity with the standards: IEC62271-200, IEC60420

Technical feature :

  • Good insulation performance, compact structural design;

  • High protection level, fully sealed and fully insulated structure;

  • Fast operation performance, high degree of intelligence;

  • Good environmental protection performance, and convenient installation.

Main technical parameters:

image.png

Single Line Diagram:

企业微信截图_17427952361385.png

Structure Diagram:

image.png

image.png


Documentation Resource Library
Restricted
OMR Type Outdoor Gas Insulated Ring Main Unit
Catalogue
English
Consulting
Consulting
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • GIS Dual Grounding & Direct Grounding: State Grid 2018 Anti-Accident Measures
    1. Regarding GIS, how should the requirement in Clause 14.1.1.4 of the State Grid’s "Eighteen Anti-Accident Measures" (2018 Edition) be understood?14.1.1.4: The neutral point of a transformer shall be connected to two different sides of the main mesh of the grounding grid via two grounding down conductors, and each grounding down conductor shall meet the thermal stability verification requirements. Main equipment and equipment structures shall each have two grounding down conductors connected to
    12/05/2025
  • China's first ±550 kV DC GIS completes long-term energized test.
    Recently, a ±550 kV DC GIS (Gas-Insulated Switchgear), jointly developed by a Chinese GIS manufacturer and multiple companies, successfully completed a 180-day outdoor long-term energized reliability test at the Xi’an High Voltage Apparatus Research Institute. This marks the first time in the industry that a next-generation ±550 kV DC GIS has passed such a long-term energized evaluation.The ±550 kV DC GIS had already undergone comprehensive performance verification tests at the Xi’an High Voltag
    11/25/2025
  • First Fully Unmanned GIS Inspection at ±800kV UHV Station
    On October 16, a ±800 kV ultra-high-voltage (UHV) transmission project completed all its maintenance tasks and was fully re-energized. During this period, a regional power company successfully conducted the first-ever fully unmanned inspection of the GIS (Gas-Insulated Switchgear) room at a UHV converter station within this power system.As a key component of China’s “West-to-East Power Transmission” strategy, the ±800 kV UHV project has been in operation since 2016 and has delivered nearly 400 b
    11/21/2025
  • China's first 252 kV mixed-gas double-break GIS product successfully passes on-site power frequency withstand voltage test.
    Recently, Chinese GIS manufacturers announced exciting news: the first ZF11C-252(L) mixed-gas double-break GIS product developed by a Chinese GIS manufacturer successfully passed its on-site power frequency withstand voltage test on the first attempt at a project site. This achievement marks another milestone for Chinese GIS manufacturers in advancing green and high-quality development of power grids.The ZF11C-252(L) mixed-gas double-break GIS that passed the test represents the culmination of t
    11/18/2025
  • Testing Methods for Newly Installed 35 kV GIS Gas-Insulated Switchgear
    GIS (Gas-Insulated Switchgear) offers advantages such as compact structure, flexible operation, reliable interlocking, long service life, maintenance-free operation, and small footprint. It also possesses many irreplaceable advantages in insulation performance, environmental friendliness, and energy saving, and is increasingly applied in industrial and mining enterprises, airports, railways, subways, wind power stations, and other fields.A certain enterprise’s 35 kV indoor substation was origina
    11/18/2025
  • Analysis and Handling of a Breakdown Discharge Fault in a 550 kV GIS Disconnector
    1.Description of the Fault PhenomenonThe disconnector fault in a 550 kV GIS equipment occurred at 13:25 on August 15, 2024, while the equipment was operating under full load with a load current of 2500 A. At the moment of failure, the associated protection devices acted promptly, tripping the corresponding circuit breaker and isolating the faulty line. System operating parameters changed significantly: the line current dropped abruptly from 2500 A to 0 A, and the bus voltage instantly decreased
    11/17/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.