• 12/24kV Solid Insulated Metal-enclosed ring main unit
12/24kV Solid Insulated Metal-enclosed ring main unit
discuss personally
Model
CKSS-12
Basic info
Brand ROCKWILL
Model NO. 12/24kV Solid Insulated Metal-enclosed ring main unit
Rated voltage 12kV
Rated frequency 50/60Hz
Series CKSS
Product Detail
Description

CKSS-12/24 series of ring main unit is insulated metal common tank enclosed switchgear, consisting of load break switch unit, load break switch fuse combination electrical unit, vacuum circuit breaker unit, and the incoming line unit of bus. It adopts a range of advanced technologies and materials, with excellent electrical and mechanical properties, less affected by environment and climate, in small size, easy to install, easy to operate, with no need of maintenance, and can be flexibly combined. Its clear and intuitive design ensures simple and direct operation, the feeder's connection capacity is large, suitable for a variety of wiring systems.

Feature

  • Excellent solid insulation performance: Adopts advanced solid insulating materials such as epoxy resin to fully encapsulate internal high-voltage live components, featuring high insulation strength that can effectively withstand electrical stress at 12kV or 24kV voltage levels. Unlike traditional insulation methods, it is not affected by environmental factors such as humidity, dust, and pollution, greatly reducing the risk of flashover and breakdown, and ensuring long-term stable operation of the equipment in complex environments.
  • Compact and space-efficient design: The metal-enclosed structure is extremely compact with a small footprint, suitable for installation in space-constrained locations such as urban distribution stations, commercial building switchrooms, and industrial park substations. By optimizing the internal layout, various functional modules are closely integrated, reducing installation space requirements while facilitating transportation and on-site installation and commissioning, thus improving the utilization efficiency of the site space.
  • Multiple safety protection mechanisms: The cabinet body adopts a fully enclosed metal shell, which can effectively shield the internal high-voltage electric field and prevent accidental electric shock to personnel. It is equipped with complete internal mechanical and electrical interlocking devices to strictly prevent dangerous situations such as incorrect switching operations, on-load switching, and entry into live compartments. Some products are also equipped with live display devices to intuitively show the live status of the equipment in real-time, further ensuring the safety of operators and equipment.
  • Low maintenance and long service life: The solid insulating materials have strong stability, and internal components are sealed in the metal shell, effectively isolating external erosion, reducing component aging and failures caused by environmental factors, and achieving long-term maintenance-free operation. Under normal circumstances, the service life of the equipment can reach 20 years or more, reducing the life-cycle maintenance costs and equipment replacement frequency, and providing users with reliable long-term investment returns.
  • Flexible power distribution adaptability: Supports multiple wiring methods such as ring network power supply and radial power supply, and can be easily connected with 12kV or 24kV transformers, cables, and other power equipment, flexibly adapting to different medium-voltage distribution network topologies. It can easily meet the needs of various power distribution scenarios, whether for urban power grid upgrading projects or complex power supply requirements in industrial plants.
  • Outstanding environmental performance: Different from SF6 gas-insulated ring main units, this equipment does not use SF6 gas, avoiding potential environmental hazards caused by SF6 gas leakage, and conforming to the current concept of green environmental protection. It is especially suitable for the construction of power distribution facilities in areas with strict environmental requirements, such as ecological protection zones and urban core areas.
 

Unit code

Meaning

C

Standard single casing load break switch unit

F

Load break switch and fuse combination

V

Apparatus unit

D

Cable unit(without switch)

+

Side casing of busbar

-

Top casing of busbar

SL

Bus couple unit

M

Metering unit

PT

PT unit

1K2(4)

Double-sleeve outgoing load break switch unit

Technical Sheet

ltem

Unit

Load break switch unit

Combination apparatus

Fuse unit

Rated voltage

kV

12/24

12/24

12/24

Rated frequency

Hz

50

50

50

Rated current

A

630

Depend on rated current of fuse

630

P.F.withstand voltage (phase to phase.phase to earth)

kV

42/65

42/65

42/65

Ated insulation levels

P.F.withstand voltage(Across open contacts)

48/79

48/79

48/79

P.F.withstand voltage (Control and auxiliary circuit)

2/2

2/2

2/2

Lightning impulse withstand voltage (phase to phase, phase to earth)

75/125

75/125

75/125

Across open contacts

85/145

85/145

85/145

Ogauge pressure test

Pass

Pass

Pass

Rated short time withstand current

kA

20/4s/20/3s

20/4s/20/4s

Rated peak withstand current

kA

63

——

63

Rated short circuit making current

kA

50 or 63

Subject to high-voltage fuse

50

Rated short circuit breaking current

kA

Subject to high-voltage fuse

20/20

Rated transform current

A

1750/1400

Rated active load breaking current

A

630

Rated Closed loop breaking current

A

630

630

Mechanical life

Load break switch/breaker

Time

5000

5000

10000

Isolating switch/earthing switch

5000

5000

5000

Loop resistance

μΩ

≤120

≤120

Inflation pressure

Rated inflation pressure(absolute pressure)

bar

1.3

1.3

1.3

Minimum inflation pressure(absolute pressure)

1.2

1.2

1.2

Relative rate leakage of gas

%

≤0.02

≤0.02

≤0.02

Remark: l :Neutral point earthing system through low resistance

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry