• Photovoltaic power generation inverter isolation transformer
Photovoltaic power generation inverter isolation transformer
discuss personally
Model
SGG-250kVA
SGG-320kVA
Basic info
Brand ROCKWILL
Model NO. Photovoltaic power generation inverter isolation transformer
Rated frequency 50/60Hz
Rated capacity 250kVA
Series SGG
Product Detail

Product Overview:

Photovoltaic power generation inverter isolation transformer is a technology that directly converts light energy into electrical energy by using the photogenerated volt effect at the semiconductor interface. The key element of this technology is the solar cell. Solar cells can be encapsulated and protected in series to form large-area solar cell modules. Combined with the power controller and other components, a photovoltaic power generation device is formed.

Photovoltaic transformers are generally used for solar inverters. Because the photovoltaic transformer itself has low photoelectric efficiency. Therefore, the high efficiency of the transformer is especially required.

Grid-side wiring of photovoltaic grid-connected inverter isolation transformer. Dyn11. YD5. Phase shift 120 degrees. The PV isolation transformer can be set to work during the day. Stop at night to reduce no-load loss of electrical energy.Three-phase photovoltaic transformer parameters for reference.

Key Features:

  • Dedicated to PV systems, it achieves electrical safety isolation, blocks grid interference, provides a pure power environment for inverters, and ensures stable operation.

  • Supports flexible voltage matching, adapts to the voltage requirements of various photovoltaic inverters, realizes precise voltage transformation, transmits electrical energy efficiently, and improves power generation utilization.

  • Adopts high - quality iron core and winding technology, featuring low loss, high efficiency, and low temperature rise, which extends the equipment service life and reduces the operation and maintenance costs of the photovoltaic system.

  • Possesses strong anti - interference capability, suppresses harmonics, surges, etc., ensures the output power quality of the inverter, and is suitable for complex photovoltaic application scenarios.

  • Compact structure, suitable for the spatial layout of photovoltaic power stations; excellent protection performance, adaptable to outdoor temperature differences, humidity and other environments, and operates stably and reliably.

Technical data:

Conditions of Use. Working environment temperature: 15~+50℃

Operating ambient temperature:20—90%RH

Atmospheric pressure in the working environment:860 hpa---1060 hpa

Storage/transport temperature. 20℃-- +55℃

Main technical features:AA

Rated capacity:5KVA—1000KVA

Input Voltage: Rated voltage 270V or 315V

Input current by actual voltage

Output voltage: Rated voltage: 380V or 400V

The output current is based on the actual voltage

Connection mode :dyn11

Efficiency: ≤98.5%

Frequency: 50HZ/60HZ

Insulation resistance :25A less than 500MΩ

Induction withstand voltage: 125HZ/800y/60

Insulation Chip Class: H (Temperature Resistance 180 °C)

Noise :≤30dB)

Temperature rise :≤ allows for a temperature rise of 115k

Impedance Voltage Drop: ≤4%

Structure: Forced air cooling, waiting for the temperature controller, according to customer requirements, reach a certain temperature, the fan will be automatically opened.

Degree of protection :IP00

Anti-interference mode: copper foil isolation shielding grounding:

Waveform Distortion :No additional waveform distortion.

Electrical strength: Power frequency sinusoidal voltage 3000V, which lasts for one minute, without breakdown and flashover

Insulation resistance (input and output to ground) Test voltage at least 1000V DC insulation resistance greater than 1000 Overload capacity Twice the rated current for one minute..

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Neutral line current is actually greater than live line current? Why?
Neutral line current is actually greater than live line current? Why?
In a three-phase four-wire power distribution system, it is a consensus among industry insiders that the neutral line current should be very small when the three-phase loads are balanced. However, more and more phenomena are subverting this concept.For example, the advertising light boxes around a building use fluorescent lighting with electronic ballasts. The loads on the three-phase lines are balanced, with each phase current being approximately 90A, but the neutral line current reaches 160A.I
RW Energy
08/01/2025
Difference Between EMF and Voltage
Difference Between EMF and Voltage
One of the key differences between electromotive force (EMF) and voltage is that EMF refers to the energy supplied to charges, while voltage represents the energy required to move a unit charge from one point to another. Other distinctions between the two are detailed in the comparison chart below.Comparison ChartDefinition of VoltageVoltage is defined as the energy required to move a unit charge from one point to another. It is measured in volts (V) and denoted by the symbolV. Voltage is induce
Dyson
08/01/2025
Case Analysis: Economy and Reliability of 110kV All-Aluminum Winding Power Transformers
Case Analysis: Economy and Reliability of 110kV All-Aluminum Winding Power Transformers
Currently, the market price of copper remains high, fluctuating in the range of 70,000 to 80,000 yuan per ton. In contrast, the price of aluminum stays low, lingering in the range of 18,000 to 20,000 yuan per ton. For power transformers, replacing copper windings with aluminum windings in design will undoubtedly significantly reduce the material cost of products, bringing substantial cost savings to end customers.For a long time, it has been widely believed in the industry that aluminum windings
Ron
08/01/2025
What should be done if the neutral line current is too large?
What should be done if the neutral line current is too large?
As we all know, if an electrical line exceeds its rated load, it will overheat severely, and may even cause a fire. For safety reasons, overcurrent protection devices are therefore installed on lines. Whenever the current in the line exceeds the rated value, the overcurrent protection device will automatically cut off the line to prevent fire. The "excessive neutral line current" mentioned here refers to the phenomenon where the neutral line current is excessively high (more than 1.5 times the p
RW Energy
08/01/2025
What does the lifting inspection of a transformer core include?
What does the lifting inspection of a transformer core include?
1.Environmental Requirements for Transformer Core-Lifting Inspection1.1 General Environmental ConditionsCore - lifting operations are preferably carried out indoors. For large transformers that have to be operated outdoors due to specific conditions, sufficient measures must be taken to prevent moisture and dust contamination.Core - lifting should not be conducted during rainy or snowy weather or when the relative humidity exceeds 75%.The ambient air temperature during core - lifting should not
Rockwell
08/01/2025
Transformer operation and maintenance
Transformer operation and maintenance
Transformer Operating TemperatureDuring operation, transformers generate copper losses and iron losses, both of which are converted into heat, causing the transformer’s temperature to rise. Most transformers in China use Class A insulation. Due to heat transfer characteristics, significant temperature differences exist between different components during operation: winding temperature is the highest, followed by the core, and then the temperature of the insulating oil (with upper-layer oil being
Encyclopedia
07/31/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!