transformator rectificativ duplex secus et in oleo immersus 10kV 35kV

  • 10kV 35kV dry type, oil immersed double split rectifier transformer

Attributa principalia

Marca ROCKWILL
Numerus Modeli transformator rectificativ duplex secus et in oleo immersus 10kV 35kV
Votum nominatum 11kV
Frequenta nominata 50/60Hz
Capacitas nominata 2500kVA
Series ZSF

Descriptiones productorum a fornitori

Descriptio

Descriptio Producti

Haec series productorum includit transformatores rectificantes duplices scissos ad tensio 10kV et 35kV, quibus utrumque designatum sicca et immissa oleo praebent. Hi constructi sunt ut duos eodem modo formatos, isolatos et phase-shifted secundarios exitus pro systematibus rectificantibus 12-pulsuum vel superioribus praebere. Per harmonicis currentibus in parte primaria significanter reductis, hi transformatores qualitatem potentiae augent, fiduciam systematis meliorent, et solutio idealis conversionis potentiae pro mediis tensibus, altis potentiis industriae applicationibus requirantibus puram et stabiliter directam potentiam praebent.

Characteres Technici Principales

Secundaria Bobina Duplex Scissa:

  • Character principalis est duo secundaria bobinae idem formatas, quae necessarium dispacementum phasale (exempli gratia, 30-degree shift) pro multi-pulse rectification praebent, efficaciter harmonicas characteristicales cancelantes.

Optiones Technologiae Insulationis Duplex:

  • Sicca: Utilizat resina epoxy aut VPI (Vacuum Pressure Impregnation) technologiam. Praebet altam securitatem sine periculo effusus olei, idealem pro installationibus indoor sensibilis ignis sicut minae aut aedificia.

  • Immissa Oleo: Praebet refrigerationem et fortitudinem insulationis superiores, id aptum pro applicationibus altis potentiis, continuo opere in duris ambientibus outdoor aut industrialibus.

Harmonic Mitigation Excellentis:

  • Specificiter designati ut resistere et minimare effectus negativos currentium harmonicorum generatarum a rectifieribus, diminuendo distortionem tensionis et conformitate cum standardibus qualitatis grid.

Alta Fiducia et Robusta Constructio:

  • Constructi ex materialibus altae qualitatis et processibus manufacturae rigidos. Versiones siccae offerunt altam classem thermalis insulationis, dum versiones immissae oleo characterisantur robustis tankis et efficientibus systematibus refrigerationis pro longa vita servitii.

Configuratio Flexibilis:

  • Disponibilia in variis ratingibus potentiae et possunt customizari cum specificis levelibus tensionis, valori impedentiae, et BIL (Basic Impulse Level) ut unica requirementa systematis satisfaciant.

Tabula Parametri Technici Series ZSF 10kV, 35kV Immissa Oleo Duplices Scissi Rectifier Transformer

Product Model

Rated Capacity (kVA)

Voltage Combination and Tap Range

Connection Group

Short-Circuit Impedance (%)

Weight (kg)

Gauge (mm)

Outline Reference Dimensions (Length * Width * Height mm)

High Voltage (kV)

High Voltage Tap Range (%)

Low Voltage (kV)

Core Weight

Oil Weight

Total Weight

ZSF-400

400

6

6.3

10

10.5

11

±5%±2×2.5%


0.10~3.3

Dy11

Dy5

Dd0

Dd6

4.0

1000

440

1850

550

1700 * 730 * 1450

ZSF-500

500

1220

460

2160

550

1900 * 730 * 1550

ZSF-630

630

6.0

1387

505

2390

550

2025 * 700 * 1680

ZSF-800

800

1870

690

3220

820

2180 * 1040 * 1785

ZSF-1000

1000

2090

783

3515

820

2280 * 1260 * 1840

ZSF-1250

1250

2200

966

4470

820

2000 * 1300 * 1840

ZSF-1600

1600

2723

1150

4590

820

2340 * 1300 * 1990

ZSF-2000

2000

3150

1230

6770

1070

2490 * 1365 * 2110

ZSF-2500

2500

7.0

3735

1450

7675

1070

2450 * 2150 * 2155

ZSF-3150

3150

4368

1536

8910

1070

2455 * 2200 * 2215

ZSF-3500

3500

4845

2140

9200

1070

2590 * 2510 * 2335

ZSF-4000

4000

5070

2280

9700

1070

2640 * 2800 * 2405

ZSF-5000

5000

8.0

5900

3100

12900

1475

2700 * 3250 * 2440

ZSF-6300

6300

7000

3270

14300

1475

2955 * 3220 * 2440

ZSF-8000

8000

7500

3600

17300

1475

2960 * 3240 * 2480

ZSF-9000

9000

8550

3700

19800

1475

2980 * 3540 * 2570

ZSF-10000

10000

9200

3980

22800

1475

3020 * 3925 * 2660

Typicae Applicationes Scenarii

  • Systemata DC Industrialia: Alimentantia magnas machinas variabilis velocitatis pro molendinis, funibus metallicis et extrusoribus, ubi designum duplex scindens certificat operationem motorum lenem et protegit electronica sensibilia ab harmonicis.

  • Plantae Electrochimicae: Servientes ut fontes alimentorum pro unitatibus rectificatorum in productione chloro-alkali, smeltingu aluminii et aliis processibus electrolysis quae requirunt potentiam DC alta correntis.

  • Banci Testuum et Laboratoria Simulationis: Praebentes alimentum DC stabilis et eximium pro testibus instrumentorum electricorum, electronicorum potentiae et in contextibus R&D.

  • Alimentatio Tractiva: Usa in substationibus systematum ferroviariarum ad praebendum alimentum DC rectificatum.

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026

Solutiones Relatae

  • Design Solution of 24kV Siccum Aera Insulatum Ring Main Unit
    Combinatio Solidi Insulationis Adiuvantis + Insulationis Aereae Siccae repraesentat directionem pro RMU 24kV. Per requirementa insulationis cum compactitate equilibrata et adiuvante solidum insulationis, testes insulationis sine magnificatione significativa dimensionum inter phasos et inter phasos et terram transigi possunt. Inclusio columnae pole solidificat insulationem pro interruptore vacuo et conductoribus eius coniunctis.Maintinendo spatium phasorum exiens 24kV ad 110mm, intensitas electri
    08/16/2025
  • Optimizatio Design Schematum pro Unitate Circulorum Principalium Aere Insulata 12kV ad Minuendam Probabilitatem Disruptionis Emissionis
    Cum celeri progressus industriae electricitatis, conceptus ecologicus de carbonis minore, energiae servanda, et conservatione ambientis profundissime integratus est in designum et fabricam productorum electricorum pro distributione et generatione electricitatis. Unitas Distributiva Circuli (RMU) est dispositivum electricum clavem in retibus distributionis. Securitas, conservatio ambientis, fides operativa, efficacia energetica, et oeconomia sunt tendentiae inevitabiles in eius progressu. RMUs tr
    08/16/2025
  • Analyse communium problematum in unitatibus principali circuitu isolatis gas 10kV (RMUs)
    Introductio:​​RMUs insulati gaseis 10kV sunt amplissime usitati propter multas suas utilitates, sicut quod sint perfecte clausi, habeant excellentem insulativam qualitatem, non requirant maintenance, sint compacti, et praebent installationem flexibilem et commodam. In hoc stadio, paulatim facti sunt nodus criticus in rete distributionis urbano anulari et iocabuntur partem significativam in systemate distributionis electricitatis. Difficultates in RMUs insulatis gaseis possunt graviter impingere
    08/16/2025
Instrumenta Libera Cognata
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum