160kVA-10000kVA Triformis Transformer Immersus in Oleo Rectificatorius

  • 160kVA-10000kVA Three-phase Oil-immersed Rectifier Transformer

Attributa principalia

Marca ROCKWILL
Numerus Modeli 160kVA-10000kVA Triformis Transformer Immersus in Oleo Rectificatorius
Votum nominatum 11kV
Frequenta nominata 50/60Hz
Capacitas nominata 2000kVA
Series ZS

Descriptiones productorum a fornitori

Descriptio

Descriptio Producti

Noster transformator rectificans oleo-immersus triphasalis de 160kVA ad 10000kVA est ingeniosus ad obviandum exigentiis severis industriae electricae, servens ut nucleus conversionis potestatis crucialis pro systematibus DC industrialibus. Specialiter designatus est ad praebendum fontem potestatis DC stabilis et fidelis pro variis processibus electrochemicalibus et industrialibus. Hic robustus transformator convertit tensionem lineam AC in requiritam tensionem AC isolatam et phase-shifted, quae deinde rectificatur in DC, assecurans operationem optimam et efficientiam pro tuis applicationibus maxime exigentibus.

Characteres Technici Principales

  • Constructio Robusta pro Ambientibus Exigentibus:Constructa cum tank heavy-duty et insulatione oleo-immersa altae qualitatis, assecurans excellentem dissipationem caloris, resistentiam contra corrosionem, et fidem longinquentem in ambientibus industrialibus duris.

  • Designum Altius Efficiens et Minima Perdita:Utilizat materiales nuclei praepositos (sicut ferrum silicium alti gradus vel alluvium amorphum) et technicas winding precisionis ad minimizandas perditas no-load et load, significanter reducens costus operationales.

  • Capacitas Superior Sustinentis:Designata ad gerendas altas currentes harmonicas et fluctuationes frequentes oneris typicas in circuitis rectificatorum, praeveniens supercalorem et assecurans operationem stabilem.

  • Configurationes Customizabiles:Disponibilis in lato ambitu potentiae ab 160kVA ad 10,000kVA. Offert optiones flexibiles pro gradibus tensionis, vector groups, et tap changers (on-load vel off-circuit) ad perfecte congruentes cum requisitis specificis tui systematis rectificatoris.

  • Safetia et Protectio Aucta:Aequata cum dispositivis protectivis comprehensivis sicut valvae relevari pressionis, indicatores temperature, et relays Buchholz (detectors gas) pro operatione secura et monitorata.

Tabula Parametrorum Technicorum Transformatoris Rectificantis Oleo-Immersi Series ZS

Product Model

Rated Capacity (kVA)

Voltage Combination and Tap Range

Connection Group

Short-Circuit Impedance (%)

Weight (kg)

Gauge (mm)

Outline Reference Dimensions (Length * Width * Height mm)

High Voltage (kV)

High Voltage Tap Range (%)

Low Voltage (kV)

Core Weight

Oil Weight

Total Weight

ZS-160

160

6

6.3

10

10.5

11

±5%

±2×2.5%


0.10~3.3

Dy11

Dy5

Dd0

Dd6

4.0

415

158

770

550

1180 * 708 * 1050

ZS-250

250

650

250

980

550

1280 * 710 * 1150

ZS-315

315

849

360

1480

550

1522 * 728 * 1250

ZS-400

400

950

400

1750

550

1700 * 730 * 1250

ZS-500

500

1120

420

1960

550

1900 * 730 * 1350

ZS-630

630

6.0

1287

455

2190

550

2025 * 700 * 1380

ZS-800

800

1770

590

2920

820

2180 * 1040 * 1485

ZS-1000

1000

1890

683

3415

820

2280 * 1260 * 1540

ZS-1250

1250

2100

866

3570

820

2000 * 1300 * 1640

ZS-1600

1600

2623

1000

4490

820

2340 * 1300 * 1790

ZS-2000

2000

3050

1030

5270

1070

2490 * 1365 * 1810

ZS-2500

2500

7.0

3635

1350

6775

1070

2450 * 2150 * 1955

ZS-3150

3150

4168

1436

7610

1070

2455 * 2200 * 2015

ZS-3500

3500

4745

1940

8900

1070

2590 * 2510 * 2135

ZS-4000

4000

4870

2080

9300

1070

2640 * 2800 * 2205

ZS-5000

5000

8.0

5800

2900

11900

1475

2700 * 3250 * 2240

ZS-6300

6300

6900

3170

13300

1475

2955 * 3220 * 2240

ZS-8000

8000

7200

3500

16300

1475

2960 * 3240 * 2280

ZS-9000

9000


8150

3600

17800

1475

2980 * 3540 * 2370

ZS-10000

10000

8800

3680

20800

1475

3020 * 3925 * 2460

Typicae Applicationes Scenarii

  • Praedia Electrochemica: Fornit potentiam DC magnae currentis necessariam pro processibus sicut producere chlor-alkali, fusio aluminii, et fabricatio foliorum cuprei.

  • Fornaces DC Industriales: Servit ut praebitor potestatis pro fornicibus electricis arcuum magnarum et fornicibus lagenaribus utentibus in fusione metallorum et fonderiis.

  • Potestas Tractionis: Usa in substationibus ad praebendam potentiam DC pro systematibus transitus urbis ferroviariis, sicut metropolitanae et tramvai.

  • Systemata Rectificatorum Magnae Potentiae: Agit ut cor systematum praebendorum potestatis DC pro calefactione plasmatica, motoribus magnis, et praecipitatoribus electrostaticis altae tensionis.

160kVA-10000kVA Three-phase Oil-immersed Rectifier Transformer for Electrical Industry.png

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026

Solutiones Relatae

  • Design Solution of 24kV Siccum Aera Insulatum Ring Main Unit
    Combinatio Solidi Insulationis Adiuvantis + Insulationis Aereae Siccae repraesentat directionem pro RMU 24kV. Per requirementa insulationis cum compactitate equilibrata et adiuvante solidum insulationis, testes insulationis sine magnificatione significativa dimensionum inter phasos et inter phasos et terram transigi possunt. Inclusio columnae pole solidificat insulationem pro interruptore vacuo et conductoribus eius coniunctis.Maintinendo spatium phasorum exiens 24kV ad 110mm, intensitas electri
    08/16/2025
  • Optimizatio Design Schematum pro Unitate Circulorum Principalium Aere Insulata 12kV ad Minuendam Probabilitatem Disruptionis Emissionis
    Cum celeri progressus industriae electricitatis, conceptus ecologicus de carbonis minore, energiae servanda, et conservatione ambientis profundissime integratus est in designum et fabricam productorum electricorum pro distributione et generatione electricitatis. Unitas Distributiva Circuli (RMU) est dispositivum electricum clavem in retibus distributionis. Securitas, conservatio ambientis, fides operativa, efficacia energetica, et oeconomia sunt tendentiae inevitabiles in eius progressu. RMUs tr
    08/16/2025
  • Analyse communium problematum in unitatibus principali circuitu isolatis gas 10kV (RMUs)
    Introductio:​​RMUs insulati gaseis 10kV sunt amplissime usitati propter multas suas utilitates, sicut quod sint perfecte clausi, habeant excellentem insulativam qualitatem, non requirant maintenance, sint compacti, et praebent installationem flexibilem et commodam. In hoc stadio, paulatim facti sunt nodus criticus in rete distributionis urbano anulari et iocabuntur partem significativam in systemate distributionis electricitatis. Difficultates in RMUs insulatis gaseis possunt graviter impingere
    08/16/2025
Instrumenta Libera Cognata
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum