• UL Listed Three Phase Pad Mounted Power Transformer
UL Listed Three Phase Pad Mounted Power Transformer
discuss personally
Model
ZGS-2500-33
ZGS-2500-11
ZGS-1000-33
ZGS-1000-11
ZGS-200-33
ZGS-200-11
Basic info
Brand Vziman
Model NO. UL Listed Three Phase Pad Mounted Power Transformer
Rated frequency 50/60Hz
Rated capacity 2500kVA
Primary voltage 33kV
Series ZGS
Product Detail

Description:

The UL-listed three-phase pad-mounted power transformer is an outdoor power distribution device compliant with the safety standards of Underwriters Laboratories (UL). It adopts a fully sealed pad-mounted structure, specially designed for medium and low-voltage power distribution systems. Its core characteristics are as follows:

Structural Standards:

  • Complies with UL 1562 (oil-immersed transformers) or UL 1836 (dry-type transformers) certifications, with a protection rating typically reaching IP65/66. It can be directly installed on concrete foundations and adapts to harsh outdoor environments (such as rain, dust, and high temperatures).

Electrical Parameters:

  • Capacity Range: Usually 50kVA to 5000kVA, meeting the load requirements of different scales.
  • Voltage Classes: The high-voltage side commonly includes 7.2kV, 12.47kV, 13.8kV, 34.5kV, etc.; the low-voltage side outputs three-phase four-wire voltages such as 208V/120V, 480V/277V, 600V (compatible with North American standards).

Insulation and Cooling:

  • Oil-Immersed Type: Uses mineral oil or environmentally friendly high-flash-point oil (such as silicone oil) as the insulation medium, combining cooling and fireproof performance (complying with UL 1203 explosion-proof standards).
  • Dry-Type (Optional): High-voltage windings are cast with epoxy resin, requiring no maintenance, suitable for scenarios with higher fireproof requirements.

Core Functions:

Power Conversion and Distribution:

  • Steps down medium-voltage power grids (e.g., 13.8kV) to low voltage (e.g., 480V), providing stable power for three-phase loads (such as motors and large equipment), while supporting multi-loop 分户配电 (household distribution).

Safety and Reliability Assurance:

  • The fully sealed structure isolates external pollution, preventing moisture and dust from affecting insulation performance.
  • Equipped with a temperature controller, pressure relief valve, and gas relay (for oil-immersed types), it automatically protects against short circuits or fire risks when oil temperature is too high (e.g., exceeding 95°C) or internal faults occur.
  • UL certification ensures products comply with North American safety codes (such as short-circuit withstand capacity and insulation voltage standards).

Grid Compatibility:

  • Supports harmonic suppression design (optional filter windings), reducing interference from non-linear loads (such as frequency converters and data center equipment) to the power grid and improving power quality.

Typical Application Scenarios:

Commercial and Industrial Sectors:

  • Data Centers/Bitcoin Mining Farms: Supplies three-phase 480V power for server clusters and mining machines, supporting high-load continuous operation. Redundant windings are often configured to ensure 99.99% power availability.
  • Manufacturing: Drives three-phase motors (such as fans, water pumps, machine tools), suitable for factory production lines, food processing plants, etc.
  • Commercial Parks: Provides three-phase power (such as elevators, air conditioning systems) and lighting distribution for shopping malls, office buildings, hospitals, etc.

Municipal and Infrastructure:

  • Residential Power Distribution: Serves as a community substation, stepping down the municipal medium-voltage grid for distribution to each unit (e.g., three-phase 208V access, converted to single-phase 120V for households).
  • Transportation Hubs: Powers escalators, lighting systems, and monitoring equipment in subway stations and airports.

New Energy and Special Scenarios:

  • Distributed Generation: Acts as a grid-connected transformer in photovoltaic and wind power projects (e.g., 34.5kV step-up side) or regulates voltage in microgrids to match loads.
  • Harsh Environments: Corrosion-resistant coatings (such as zinc-nickel alloy casings) are used in coastal areas, and seismic designs (complying with UL vibration test standards) are configured in mining areas to adapt to salt spray, dust, and other environments.

Parameter:

 

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)Under the action of an electric field, in an insulation system, discharge occurs only in some regions and does not penetrate between the conductors with the applied voltage. This phenomenon is called partial discharge. If partial discharge occurs near a conductor surrounded by gas, it can also be called corona.Partial discharge can occur not only at the edge of a conductor but also on the surface or inside an insulator. The discharge occurring on the su
Leon
07/19/2025
What types of FACTS controllers are there?
What types of FACTS controllers are there?
According to the type of connection FACTS Controller with the power system, it is classified as;Series Connected ControllerShunt Connected ControllerCombined Series-Series ControllerCombined Shunt-Series ControllerSeries-Connected ControllersSeries controllers introduce a voltage in series with the line voltage, typically using capacitive or inductive impedance devices. Their primary function is to supply or absorb variable reactive power as needed.When a transmission line is heavily loaded, the
Edwiin
07/19/2025
What are FACTS and related technologies?
What are FACTS and related technologies?
FACTS (Flexible Alternating Current Transmission System) refers to a power electronics-based system that uses static devices to enhance the power transfer capability and controllability of AC transmission networks.These power electronic devices are integrated into conventional AC grids to boost key performance metrics, including:Power transfer capacity of transmission linesVoltage stability and transient stabilityVoltage regulation precisionSystem reliabilityThermal limits of transmission infras
Edwiin
07/19/2025
What are the differences between HVAC and HVDC?
What are the differences between HVAC and HVDC?
Difference Between HVAC and HVDCElectricity generated in power plants is transmitted over long distances to electrical substations, which then distribute it to consumers. The voltage used for long-distance power transmission is extremely high, and we will explore the reasons for this high voltage later. Additionally, the transmitted power can be in either alternating current (AC) or direct current (DC) form. Therefore, power can be transmitted using either HVAC (High Voltage Alternating Current)
Edwiin
07/19/2025
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?Electricity travels long distances before reaching consumers. Power plants, often remote, supply electricity through hundreds of miles and multiple substations. High-voltage transmission reduces line losses, with both AC and DC used. Though AC is familiar via utility poles and home outlets, HVDC offers unique advantages in power transmission.The goal of power transmission is to minimize losses and costs. While both face influencing factors, HVDC has more
Edwiin
07/19/2025
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Neutral - Point Grounding Modes and Protection of Transformers in Power GridsFor systems ranging from 110 kV to 500 kV, an effective grounding method shall be adopted. Specifically, under all operating conditions, the ratio of zero - sequence reactance to positive - sequence reactance X0/X1 of the system should be a positive value and not exceed 3. Meanwhile, the ratio of zero - sequence resistance to positive - sequence reactance R0/X1should also be a positive value and not exceed 1.In 330 kV a
Leon
07/19/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.