• Non-encapsulated H-class Dry-type Power Transformers 800kVA 1000kVA 1250kVA 1600kVA 2000kVA 2500kVA
Non-encapsulated H-class Dry-type Power Transformers 800kVA 1000kVA 1250kVA 1600kVA 2000kVA 2500kVA
discuss personally
Model
SGB10-10KV-2500KVA
SGB10-10KV-2000KVA
SGB10-10KV-1600KVA
SGB10-10KV-1250KVA
SGB10-10KV-1000KVA
SGB10-10KV-800KVA
Basic info
Brand Vziman
Model NO. Non-encapsulated H-class Dry-type Power Transformers 800KVA 1000KVA 1250KVA 1600KVA 2000KVA 2500KVA
Rated capacity 2500kVA
Voltage grade 10KV
Series SGB
Product Detail

Description:
The SG(B)10 series non-encapsulated H-class dry-type power transformers integrate German (MORA) dry-type transformer process technology, ensuring full compliance with fireproof, waterproof, and environmental protection standards. Engineered as ideal solutions for distribution systems, they excel in safety-critical applications, including subways, shipbuilding, mining, chemical industries, power utilities, and personnel-dense buildings, as well as environments with special safety requirements.

Feature

  • Maintenance-free Design: The non-encapsulated windings allow direct visual inspection, eliminating the need for preventive tests. This extends the maintenance cycle to 5 years and reduces the full life-cycle cost by 30%.

  • Intelligent Monitoring Integration: Equipped with built-in winding temperature sensors and RS485 communication interfaces, it supports remote monitoring and early warning. The fault response time is shortened to seconds, significantly reducing operational and maintenance costs.

  • Superior Insulation and Heat Dissipation Performance: Adopts H-class insulation materials (temperature resistance up to 180℃), combined with non-encapsulated open-winding design, which enhances heat dissipation efficiency by 30%. It can stably operate under 150% rated capacity overload, perfectly suitable for high-load fluctuation working conditions.


Model and Meaning:

企业微信截图_17230768291792.png

Parameter:


image.png


Notes: The Dimension and weight will be changed according to the requirements.


What is an Unencapsulated Class H Dry-Type Power Transformer?

Basic Definitions:

  • Non-encapsulated: It means that the coils of the transformer are not subjected to the traditional encapsulation treatment but are directly exposed to the air. This design can improve the heat dissipation efficiency and extend the service life.

  • H-Class Insulation: H-Class insulation materials refer to those insulation materials that can withstand a maximum temperature of 180°C. They possess excellent heat resistance and electrical properties.

Structural Characteristics:

  • Coil Structure: The non-encapsulated structure is adopted, with the coils being directly exposed to the air, which is beneficial for heat dissipation.

  • Insulation Materials: H-Class insulation materials such as NOMEX paper and fiberglass are used, featuring excellent heat resistance and electrical properties.

  • Iron Core: It is usually made of laminated high-quality silicon steel sheets, with the characteristics of low loss and low noise.

  • Cooling Methods: Generally, natural air cooling (AN) or forced air cooling (AF) is employed. The appropriate cooling method is selected according to specific application requirements.


Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
What are the typical connection methods for 35kV distribution lines?
What are the typical connection methods for 35kV distribution lines?
Typical Wiring Diagram of 35kV Line Radial π ConnectionWhen a 35kV line adopts a radial power grid structure, a single - side power supply or a double - side power supply radial type can be used according to the situation of the power supply points, and a loop - out interval is reserved at the end of the line.Typical Wiring Diagram of 35kV Line Radial T - ConnectionFor double - radial lines, it is advisable to select a double - side power supply. When the power supply points do not meet the r
Leon
07/18/2025
Why are the ground fault point and the accident point not at the same location?
Why are the ground fault point and the accident point not at the same location?
Fault Transfer VoltageIn low - voltage distribution systems, there is a type of personal electric shock accident where the accident occurrence point and the system fault point are not at the same location. This kind of accident occurs because after a ground fault happens elsewhere, the generated fault voltage is conducted to the metal casings of other equipment through the PE wire or PEN wire. When the fault voltage on the metal casing of the equipment is higher than the human - body safe voltag
Leon
07/18/2025
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!