| Brand | Wone Store | 
| Model NO. | 10-30kW Three-phase OFF-Grid Wind&Solar Hybrid Controller | 
| Rated Output Rating | 30KW | 
| Input Voltage | DC240V | 
| Series | WIT | 
Features
Can be applied in wind, solar, wind&solar hybrid power generation system
Simple structure, complete function
Lowno-load loss byusing industrial frequency transformer
R5232/R5485/GPRS optional (Those with GPR5 can also be monitored through App.
CE certification
Applications
Application in wind, Solar, Wind&Solar hybrid power generation station.
Application in household wind&solar hybrid power generation system.
Power supply for those unmanned regions like the coastal islands, remote mountainous regions and border posts.
Technology Parameters
Model  |  
   WIT100-120  |  
   WIT100-240  |  
   WIT200-240  |  
   WIT300-240  |  
  
DC Input Parameters  |  
  ||||
Rated battery voltage  |  
   120VDC  |  
   240VDC  |  
   240VDC  |  
   240VDC  |  
  
Input overvoltage point  |  
   170VDC  |  
   340VDC  |  
   340VDC  |  
   340VDC  |  
  
Input overvoltage recovery point  |  
   165VDC  |  
   330VDC  |  
   330VDC  |  
   330VDC  |  
  
Input undervoltage point  |  
   108VDC  |  
   216VDC  |  
   216VDC  |  
   216VDC  |  
  
Input undervoltage recovery point  |  
   120VDC  |  
   240VDC  |  
   240VDC  |  
   240VDC  |  
  
AC Output Parameters  |  
  ||||
Output phase number  |  
   Three-Phase  |  
  |||
Rated output power  |  
   10kW  |  
   10kW  |  
   20kW  |  
   30kW  |  
  
Rated output voltage  |  
   380VAC  |  
  |||
Rated output frequency  |  
   50/60±0.5Hz  |  
  |||
THDi  |  
   <5%  |  
  |||
Efficiency  |  
  ||||
Max. conversion efficiency  |  
   ≥90%  |  
  |||
Protection Functions  |  
  ||||
DC input overvoltage/undervoltage protection  |  
   YES  |  
  |||
DC reversed connection protection  |  
   YES  |  
  |||
AC output overload protection  |  
   YES  |  
  |||
AC short circuit protection  |  
   YES  |  
  |||
Surge protection  |  
   YES  |  
  |||
Over-temperature protection  |  
   YES  |  
  |||
General Parameters  |  
  ||||
Display mode  |  
   LCD  |  
  |||
Isolation mode  |  
   Industrial frequency isolation  |  
  |||
No-load current  |  
   ≤2A  |  
   ≤1.25A  |  
   ≤2A  |  
   ≤2.5A  |  
  
Ambient temperature  |  
   -20℃ ~ +40℃  |  
  |||
Humidity  |  
   5%~95%, No condensing  |  
  |||
Noise  |  
   <60dB  |  
  |||
Cooling mode  |  
   Forced air cooling  |  
  |||
Cover protection class  |  
   IP20  |  
  |||
Product dimension (W*H*D)  |  
   500x710x500mm  |  
   600x1180x600mm  |  
  ||
Product net weight  |  
   100kg  |  
   200kg  |  
   280kg  |  
  |
Note: Part of parameters can be adjusted according to customer's specific demand.  |  
  ||||