10-167 kVA single-phase pad-mounted transformer

  • 10-167 kVA single-phase pad-mounted transformer

Key attributes

Brand Vziman
Model NO. 10-167 kVA single-phase pad-mounted transformer
Rated frequency 50/60Hz
Primary voltage 2400-19920 V
Secondary voltage 120-600 V
Capacity range 10-167 kVA
Series ZGS

Product descriptions from the supplier

Description

Descripton:

The single-phase traditional pad-mounted transformer ANSI is designed with superior performance at its core, covering a rated power range of 10-167 kVA. It offers multiple designs including MaxiShrub (ANSI Type 1), Shrubline (ANSI Type 2), and Ranch Runner to adapt to diverse application scenarios. The performance of this series of traditional transformers fully meets or exceeds the relevant standards of ANSI and NEMA. In terms of insulation media selection, the single-phase pad-mounted transformer supports filling with standard electrical-grade insulating mineral oil or fire-resistant FR3 fluid, balancing safety and flexibility.

Features:

  • Flexible Insulation Media Options: Supports FR3 fire-resistant oil to enhance fire safety ratings or electrical-grade mineral oil to meet conventional requirements.

  • Industry Standard Compliance: Performance fully meets or exceeds ANSI (except Ranch Runner front panels), NEMA standards, and DOE energy efficiency requirements.

  • Reliable Core Components: Cores and coils are optimized for high reliability and low field failure rates, available in grain-oriented steel or amorphous steel.

  • Overcurrent Protection Solutions: Standard Bay-O-Net fuses are included, with optional current-limiting fuses or weak-link designs for enhanced protection flexibility.

  • Electrical Connection Compatibility: Tinned high/low-voltage bushing terminals accommodate aluminum or copper conductors, ensuring stable connections.

  • Custom Configuration Capability: Can be specifically configured in accordance with Rural Utilities Service (RUS) specifications.

Technical Parameters:

Specifications:

  • Meets or exceeds ANSI, NEMA and DOE2016 standards

  • IEEE standards C57.12.00, C57.12.38, C57.12.28, C57.12.35, C57.12.90, C57. 91 and C57.154

  • NEMA standards, NEMA TR 1 (R2000)

  • Department of Energy Efficiency Standard, 10 CFR Part 431

  • Tank coating exceeds IEEE Std C57.12.28-2005 and C57.12.29-2005 standards (stainless steel units only)

  • Full compliance with IEEE Std C57.12.28-2005 standard enclosure integrity requirements

  • Configurable to Rural Utilities Service (RUS) specification

  • FR3 fluid or electrical grade mineral oil

  • Cores and coils designed for high reliability and low field failure rates: Available in grain-oriented electrical or amorphous steel

  • The transformer shall be designed in accordance with this specification and shall have an Average Winding Rise (AWR) of one of the following:

  • 55 °C, 55/65 °C, 65 °C

  • The applicable AWR rating shall be specified on the inquiry

  • The transformer shall be designed in accordance with this specification and shall have one of the following kVA ratings:

  • 10, 15, 25, 37.5, 50, 75, 100, 167

  • The applicable kVA rating shall be specified on the inquiry

  • Quality System ISO 9001 certified

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 10000m² Total staff: Highest Annual Export(usD): 150000000
Workplace: 10000m²
Total staff:
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Choosing Vizman Distribution Transformers: Innovative Customization to Meet Diverse Power Needs
    Distribution transformers are the heart of local electricity distribution systems. They step down voltage, enabling safe and efficient power supply to homes and businesses.At Vizman Electric Power Technology Co., Ltd., we understand the critical role of distribution transformers in the energy ecosystem. That's why we specialize in manufacturing high-quality distribution transformers, providing tailored solutions to meet diverse energy needs.1.Solutions Offered by Vizman Electric Power Technology
    04/16/2025
  • SF6 Circuit Breaker Solutions in High-Voltage Power Systems: A Case Study of VZIMAN Company
    1. Challenges in High-Voltage Power Systems1.1 High-voltage power systems, as the core of power transmission, face critical challenges: Equipment Performance Limits: With increasing voltage levels (e.g., 500kV and above), traditional circuit breakers struggle to meet high breaking capacities (over 40kA) and rapid insulation recovery requirements. Overvoltage Risks: Switching capacitive loads (e.g., capacitor banks) may cause reignition, leading to dangerous overvoltages. Poor Environmental Adapt
    05/13/2025
  • VZIMAN Company SF6 Circuit Breaker Solutions for Renewable Energy Grid Integration
    1. Current Challenges in Renewable Energy Grid Integration1.1 Grid Frequency Fluctuations and Stability IssuesThe intermittency and variability of renewable energy sources (e.g., wind and solar) lead to frequent grid frequency changes. Traditional circuit breakers struggle to respond rapidly to such dynamic loads, potentially causing equipment damage or regional blackouts. For instance, during sudden drops in wind power or abrupt solar output fluctuations, the grid must isolate faults within mil
    05/13/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.