• Single-phase pad-mounted transformers with protective functions
Single-phase pad-mounted transformers with protective functions
discuss personally
Model
ZGS-20
Basic info
Brand Vziman
Model NO. Single-phase pad-mounted transformers with protective functions
Rated frequency 50/60Hz
Primary voltage 2400-19920 V
Secondary voltage 120-600 V
Capacity range 10-167 kVA
Series ZSG
Product Detail

Descripton:

The Completely Self-Protection (CSP) single-phase pad-mounted transformer is designed with the core objective of achieving excellent performance. It integrates a directly connected primary surge arrester, a MagneX arc extinguishing chamber, or a secondary circuit breaker with a built-in primary voltage fuse. There is no need to install additional independent protective equipment, which significantly reduces the installation cost.

The power range of this series of transformers covers 10 - 75 kVA. When equipped with a MagneX arc extinguishing chamber, the power range can be expanded to 10 - 167 kVA, and its performance fully meets or even exceeds relevant standards such as ANSI and NEMA.

In addition, the CSP transformer supports two types of filling media. It can be filled with standard electrical-grade mineral insulating oil or FR3 liquid with excellent fire resistance, flexibly adapting to different usage scenarios.

Features:

  • Equipped with an internal overcurrent device and a surge arrester, it can achieve efficient overvoltage protection without the need for external independent protective components. For secondary faults and overloads, it can provide dual reliable protection through a secondary circuit breaker with weak links or an optional MagneX arc extinguishing chamber.

  • It supports the free choice of two filling media: FR3 fireproof insulating oil, which greatly enhances the fire safety level; or standard electrical-grade mineral oil to meet regular usage requirements. The product performance comprehensively surpasses industry standards and performs excellently in terms of ANSI specifications, NEMA standards, and DOE energy efficiency requirements.

  • The core and coils are deeply optimized in design. Aiming to achieve high reliability and a low failure rate, it offers two materials, grain-oriented steel and amorphous steel, to adapt to different performance needs. Both the high-voltage and low-voltage bushing terminals are tinned, making them compatible with aluminum and copper conductors to ensure stable and reliable electrical connections.

  • The exterior design takes into account both functionality and aesthetics, offering two style options: the MaxiShrub style equipped with an ANSI Type-1 front panel, or the Shrubline style with an ANSI Type-2 front panel. Both adopt a low-profile design and can better blend into the surrounding environment.

Technical Parameters:

Specifications:

  • Meet or exceeds ANSI, NEMA and DOE2016 standards

  • IEEE standards C57.12.00, C57.12.38, C57.12.28, C57.12.35, C57.12.90, C57. 91 and C57.154

  • NEMA standards, NEMA TR 1 (R2000)

  • Department of Energy Efficiency Standard, 10 CFR Part 431

  • Tank coating exceeds IEEE Std C57.12.28-2005 and C57.12.29-2005 standards (stainless steel units only)

  • Full compliance with IEEE Std C57.12.28-2005 standard enclosure integrity requirements

  • FR3 fluid or electrical grade mineral oil

  • Cores and coils designed for high reliability and low field failure rates: Available in grain-oriented electrical or amorphous steel

  • The transformer shall be designed in accordance with this specification and shall have an Average Winding Rise (AWR) of one of the following:

  • 55 °C, 55/65 °C, 65 °C

  • The applicable AWR rating shall be specified on the inquiry

  • The transformer shall be designed in accordance with this specification and shall have one of the following kVA ratings:

  • 10, 15, 25, 37.5, 50, 75, 100, 167

  • The applicable kVA rating shall be specified on the inquiry

  • Quality System ISO 9001 certified

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!