• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Quid sunt cables de controllo, et ubi communiter utuntur?

Encyclopedia
Campus: Encyclopaedia
0
China

Cablī de contrōle (Cablus de contrōle) sunt cābili spēcificī dēsignātī ad transmittendum signāla tēnui tensiōnis, praecepta de contrōle, et informationem de monitoriō. Dīversimōdō ab cābilīs electricīs, quī portant magnas crēdentias, cābili de contrōle principaliter tractant transmissionem signālōrum electricōrum. Itaque, hī solent habere sectiones āreālis conductorum minores, sāepe inter 0,5mm² et 2,5mm². Prīncipālis functio cābilōrum de contrōle est assecurāre ut diversa instrumenta in systematibus de contrōle possint accipere ac mittere signāla exactē, facientia contrōlem et monitorium praeceps.

Principālia componentia cābilōrum de contrōle:

  • Conductōrēs: Sāepe compositī ex multīs fīlīs cupreīs, usitātī ad transmittendum signāla electrica. Numerus conductōrum pendet ab specificīs exigentiīs applicationis, cum configurationibus communibus includentibus 2-cordam, 4-cordam, 6-cordam, 8-cordam, etc.

  • Strātum isolantis: Involutum circa conductōres, praebens isolationem electricam ad prohibendum interferentiam signālōrum et circuitūs brevēs. Materiales isolantēs commūnes includunt PVC (Polyvinyl Chloride), PE (Polyethylene), et XLPE (Cross-linked Polyethylene).

  • Strātum de clausura (Opertiōnale): Ad restringendum interferentiam electromagneticam (EMI) et interferentiam radiofrequentiae (RFI), multi cābili de contrōle habent strātum de clausura textilis metallicus aut folia aluminia. Clausura auctificat stabilitatem signālōrum et resistentiam ad interferentiam.

  • Tunicam exteram: Extremum strātum protectivum, sāepe factum ex materialibus bonis ad resistendum tempestātibus, abrasionī, et flammās, sicut PVC aut LSZH (Low Smoke Zero Halogen). Tunicam protegit structuram internam ab damno mechanicō, corrosione chemica, et factoribus ambientalibus.

Applicationes communes cābilōrum de contrōle

Cablī de contrōle satis usitātim ūtantur in variīs locīs industriālibus, commercialibus, et domesticīs, praesertim in scēnariīs requirēntibus contrōlem exactum et transmissionem signālōrum. Subter sunt aliquae applicationes typicās:

1. Systemata automatiā de industria

  • PLC (Programmable Logic Controller): Cablī de contrōle connectunt PLCs ad sensōres, actuators, drives variabilis frequentiae (VFDs), et alia instrumenta, facientes acquisitionem datōrum, contrōlem logicum, et operationem instrumentorum.

  • DCS (Distributed Control System): In processibus industriālibus magnārum scalārum, cablī de contrōle connectunt cameram centralis controlis ad instrumenta agri, transmittentes praecepta de contrōle et datōs de monitoriō.

  • SCADA (Supervisory Control and Data Acquisition): Cablī de contrōle faciunt monitorium et contrōlem remotum instrumentōrum distribuitorum, sicut pompae, valvae, et motōres.

2. Systemata electrica

  • Substationes: Cablī de contrōle connectunt dispositiva protectionis relē, disjunctōres, interruptōres, et alia instrumenta, transmittentes signāla de contrōle et feedback status.

  • Stationes electricae: Cablī de contrōle monitoriant et contrōlant operationem unitatum generantium, transformatorum, switchgear, et aliorum componentium criticōrum, assecurantes generationem stabilē electricitatis.

  • Systemata distributionis: Cablī de contrōle connectunt panellos distributionis, metras intelligentes, disjunctōres, et alia instrumenta, facientes managementem automationis distributionis electricae.

3. Aedificia et infrastructura

  • Systemata automatiā aedificiorum: Cablī de contrōle connectunt varia systemata de contrōle intra aedificia, sicut systemata de contrōle luminis, HVAC, systemata alarmārum incendiī, et systemata accessus, facientes managementem intelligentem et efficientiam energetica.

  • Elevatores et escalatores: Cablī de contrōle connectunt systemata controlis elevatorum, dispositiva securitatis, et botones planarum, assecurantes operationem securam et stoppage exactum.

  • Systemata securitatis: Cablī de contrōle connectunt camerae, alarmas, controllers accessus, et alia instrumenta, transmittentes signāla video et praecepta de contrōle.

4. Transportatio et trafficus

  • Systemata signali ferroviaria: Cablī de contrōle connectunt equipmenta signali tracii, controllers deflectorum, et systemata controlis automatici trainorum, assecurantes operationem securam trainorum et scheduling.

  • Aerodromi et portus: Cablī de contrōle connectunt systemata manusectus bagagii, pontes jet, equipmenta carigandi, et alia facilitates, facientes logisticam et contrōlem operationalem efficientem.

5. Communicatio et networking

  • Centra data: Cablī de contrōle connectunt servōres, commutātōres, routers, et alia instrumenta network, transmittentes signāla de contrōle et praecepta managementis ad assecurandum operationem rectam network.

  • Systemata broadcast et televisive: Cablī de contrōle connectunt camerae, equipmenta audio, commutātōres, et alia instrumenta, transmittentes signāla de contrōle et informationem synchronizationis ad assecurandum productionem et broadcast programmatum smooth.

Criteria selectiōnis pro cābilīs de contrōle

Cum eligendis cābilīs de contrōle, plūrima factōra debent considerari basāta super specificō ambiente utilitātis et exigentiīs applicationis:

  • Tensiō operativus: Cābili de contrōle solent operāri ad tēnuibus tensiōnibus, cum tensiōnibus ratificatis communibus 300/500V, 450/750V, etc. Elige cābile aptum ad maximam tensiōnem in tua applicatione.

  • Numerus conductōrum: Elige numerum cordārum appropinquātam secundum numerum signālōrum ad transmittendum. Exempli grātiā, contrōle simplis on/off potest require 2-cordam, dum systemata automationis complexa possunt nēcessitāre plus cordārum.

  • Exigentiīs de clausura: Si cābile instalarit in ambientes cum fortī interferentiā electromagneticā (exempli grātiā, iuxta VFDs aut motōres), elige cābile de contrōle clausum ad restringendum interferentiam signālōrum et assecurandum transmissionem signālōrum stabilem.

  • Conditiones ambientales: Considera ambiance installationis, inclusīve temperaturam, humiditātem, expositionem chimica, et usūram mechanicam. Pro ambientes asperīs, elige cābilīs de contrōle cum materialibus tunicārum specialibus (exempli grātiā, LSZH, PVC cum armatura ferrēa) ad auctificandam durabilitātem.

  • Performance ignea: In locīs cum altīs exigentiīs securitātis igneae (exempli grātiā, aedificia alta, stationes subway, tunnels), elige cābilīs de contrōle cum proprietātibus retardantibus flammās aut low-smoke zero-halogen ad minimizandum riscum ignis et assecurandum securitātem personālis.

Summa

Cablī de contrōle sunt componentia essentialia in systematibus modernīs automationis, electricīs, et communicationis, principaliter usitātī ad transmittendum signāla tēnui tensiōnis, praecepta de contrōle, et informationem de monitoriō. Hi satis usitātim ūnantur in automatione industriā, systematibus electricīs, infrastructurā aedificiorum, transportātiōne, et sectoribus communicationis. Cum eligendis cābilīs de contrōle, considera factōra sicut tensiō operativus, numerus conductōrum, exigentiīs de clausura, conditiones ambientales, et performance ignea ad assecurandum fidēlitātem et securitātem systematis.

Donum da et auctorem hortare

Suggestus

Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
02/05/2026
Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
01/30/2026
Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
01/29/2026
Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
01/29/2026
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum