What is Differential Protection?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China


What is Differential Protection?


Differential Protection Definition


Differential protection is a method used to clear internal faults in the stator winding of a generator or alternator.


 

779aa64b-0c2e-43bf-9710-a8f0b234c3a8.jpg


 

Current Transformers


Two sets of current transformers (CTs) are used, one on the line side and one on the neutral side, and their characteristics must match to avoid relay malfunctions.


 

Stabilizing Resistor


A stabilizing resistor in series with the relay prevents operation due to external faults or CT saturation.


 

Percentage Biasing


Percentage biasing in differential relays helps manage spill current from mismatched CTs, preventing unwanted relay operation.


 

805af702-d52a-462b-9dae-8374155c4ae2.jpg


 

Relay Operation


The differential relay operates during internal faults when the operating coil’s torque overcomes the restraint coil’s torque, ensuring reliable protection.


Give a tip and encourage the author!
Recommended
PT Fuse Slow Blow: Causes, Detection & Prevention
PT Fuse Slow Blow: Causes, Detection & Prevention
I. Fuse Structure and Root Cause AnalysisSlow Fuse Blowing:From the design principle of fuses, when a large fault current passes through the fuse element, due to the metal effect (certain refractory metals become fusible under specific alloy conditions), the fuse first melts at the soldered tin ball. The arc then rapidly vaporizes the entire fuse element. The resulting arc is quickly extinguished by quartz sand.However, due to harsh operating environments, the fuse element may age under the comb
Edwiin
10/24/2025
Why Fuses Blow: Overload, Short Circuit & Surge Causes
Why Fuses Blow: Overload, Short Circuit & Surge Causes
Common Causes of Fuse BlowingCommon reasons for fuse blowing include voltage fluctuations, short circuits, lightning strikes during storms, and current overloads. These conditions can easily cause the fuse element to melt.A fuse is an electrical device that interrupts the circuit by melting its fusible element due to heat generated when current exceeds a specified value. It operates on the principle that, after an overcurrent persists for a certain period, the heat produced by the current melts
Echo
10/24/2025
On-Line Testing for Surge Arresters Below 110kV: Safe and Efficient
On-Line Testing for Surge Arresters Below 110kV: Safe and Efficient
An On-Line Testing Method for Surge Arresters at 110kV and BelowIn power systems, surge arresters are critical components that protect equipment from lightning overvoltage. For installations at 110kV and below—such as 35kV or 10kV substations—an on-line testing method effectively avoids the economic losses associated with power outages. The core of this method lies in using online monitoring technology to evaluate arrester performance without interrupting system operation.The test principle is b
Oliver Watts
10/23/2025
SPD Installation Problems & Best Practices
SPD Installation Problems & Best Practices
Common Issues and Solutions for SPDs in Practical ApplicationsSurge Protective Devices (SPDs) are critical for protecting electrical systems from transient overvoltages. However, several common issues occur in real-world installations: Insufficient maximum continuous operating voltage (Uc): Uc is lower than the grid’s maximum possible voltage, leading to SPD overheating or failure. Voltage protection level (Up) exceeds equipment impulse withstand voltage (Uw): SPD cannot adequately protect sensi