What are the characteristics of insulating materials used in transformers?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

The insulating materials used in transformers have the following characteristics:

High resistivity and low conductivity: Insulating materials are substances with high resistivity and low conductivity, capable of effectively isolating conductors with electric charge or different potentials, ensuring that current flows in a specific direction.

  • Multifunctionality: In addition to their basic insulating function, transformer insulation materials also serve various purposes such as heat dissipation, cooling, support, arc extinction, improvement of potential gradients, moisture and mold resistance, and protection of conductors.

  • Heat Resistance Grade: The heat resistance grade of insulating materials refers to the highest temperature they can withstand in a transformer. Proper use of insulating materials can ensure a 30-year lifespan, but excessive temperatures can cause insulation aging and affect the service life.

  • Variety of Materials: Transformer insulation materials include solid insulating materials (such as insulating paper, cardboard, Nomex paper, epoxy glass cloth board, etc.), liquid insulating materials (such as transformer oil), and gaseous insulating materials (such as SF6 gas, nitrogen, etc.).

  • Performance and Application: With the advancement of technology, new insulating materials are constantly emerging. These new materials may have significant performance improvements, such as better aging resistance and higher insulation strength, thereby enhancing the reliability and service life of transformers.

  • Adapt to Different Environments: Transformers operating in high-altitude areas require special consideration for the performance of insulation materials to adapt to lower atmospheric pressure and possible low-temperature environments.

To sum up, the insulating materials of transformers are their core components, and their selection and performance directly affect the operation efficiency and safety of the equipment.



Give a tip and encourage the author!
Recommended
What are the common faults encountered during the operation of power transformer longitudinal differential protection?
What are the common faults encountered during the operation of power transformer longitudinal differential protection?
Transformer Longitudinal Differential Protection: Common Issues and SolutionsTransformer longitudinal differential protection is the most complex among all component differential protections. Misoperations occasionally occur during operation. According to 1997 statistics from the North China Power Grid for transformers rated 220 kV and above, there were 18 incorrect operations in total, of which 5 were due to longitudinal differential protection—accounting for approximately one-third. Causes of
Felix Spark
11/05/2025
Relay Protection Types in Substations: A Complete Guide
Relay Protection Types in Substations: A Complete Guide
(1) Generator Protection:Generator protection covers: phase-to-phase short circuits in stator windings, stator ground faults, inter-turn short circuits in stator windings, external short circuits, symmetrical overload, stator overvoltage, single- and double-point grounding in the excitation circuit, and loss of excitation. Tripping actions include shutdown, islanding, limiting fault impact, and alarm signaling.(2) Transformer Protection:Power transformer protection includes: phase-to-phase short
Echo
11/05/2025
What Are the Factors Influencing the Impact of Lightning on 10kV Distribution Lines?
What Are the Factors Influencing the Impact of Lightning on 10kV Distribution Lines?
1. Induced Lightning OvervoltageInduced lightning overvoltage refers to the transient overvoltage generated on overhead distribution lines due to nearby lightning discharges, even when the line is not directly struck. When a lightning flash occurs in the vicinity, it induces a large amount of charge on the conductors—opposite in polarity to the charge in the thundercloud.Statistical data shows that lightning-related faults caused by induced overvoltages account for approximately 90% of total fau
Echo
11/03/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.