Power Distribution Systems

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Electrical Power Distribution System Definition


An electrical power distribution system is defined as a network that delivers power to individual consumer premises at a lower voltage level.

 


An electrical power distribution system provides power to individual consumer premises. The distribution of electric power to different consumers is transmitted via a much lower voltage level compared to the transmission of power over long distances (i.e. over long transmission lines).

 


The distribution of electric power is done through distribution networks. Distribution networks consist of the following parts:

 


  • Distribution substation

  • Primary distribution feeder

  • Distribution Transformer

  • Distributors

  • Service mains


The transmitted electric power is stepped down in substations, for primary for distribution purposes.

 


This stepped down electric power is fed to the distribution transformer through primary distribution feeders. Overhead primary distribution feeders are supported by mainly supporting iron poles (preferably rail poles).

 


The conductors are strand aluminum conductors and they are mounted on the arms of the pole by means of pin insulators. Sometimes in congested places, underground cables may also be used for primary distribution purposes.

 


c5f33c69d64788239f694d6f460a1b08.jpeg

 


Distribution transformers are mainly 3 phase pole mounted type. The secondary of the transformer is connected to distributors. Different consumers are fed electric power by means of the service mains.

 


These service mains are tapped from different points of distributors. The distributors can also be re-categorized by distributors and sub-distributors. Distributors are directly connected to the secondary distribution transformers whereas sub-distributors are tapped from distributors.

 


Service mains of the consumers may be either connected to the distributors or sub-distributors depending upon the position and agreement of consumers.

 


In power distribution, both feeders and distributors carry electrical loads, but feeders carry power without intermediate taps, while distributors have multiple tap points to serve consumers.

 


The feeder feeds power from one point to another without being tapped from any intermediate point. As there is no tapping point (i.e. a point where the voltage and current can be stepped down or stepped up) in between, the current at the sending end is equal to that of the receiving-end of the conductor.

 


The distributors are tapped at different points for feeding different consumers, and hence the current varies along their entire length.

 


Components of Distribution Networks


Distribution networks consist of distribution substations, primary distribution feeders, distribution transformers, distributors, and service mains.

 


Radial Power Distribution System


This system has feeders radiating from a substation but can cause power interruptions if a feeder fails.

 


c5f33c69d64788239f694d6f460a1b08.jpeg

 


In the early days of the electrical power distribution system, different feeders radially came out from the substation and connected to the primary distribution transformer.

 


But radial electrical power distribution system has one major drawback that in case of any feeder failure, the associated consumers would not get any power as there was no alternative path to feed the transformer.

 


In the case of a transformer failure, the power supply is interrupted. In other words, the consumer in the radial electrical distribution system would be in darkness until the feeder or transformer was rectified.

 


Ring Main Power Distribution System


A ring main distribution system uses a ring network of distributors fed by multiple feeders, providing continuous power supply even if one feeder fails.

 


00868475eb1520a9172e8b35b8b3f0e9.jpeg

 

 

 

Section Isolators


These devices in ring main systems isolate parts of the network for maintenance or faults, maintaining power supply to other parts.


Give a tip and encourage the author!
Recommended
What are the safety precautions and guidelines for using AC load banks?
What are the safety precautions and guidelines for using AC load banks?
AC load banks are electrical devices used to simulate real-world loads and are widely applied in power systems, communication systems, automation control systems, and other fields. To ensure personal and equipment safety during use, the following safety precautions and guidelines must be observed:Select an appropriate AC load bank: Choose an AC load bank that meets actual requirements, ensuring its capacity, voltage rating, and other parameters satisfy the intended application. Additionally, sel
Echo
11/06/2025
What should be noted when installing a Type K thermocouple?
What should be noted when installing a Type K thermocouple?
Installation precautions for Type K thermocouples are critical to ensuring measurement accuracy and extending service life. Below is an introduction to the installation guidelines for Type K thermocouples, compiled from highly authoritative sources:1.Selection and Inspection Select the appropriate thermocouple type: Choose the right thermocouple based on the temperature range, medium properties, and required accuracy of the measurement environment. Type K thermocouples are suitable for temperatu
James
11/06/2025
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.