Me ke so kuɗi da Tap Changer a Zama da Ba Zama?

Encyclopedia
فیلڈ: Dakilin ƙasashen ilimi
0
China

Me kwa ce On Load da No Load Tap Changer?

Takaitaccen

On-load tap-changer da no-load tap-changer na transformer suna da alaka don rarraba hanyar zama na transformer.

4448842fafa081a55a73e9e27ad3704f.jpeg

Load Tap Changer (LTC)

Farkon

  • Gin tap position under load: Tap position yana iya canzawa idan transformer tana da muhimmanci bane da shiga cikin power supply.

  • Adjust the output voltage: Adjust the output voltage by changing the transformer ratio to adapt to different load requirements.

Peculiarity

  • Flexible operation:tap position yana iya canzawa bane da shiga cikin power failure.

  • Automatic or manual control: Automatic or manual adjustment can be achieved to adapt to different application scenarios.

  • Wide adjustment range: there are usually more tap positions to provide finer voltage regulation capabilities.

  • High complexity: The structure is relatively complex and requires more maintenance.

Application scenario

  • Power system: Widely used in power transmission and distribution networks to adapt to different load changes.

  • Industrial sector: Used in factories and large facilities to ensure a stable voltage supply.

No-Load Tap Changer (NLTC)

Farkon

  • Change tap position when not under load: Tap position yana iya canzawa idan transformer ba tana da muhimmanci bane da shiga cikin power supply.

  • Adjust the output voltage: Adjust the output voltage by changing the transformer ratio, but it needs to be carried out under no-load conditions.

Peculiarity

  • Simple structure: Compared with on-load tap-changer, the structure is simpler and the maintenance cost is lower.

  • Easy operation: Usually manually operated by simple mechanical or electric means.

  • Limited adjustment range: Few tap positions are provided and the adjustment range is relatively narrow.

Application scenario

  • Small transformers: Suitable for small transformers or applications that do not require frequent adjustment of tap positions.

  • Specific applications: In situations where frequent voltage regulation is not required, or in cost-sensitive applications.

Maintenance and inspection

  • Regular inspection: Whether the tap-changer is loaded or unloaded, it needs regular inspection and maintenance to ensure that it works properly.

  • Lubrication: Regularly lubricate the moving parts of the tap-changer to reduce wear.

  • Clean: Remove dust and dirt around the tap-changer to avoid affecting operation.

  • Electrical check: Check the electrical connection of the tap-changer to ensure good contact.

Matters needing attention

  • Safe operation: When maintaining or adjusting the tap position, observe the safe operation rules.

  • Environmental adaptability: Select the tap changer that is suitable for local environmental conditions.

Conclusion

By using on-load tap-changer and no-load tap-changer, the output voltage of the transformer can be adjusted according to actual needs, so as to ensure the stability and reliability of the power supply system.