Fault of Electric Cable

Electrical4u
Electrical4u
Field: Basic Electrical
0
China

Electric Cable Faults

It can be of three (3) types of electric cable faults found. They are

  • There may be a short circuit between two conductors,

  • There may be earth fault, i.e., fault between conductor and ground,

  • There may be open circuit caused due to disconnection of the conductor.

There can be more than one of the faults at a time.
The primary cause of the 1st and 2nd fault is due to damage of insulation caused by water, moisture or other reason. Due to the defect in the armour, plumbing or the lubricant compound gets out due to excess heat, insulation of the cable can get damaged.

Moreover, due to ageing, the insulation can get damaged. Normally the lifespan of a cable is about 40 to 50 years. PVC cable gets damaged due to wrong handling. If the compound elements decrease in the terminal box, the fault in cable occurs. If we do not join or terminate the cable properly, there may be an open circuit fault. Due to depression in the soil, there can be a stretch in the joint which may lead to an open circuit fault. Moreover, if we do not fit the clamps properly below the terminal box, an open circuit fault may occur. Apart from these, all reasons for the short circuit may also lead to an open circuit fault.fault of electric cable

Detection of Fault in Cable

If there is any fault in the cable, through megger test, it is to be detected that, what types of the fault have occurred. If required the fault resistance should get measured by multimeter. After the fault is detected, one should first examine the entire terminal box. In most of the occasion, you will see that the fault is in the terminal box. If there is indoor and outdoor box in the cable, then we check the outdoor box first, then the indoor box. If we do not find any fault in the terminal box, then we have to locate the place where the cable got a fault. If there is joint in the cable one should inspect the same, too.

If fault resistance is found more then where the fault occurs, one should burn the insulation “Fault Burning” and can decrease the resistance and after that Murray Loop Test can be done. Normally V.C. high voltage pressure testing set is used in fault burning work. If there is faults in more than one core then the core which is having less resistance that is to be burnt. The burning depends upon the fault and conditions of the cable. Normally the rate of resistance comes down within 15 to 20 minute.

If there is a fault in the cable, we should detect the type of fault with a megger. We normally measure earth resistance of each core. If there is a short between the core and the earth, the I.R. of such core will show ‘ZERO” or very less in megger meter. If we do not find continuity in any core between two ends, there is an open circuit on such core. If there is no continuity in all the three cores, we can understand that the entire three cores are open circuited.
After detecting the fault, we have to repair the cable.

Localisation of Cable Fault

There are different methods to detect the location of the fault in the cable. We adopt different methods in different situations. Some of the methods are herein below:

  • Murray Loop Test

  • Voltage Drop Test.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
What should be noted when installing a Type K thermocouple?
What should be noted when installing a Type K thermocouple?
Installation precautions for Type K thermocouples are critical to ensuring measurement accuracy and extending service life. Below is an introduction to the installation guidelines for Type K thermocouples, compiled from highly authoritative sources:1.Selection and Inspection Select the appropriate thermocouple type: Choose the right thermocouple based on the temperature range, medium properties, and required accuracy of the measurement environment. Type K thermocouples are suitable for temperatu
James
11/06/2025
Essential Rules for 3-Level Electrical Distribution
Essential Rules for 3-Level Electrical Distribution
Essential Rules for Three-Level Power Distribution System Design1.Hierarchical and Branch Circuit Distribution(1) Power distribution from the primary main distribution board (distribution cabinet) to secondary distribution boards can be branched; that is, one main distribution board may supply power via multiple branch circuits to several secondary distribution boards.(2) Similarly, power distribution from a secondary distribution board to tertiary switch boxes can also be branched; that is, one
Dyson
11/06/2025
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
What are the technical measures for loss reduction and energy saving in distribution systems?
What are the technical measures for loss reduction and energy saving in distribution systems?
1.Reasonable Use of TransformersTransformers should be selected with flexible winding configurations according to the power consumption characteristics of industrial enterprises, and load adjustments should be made promptly based on each transformer’s load rate to ensure operation at optimal loading conditions. Three-phase loads on transformers should be kept as balanced as possible; unbalanced operation not only reduces output capacity but also increases losses. Energy-efficient transformers sh