What is Induction Motor Maintenance ?

Encyclopedia
08/14/2024

What is Induction Motor Maintenance ?

Induction motor maintenance definition

Induction motor maintenance involves operations that increase the life of the equipment and help it operate more efficiently.

Maintenance types of induction motors

Squirrel cage induction motors: Squirrel cage induction motors require much less maintenance because they do not contain brushes, commutators, or slip rings.

d7fb8bbdcea54e1ff655e90058c9b829.jpeg

Coil rotor induction motor: Because it contains slip rings, brushes, so it does need to be maintained from time to time.

f8551b8ba6bf28d7ee10f1e910f3f438.jpeg

Maintenance type

Maintenance is divided into restorative (corrective)

This type of maintenance occurs after a failure occurs. It has the disadvantages of shortening the service life of the machine and wasting energy. It is also known as corrective maintenance.

Protective (preventive) type

This relates to planned measures taken to prevent breakdowns and failures. Examples include oil changes, lubrication, belt tightening, and filter changes.

Common fault

  • Stator winding fault

  • Bearing failure

  • Rotor fault

Maintenance schedule

Regular maintenance tasks should be performed weekly, every five/six months, and once a year to keep the motor in good condition.

Importance of maintenance

A proper maintenance schedule is essential to prevent costly repairs and ensure efficient operation, especially for three-phase induction motors.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

What are the common faults of low-voltage voltage transformers?
What are the common faults of low-voltage voltage transformers?
Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In low
Felix Spark
07/18/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
Fault Analysis of Single - Phase Grounding of Three - Phase 4PT Voltage Transformer
Fault Analysis of Single - Phase Grounding of Three - Phase 4PT Voltage Transformer
In 10 kV and 35 kV ungrounded systems, single - phase grounding faults cause minimal current, so protection rarely trips. Per regulations, operation is limited to 2 hours; prolonged undetected faults may worsen, even damaging switches. While the State Grid promotes small - current grounding line selection devices in 110 kV and 220 kV substations, their accuracy remains low, requiring monitoring/operation staff to analyze remote measurements. For ungrounded systems with three - phase 4PT voltage
Felix Spark
07/15/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!