Types of DC Generators

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

DC Generator Types

  • Permanent Magnet DC Generators – Field coils excited by permanent magnets

  • Separately Excited DC Generators – Field coils excited by some external source

  • Self Excited DC Generators – Field coils excited by the generator itself

Self Excited Generator

A self-excited DC generator uses its own output to power its field coils, which can be arranged as series, shunt, or compound wound.

The three types of self-excited DC generators are:

  • Series Wound Generators

  • Shunt Wound Generators

  • Compound Wound Generators

Permanent Magnet DC Generator 

6603018d254a670a9cb26bd227951ed0.jpeg

When the flux in the magnetic circuit is created through the use of permanent magnets, then it is known as a Permanent magnet DC generator.

It consists of an armature and one or several permanent magnets situated around the armature. This type of DC generator generates does not generate much power. As such they are rarely found in industrial applications. They are normally used in small applications – like dynamos in motorcycles.

Separately Excited DC Generator

These are the generators whose field magnets are energized by some external DC source, such as a battery.

A circuit diagram of separately excited DC generator is shown in the figure below. The symbols below are:

Ia = Armature current

IL = Load current

V = Terminal voltage

Eg = Generated EMF (Electromagnetic Force)

26291990af8f81bb5700184a03ca2dac.jpeg

f17814eccc1af386a923be8c944a5dc7.jpeg

Self Excited DC Generators

Self Excited DC Generators: These generators energize their own field magnets using the current they generate. The field coils in these machines are directly connected to the armature.

Due to residual magnetism, some flux is always present in the poles. When the armature is rotated, some EMF is induced. Hence some induced current is produced. This small current flows through the field coil as well as the load and thereby strengthening the pole flux.

As the pole flux strengthened, it will produce more armature EMF, which cause the further increase of current through the field. This increased field current further raises armature EMF, and this cumulative phenomenon continues until the excitation reaches the rated value.

According to the position of the field coils,self-excited DC generators may be classified as:

  • Series Wound Generators

  • Shunt Wound Generators

  • Compound Wound Generators

Series Wound Generator

In this configuration, the field windings are connected in series with the armature conductors, enhancing the flow of electricity throughout the generator.

Whole current flows through the field coils as well as the load. As series field winding carries full load current it is designed with relatively few turns of thick wire. The electrical resistance of series field winding is therefore very low (nearly 0.5Ω ).

Here:

Rsc = Series winding resistance

Isc = Current flowing through the series field

Ra = Armature resistance

Ia = Armature current

IL = Load current

V = Terminal voltage

Eg = Generated EMF

eab79b1a5d6a94e74dbdc6d5989bbe90.jpeg

3410d9cb2783632a4c83f83574f70f4c.jpeg

Long Shunt Compound Wound DC Generator

Long Shunt Compound Wound DC Generator are generators where the shunt field winding is in parallel with both series field and armature winding, as shown in the figure below.

ab35273983549b44658a188c120c0b96.jpeg

 

f6a65a7bfa0d322307e4d4dcb93cf506.jpeg

Compound Wound Dynamics

 In these generators, the predominant shunt field is supported by the series field, leading to what is known as a cumulative compound configuration.

dfd0d702654b804cea0d7b59c5045683.jpeg

 On the other hand, if the series field opposes the shunt field, the generator is said to be differentially compound wound.

Give a tip and encourage the author!
Recommended
How to Choose & Maintain Electric Motors: 6 Key Steps
How to Choose & Maintain Electric Motors: 6 Key Steps
"Selecting a High-Quality Motor" – Remember the Six Key Steps Inspect (Look): Check the motor’s appearanceThe motor’s surface should have a smooth, even paint finish. The nameplate must be properly installed with complete and clear markings, including: model number, serial number, rated power, rated current, rated voltage, allowable temperature rise, connection method, speed, noise level, frequency, protection rating, weight, standard code, duty type, insulation class, manufacturing date, and ma
Felix Spark
10/21/2025
 What Is the Working Principle of a Power Plant Boiler?
What Is the Working Principle of a Power Plant Boiler?
The working principle of a power plant boiler is to utilize the thermal energy released from fuel combustion to heat feedwater, producing a sufficient quantity of superheated steam that meets specified parameters and quality requirements. The amount of steam produced is known as the boiler's evaporation capacity, typically measured in tons per hour (t/h). Steam parameters primarily refer to pressure and temperature, expressed in megapascals (MPa) and degrees Celsius (°C), respectively. Steam qua
Edwiin
10/10/2025
What is the principle of live-line washing for substations?
What is the principle of live-line washing for substations?
Why Do Electrical Equipment Need a "Bath"?Due to atmospheric pollution, contaminants accumulate on insulating porcelain insulators and posts. During rain, this can lead to pollution flashover, which in severe cases may cause insulation breakdown, resulting in short circuits or grounding faults. Therefore, the insulating parts of substation equipment must be periodically washed with water to prevent flashover and avoid insulation degradation that could lead to equipment failure.Which Equipment Is
Encyclopedia
10/10/2025
Essential Dry-Type Transformer Maintenance Steps
Essential Dry-Type Transformer Maintenance Steps
Routine Maintenance and Care of Dry-Type Power TransformersDue to their flame-resistant and self-extinguishing properties, high mechanical strength, and ability to withstand large short-circuit currents, dry-type transformers are easy to operate and maintain. However, under poor ventilation conditions, their heat dissipation performance is inferior to that of oil-immersed transformers. Therefore, the key focus in the operation and maintenance of dry-type transformers is controlling the temperatu
Noah
10/09/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.