Failure Analysis of Electric Vehicle AC Charging Piles

Felix Spark
06/23/2025

As new energy electric vehicles become increasingly popular, the number of supporting public charging piles is growing year by year. Whether the measurement value of AC charging piles for electric vehicles is accurate is directly related to the vital interests of the vast number of electric vehicle owners. So, conducting regular mandatory inspections of charging piles is particularly important. Below, combined with relevant regulations and practical work, I’ll share some experience and practices on properly carrying out verification, fault analysis, repair, and correct maintenance of AC charging piles for electric vehicles.
1 Common Faults of AC Charging Piles for Electric Vehicles
During the use of AC charging piles, the main circuit is directly affected by current and voltage stress, which is the main cause of faults in AC charging piles. In terms of fault states, there are mainly two common situations for charging piles.
1.1 The power indicator of the charging pile is not on and it can’t charge
1.1.1 Fault Causes
A possible fault cause is that the charging power connection is abnormal:

The AC charging connection device is not properly connected; there is a fault in the charging pile circuit.

1.1.2 Fault Diagnosis & Troubleshooting
Diagnosis flow as Figure 1.
  • Check distribution cabinet main switch (closed in normal operation; close if open).
  • Test main switch output voltage (L - N, L - PE should be 220V). Abnormal voltage → check/reconnect circuit or replace switch (open, loose, damaged).
  • Test charging pile input voltage (L - N, L - PE should be 220V). Abnormal voltage → reconnect circuit or replace switch (open/damaged).
1.2 Physical Connection Done, Charging Started but No Charge
Occurs when power, plug - battery connection, and standby state are normal. 7 cases:
  • Normal charge but monitoring data shows 0 → Communication fault between pile & system.
    Fix: ① Restart monitoring/server; ② Reboot pile display; ③ Power - cycle display system & program.
  • Charge current <20A (normal state) → Display/program fault.
    Fix: ① Restart display program; ② Power - cycle pile & program; ③ Reinstall display/program.
  • Can’t charge/enter interface → Communication fault.
    Fix: ① Check display parameters; ② Power - cycle display system/program; ③ Reinstall display/program.
  • No BMS communication after display reboot → Communication fault.
    Fix: ① Power - cycle display system/program; ② Reinstall display/program; ③ Replace CAN bus module 200T.
  • BMS normal, voltage normal but 0 current → Mistaken emergency stop press.
    Fix: ① Release emergency stop; ② Check battery & BMS.
  • BMS normal, no charge voltage → Mistaken emergency stop press.
    Fix: ① Release emergency stop; ② Check battery & BMS.
  • BMS normal, voltage fluctuates, 0 current → Charging module fault.
    Fix: Replace module.

2 Proper Use & Maintenance of EV Charging Piles

  • Pre - charge: Inspect equipment (cables, connectors) for damage.
  • Abnormality during use: Press emergency stop → cut all power.
  • Keep flammables/explosives (gases, chemicals) away.
  • Don’t use if gun/cable has defects (cracks, wear, exposed wires).
  • Never unplug during charging; no live - contact with gun core.
  • Avoid outdoor charging in rain/thunder. Prohibit charging if water nears vehicle height.
Felix Spark

Hey there! I'm an electrical engineer specializing in Failure and Maintenance. I've dedicated my career to ensuring the seamless operation of electrical systems. I excel at diagnosing complex electrical failures, from malfunctioning industrial motors to glitchy power distribution networks. Using state - of - the - art diagnostic tools and my in - depth knowledge, I pinpoint issues quickly. On this platform, I'm eager to share my insights, exchange ideas, and collaborate with fellow experts. Let's work together to enhance the reliability of electrical setups.

Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the common faults of low-voltage voltage transformers?
What are the common faults of low-voltage voltage transformers?
1. Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In lo
Oliver Watts
07/16/2025
Fault Analysis of Single - Phase Grounding of Three - Phase 4PT Voltage Transformer
Fault Analysis of Single - Phase Grounding of Three - Phase 4PT Voltage Transformer
In 10 kV and 35 kV ungrounded systems, single - phase grounding faults cause minimal current, so protection rarely trips. Per regulations, operation is limited to 2 hours; prolonged undetected faults may worsen, even damaging switches. While the State Grid promotes small - current grounding line selection devices in 110 kV and 220 kV substations, their accuracy remains low, requiring monitoring/operation staff to analyze remote measurements. For ungrounded systems with three - phase 4PT voltage
Felix Spark
07/15/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!