What is Testing of Electrical Power Cable ?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

What is Testing of Electrical Power Cable ?


Type Tests Definition


Type tests ensure the quality and standards of electrical power cables by assessing various physical and electrical properties.


Acceptance Tests


Acceptance tests verify that a batch of cables meets the required specifications through mechanical and electrical tests.


Routine Tests


Routine tests are regular checks to maintain consistent quality and performance of electrical cables.


High Voltage Test (Water Immersion Test)


A 3-meter-long core sample is taken from the finished cable or cord. The sample is immersed in a water bath at room temperature, with the ends protruding at least 200 mm above the water. After 24 hours, an alternating voltage is applied between the conductor and the water. The voltage is increased within 10 seconds and held constant for 5 minutes. If the sample fails, another sample is tested.


Test on completed cables (Acceptance and routine test)


These tests are conducted between conductors or between conductor and screen/armor. They are performed at the required voltage, at room temperature, and for a duration of 5 minutes, ensuring no insulation failure.


Flammability Test


Period of burning after removal of the flame shall not exceed 60 sec and the unaffected portion from the lower edge of the top clamp shall be at least 50 mm.


Cable Testing Importance


Cable testing is crucial for ensuring the safety, reliability, and longevity of electrical power systems.

 


Give a tip and encourage the author!
Recommended
Three-Phase SPD: Types, Wiring & Maintenance Guide
Three-Phase SPD: Types, Wiring & Maintenance Guide
1. What Is a Three-Phase Power Surge Protective Device (SPD)?A three-phase power surge protective device (SPD), also known as a three-phase lightning arrester, is specifically designed for three-phase AC power systems. Its primary function is to limit transient overvoltages caused by lightning strikes or switching operations in the power grid, thereby protecting downstream electrical equipment from damage. The SPD operates based on energy absorption and dissipation: when an overvoltage event occ
James
12/02/2025
Railway 10kV Power Through Lines: Design & Operation Requirements
Railway 10kV Power Through Lines: Design & Operation Requirements
The Daquan Line has a large power load, with numerous and scattered load points along the section. Each load point has a small capacity, with an average of one load point every 2-3 km, so two 10 kV power through lines should be adopted for power supply. High-speed railways use two lines for power supply: primary through line and comprehensive through line. The power sources of the two through lines are taken from the dedicated bus sections fed by the voltage regulators installed in each power di
Edwiin
11/26/2025
Neutral Grounding Methods for Conventional-Speed Railway Power Systems
Neutral Grounding Methods for Conventional-Speed Railway Power Systems
Railway power systems primarily consist of automatic block signaling lines, through-feeder power lines, railway substations and distribution stations, and incoming power supply lines. They provide electricity to critical railway operations—including signaling, communications, rolling stock systems, station passenger handling, and maintenance facilities. As an integral part of the national power grid, railway power systems exhibit distinct characteristics of both electrical power engineering and
Echo
11/26/2025
Application of Condition Monitoring Technology in UHV Transmission Lines
Application of Condition Monitoring Technology in UHV Transmission Lines
1. Application of Condition Monitoring Technology in UHV Transmission LinesAt present, the main characteristics of UHV (Ultra-High Voltage) transmission line condition monitoring technology in China are reflected in the following aspects: Comprehensiveness: In general, during the implementation of monitoring technology, supporting facilities and integrated systems are required to ensure effective monitoring performance; High value: UHV transmission line condition monitoring technology is a criti
Echo
11/20/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.