What is Energy Meter Testing?

Encyclopedia
Field: Encyclopedia
0
China

What is Energy Meter Testing?



Energy Meter Definition


An energy meter is defined as a device that measures the electrical energy consumption in various settings like homes and industries.


Standard Tests for Energy Meters


Performance tests for energy meters, according to IEC standards, are divided into three main segments: mechanical aspects, electrical circuits, and climatic conditions.


Mechanical component tests.


Climatic conditions test include those limits which influence the performance of the meter externally.Electrical requirements covered many tests before giving accuracy certificate.


Electromagnetic Compatibility Test


The electromagnetic compatibility (EMC) test is crucial for ensuring the accuracy of an energy meter. This test is divided into two parts: Emission tests and Immunity tests. Today, electromagnetic interference (EMI) is a common issue.


Those circuits in use today, can emit electromagnetic energy which can affect the performance and reliability of both its inner circuitry and the nearby equipment. EMI can travel through conduction or by radiation. When EMI goes through the wire or through cables, it is called conduction. When it travels through free space, it is called radiation.


Emission Test


In an electronic system, there are many components like switching elements, chokes, circuit layout, rectifying diodes and much more which produce EMI. This test ensures that the energy meter does not affect the performance of the nearby instruments or we can say that it ensures that it does not conduct or radiate EMI beyond a definite limit. There are two types of emission test based on the EMI escapes from the system.


Conducted emission test


In this test, power lead and cables are checked to measure the EMI escape, and it covers small meter of the frequency range from 150 kHz to 30 MHz.


Radiated emission test


This test measures the EMI escape through free space, and it covers large meters of the frequency range from 31 MHz to 1000MHz.


Immunity Test


The emission test makes sure the meter does not emit EMI that affects nearby equipment. The immunity test ensures the meter functions well even when there is EMI around it. There are two types of immunity tests: one based on radiation and the other on conduction.


Conducted immunity test


These tests ensure the meter functions properly even when surrounded by EMI. The EMI source can be through data lines, interface lines, power lines, or direct contact.


Radiated immunity test


During this test, meter functioning is monitored and if it gets affected by EMI present in the surrounding area, that fault is recognized and corrected their only. It also is known as the electromagnetic high-frequency field test. Radiations generated by sources like small handheld radio transceivers, transmitters, switches, welders, fluorescent lights, switches, operating inductive loads etc.

Give a tip and encourage the author!

Recommended

Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Reclosing Charge Time: Why Does Reclosing Require Charging? What Effects Does Charging Time Have?
1. Function and Significance of Reclosing ChargingReclosing is a protective measure in power systems. After faults such as short circuits or circuit overloads occur, the system isolates the faulty circuit and then restores normal operation through reclosing. The function of reclosing is to ensure continuous operation of the power system, improving its reliability and safety.Before performing reclosing, the circuit breaker must be charged. For high-voltage circuit breakers, the charging time is g
12/15/2025
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.