Whether AC circuit breaker can be used for DC circuit ?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

AC circuit breakers (AC circuit breakers) are mainly used to protect devices in AC circuits from overload, short circuit, or ground faults. However, if an AC circuit breaker is to be used in a direct current circuit (DC circuit), several key factors need to be considered:


Type of circuit breaker


  •   AC circuit breaker (AC) : Circuit breakers designed for AC power rely on the natural zero crossing of AC power when cutting off current. Alternating current has two zero crossing points in each cycle, which helps to break the arc and extinguish the arc.


  • Direct current circuit breaker (DC) : There is no natural zero crossing of direct current, so the circuit breaker must be able to cut off the current at any point in time, and special arc extinguishing technology is required to prevent the continuous burning of the arc.


Arc breaking capacity


  • Ac circuit: When the AC circuit breaker cuts off the current, the arc will be naturally extinguished at each zero crossing, which helps the circuit breaker cut off the current.



  • Direct current circuit: DC circuit breakers need to be designed with a special arc extinguishing mechanism, because there is no natural zero crossing in direct current, the arc is not easy to be extinguished, which may lead to equipment damage.


Design variance


  • Arc extinguishing technology: AC circuit breakers usually use simple arc extinguishing technology, such as magnetic blowout or air blast.



  •   Dc circuit breakers: More sophisticated interrupter techniques may be required, such as a vacuum interrupter, SF6 gas (sulfur hexafluoride) interrupter, or other interrupter techniques specifically designed for direct current.


Operating characteristics


  • Current waveform: AC circuit breakers are designed to take into account the waveform of alternating current, while DC circuit breakers take into account the characteristics of direct current.



  • Time-current characteristics (TCC) : The time-current characteristics of AC circuit breakers may not be suitable for the requirements of direct current circuits.


Specifications and standards


  • Ratings: AC circuit breakers and DC circuit breakers have different ratings, including rated current, rated voltage, and breaking capacity.



  • Standards: AC circuit breakers and DC circuit breakers comply with different international or national standards, such as IEC, UL, etc.


Application scenario


  • Ac circuit: AC circuit breaker is suitable for household appliances, industrial motors, lighting systems and other AC circuits.



  • Direct current circuit: DC circuit breaker is suitable for solar system, electric vehicle, communication equipment, data center and other direct current circuit.


Feasibility


In principle, AC circuit breakers are not recommended for direct current circuits, because their design and working principle do not match the characteristics of direct current. Using AC circuit breakers to protect the DC circuit may cause the following problems:


  • Failure to extinguish arc: The current cannot be effectively cut off, resulting in persistent arc.



  • Equipment damage: Failure to turn off the current properly may result in overheating or damage to the equipment.



  • Safety risk: Increased risk of fire and electric shock.


Suggestion


For direct current circuits, it is recommended to use a circuit breaker specifically designed for direct current (DC circuit breaker) to ensure the safe and reliable operation of the equipment.


Sum up


Ac circuit breakers are usually not suitable for direct current circuits because their design and working principle do not match the characteristics of direct current. If you need to use a circuit breaker in a direct current circuit, choose a circuit breaker designed for direct current.


Give a tip and encourage the author!
Recommended
300MW+ Unit Generator Circuit Breaker Automatic Tripping: Causes, Phenomena & Handling Measures
300MW+ Unit Generator Circuit Breaker Automatic Tripping: Causes, Phenomena & Handling Measures
Units with a capacity of 300MW and above are usually connected in a generator-transformer unit configuration and connected to the power system through the circuit breaker on the high-voltage side of the transformer. During the normal operation of the unit, the circuit breaker may trip automatically due to various reasons. Operators must make correct judgments and take timely measures to ensure the safe operation of the unit.1. Causes of Automatic Circuit Breaker Tripping Tripping due to relay pr
Felix Spark
11/27/2025
Chinese GCB makers developed complete sets for 1GW unit applications.
Chinese GCB makers developed complete sets for 1GW unit applications.
Recently, a Chinese generator circuit breaker manufacturer has successfully developed generator circuit breakers for 1,000MW hydropower and thermal power units, which have passed the group's appraisal and acceptance. Their comprehensive performance has reached the international leading level, filling the domestic gap. This is another major breakthrough following the group's mastery of the technology for large-capacity generator circuit breaker complete sets for 400MW, 600MW, and 800MW units, mar
Baker
11/26/2025
Latest Development Trends of SF6 Alternative Gas-Based High-Voltage Circuit Breakers
Latest Development Trends of SF6 Alternative Gas-Based High-Voltage Circuit Breakers
1. IntroductionSF₆ is widely used in electric power transmission and distribution systems, such as gas-insulated switchgear (GIS), circuit breakers (CB), and medium-voltage (MV) load switches. It possesses unique electrical insulation and arc-quenching capabilities. However, SF₆ is also a potent greenhouse gas, with a global warming potential of approximately 23,500 over a 100-year time horizon, and therefore its use is regulated and subject to ongoing discussions regarding restrictions. Consequ
Echo
11/21/2025
126(145)kV Vacuum Circuit Breaker Installation & Adjustment Guide
126(145)kV Vacuum Circuit Breaker Installation & Adjustment Guide
High-voltage vacuum circuit breakers, owing to their excellent arc-quenching characteristics, suitability for frequent operation, and long maintenance-free intervals, have been widely applied in China’s power industry—particularly in urban and rural power grid upgrades, as well as in chemical, metallurgical, railway electrification, and mining sectors—and have received widespread acclaim from users.The primary advantage of vacuum circuit breakers lies in the vacuum interrupter. However, the char
James
11/20/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.