What is Proximity Effect?

Edwiin
Edwiin
Field: Power switch
China

Definition: When conductors carry high alternating voltages, the currents are non - uniformly distributed across the cross - sectional area of the conductor. This phenomenon is known as the proximity effect. The proximity effect causes an increase in the apparent resistance of a conductor because of the presence of other current - carrying conductors in its vicinity.

When two or more conductors are positioned close to one another, their electromagnetic fields interact. As a result of this interaction, the current in each conductor is redistributed. Specifically, a higher current density accumulates in the part of the conductor strand that is furthest from the interfering conductor.

If the conductors carry current in the same direction, the magnetic fields of the adjacent halves of the conductors cancel each other out. Consequently, no current flows through these adjacent half - portions of the conductors, and the current instead crowds into the remote half - portions.

When conductors carry current in opposite directions, the magnetic fields in the closer portions of the conductors reinforce each other, leading to a higher current density in these adjacent regions. Conversely, the magnetic fields in the farther halves of the conductors cancel each other out, resulting in minimal or zero current flow in those remote areas. Consequently, the current becomes concentrated in the nearer parts of the conductors, while the far-off halves exhibit significantly reduced current.

If DC flows through a conductor, the current is uniformly distributed across the conductor's cross-sectional area. As a result, no proximity effect occurs on the conductor's surface.

The proximity effect is only significant for conductor sizes larger than 125 mm². To account for this, correction factors must be applied.

When accounting for the proximity effect, the AC resistance of the conductor becomes:

Notations:

  • Rdc: Uncorrected DC resistance of the conductor.

  • Ys: Skin effect factor (the fractional increase in resistance due to the skin effect).

  • Yp: Proximity effect factor (the fractional increase in resistance due to the proximity effect).

  • Re: Effective or corrected ohmic resistance of the conductor.

The DC resistance Rdc can be obtained from stranded conductor tables.

Factors Influencing the Proximity Effect

The proximity effect primarily depends on factors such as the conductor material, diameter, frequency, and structure. These factors are detailed below:

  • Frequency – The proximity effect intensifies as the frequency increases.

  • Diameter – Larger conductor diameters lead to a more pronounced proximity effect.

  • Structure – This effect is more significant in solid conductors compared to stranded conductors (e.g., ASCR). Stranded conductors have a smaller effective surface area than solid conductors, reducing current crowding.

  • Material – Conductors made of high-ferromagnetic materials exhibit a stronger proximity effect on their surfaces due to magnetic field interactions.

Methods to Mitigate the Proximity Effect

One effective way to reduce the proximity effect is by using ACSR (Aluminum Conductor Steel Reinforced conductors. In an ACSR conductor:

  • Steel is placed at the core to provide mechanical strength.

  • Aluminum strands surround the steel core, forming the outer conductive layer.

This design minimizes the surface area exposed to magnetic field interactions. As a result, current primarily flows through the outer aluminum layers, while the steel core carries little to no current. This configuration significantly reduces the proximity effect in the conductor.

Give a tip and encourage the author!
Recommended
Composition and Working Principle of Photovoltaic Power Generation Systems
Composition and Working Principle of Photovoltaic Power Generation Systems
Composition and Working Principle of Photovoltaic (PV) Power Generation SystemsA photovoltaic (PV) power generation system is primarily composed of PV modules, a controller, an inverter, batteries, and other accessories (batteries are not required for grid-connected systems). Based on whether it relies on the public power grid, PV systems are divided into off-grid and grid-connected types. Off-grid systems operate independently without relying on the utility grid. They are equipped with energy-s
Encyclopedia
10/09/2025
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(2)
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(2)
1. On a scorching sunny day, do damaged vulnerable components need to be replaced immediately?Immediate replacement is not recommended. If replacement is necessary, it is advisable to do so in the early morning or late afternoon. You should contact the power station’s operation and maintenance (O&M) personnel promptly, and have professional staff go to the site for replacement.2. To prevent photovoltaic (PV) modules from being hit by heavy objects, can wire mesh protective screens be install
Encyclopedia
09/06/2025
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(1)
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(1)
1. What are the common faults of distributed photovoltaic (PV) power generation systems? What typical problems may occur in various components of the system?Common faults include inverters failing to operate or start due to voltage not reaching the startup set value, and low power generation caused by issues with PV modules or inverters. Typical problems that may occur in system components are burnout of junction boxes and local burnout of PV modules.2. How to handle common faults of distributed
Leon
09/06/2025
Short Circuit vs. Overload: Understanding the Differences and How to Protect Your Power System
Short Circuit vs. Overload: Understanding the Differences and How to Protect Your Power System
One of the main differences between a short circuit and an overload is that a short circuit occurs due to a fault between conductors (line-to-line) or between a conductor and earth (line-to-ground), whereas an overload refers to a situation where equipment draws more current than its rated capacity from the power supply.Other key differences between the two are explained in the comparison chart below.The term "overload" typically refers to a condition in a circuit or connected device. A circuit
Edwiin
08/28/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.