Reluctance Torque

04/22/2025

Reluctance torque, also known as alignment torque, is a phenomenon experienced by ferromagnetic objects when placed within an external magnetic field. This torque acts to align the ferromagnetic object with the direction of the external magnetic field. When exposed to an external magnetic field, the ferromagnetic object generates an internal magnetic field in response. The interaction between this induced internal magnetic field and the external magnetic field gives rise to reluctance torque, compelling the object to reorient itself until it is optimally aligned with the external magnetic field lines. This alignment occurs as the system seeks to minimize the magnetic reluctance, which is a measure of the opposition to the establishment of a magnetic flux within the object.

image.png

The torque arises from the interaction between the two magnetic fields, causing the object to twist around an axis aligned with the magnetic field direction. This torque acts upon the object, compelling it to reposition itself in a way that minimizes the magnetic reluctance, thereby facilitating the smoothest possible path for the magnetic flux to flow.

This torque is also referred to as saliency torque, as its generation is directly attributed to the saliency characteristics of the machine. Saliency, which refers to the geometric and magnetic asymmetry within the machine, creates variations in magnetic reluctance that drive the production of this torque.

Reluctance motors rely fundamentally on reluctance torque for their operation. The motor's functionality hinges on the continuous interaction and realignment of magnetic fields, enabled by this torque, to produce rotational motion. The magnitude of the reluctance torque can be calculated using a specific formula, which takes into account various parameters such as the magnetic field strengths, machine geometry, and material properties, providing a quantitative measure crucial for the design, analysis, and optimization of reluctance - based electrical machines.

image.png

In the context of reluctance torque calculations, the following notations are used:

  • Trel represents the average value of the reluctance torque.

  • V denotes the applied voltage, which plays a crucial role in energizing the motor and influencing the magnetic field interactions.

  • f stands for the line frequency, determining the rate at which the magnetic fields change and thus impacting the torque generation process.

  • δrel is the torque angle, measured in electrical degrees. This angle indicates the phase difference between the stator and rotor magnetic fields and is a key factor in calculating the magnitude of the reluctance torque.

  • K is the motor constant, a parameter specific to the motor that encapsulates various design - related characteristics, such as the magnetic circuit geometry and material properties.

Reluctance torque is predominantly generated within reluctance motors. The fundamental principle behind its production in these motors lies in the variation of magnetic reluctance. As the rotor moves within the magnetic field of the stator, changes in the air - gap length and magnetic path geometry cause fluctuations in reluctance. These variations, in turn, give rise to the reluctance torque, which drives the motor's rotation.

The stability limit of reluctance motors, in relation to the torque angle, typically ranges from +δ/4to -δ/4. Operating within this angular range ensures the motor maintains stable operation, avoiding issues such as stalling or erratic behavior.

In terms of construction, the stator of a reluctance motor closely resembles that of a single - phase induction motor, featuring windings designed to create a rotating magnetic field. The rotor, on the other hand, is commonly of the squirrel - cage type. This simple yet effective rotor design, combined with the unique magnetic characteristics of the stator, enables the efficient generation and utilization of reluctance torque, making reluctance motors suitable for a variety of applications where cost - effectiveness and reliable operation are key requirements.



Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.

Difference Between Short Circuit & Overload
Difference Between Short Circuit & Overload
One of the main differences between a short circuit and an overload is that a short circuit occurs due to a fault between conductors (line-to-line) or between a conductor and earth (line-to-ground), whereas an overload refers to a situation where equipment draws more current than its rated capacity from the power supply.Other key differences between the two are explained in the comparison chart below.The term "overload" typically refers to a condition in a circuit or connected device. A circuit
08/28/2025
Difference Between Leading and Lagging Power Factor
Difference Between Leading and Lagging Power Factor
Leading and lagging power factors are two key concepts related to the power factor in AC electrical systems. The main difference lies in the phase relationship between current and voltage: in a leading power factor, the current leads the voltage, whereas in a lagging power factor, the current lags behind the voltage. This behavior depends on the nature of the load in the circuit.What is Power Factor?Power factor is a crucial, dimensionless parameter in AC electrical systems, applicable to both s
08/26/2025
Difference Between Electromagnet and Permanent Magnet
Difference Between Electromagnet and Permanent Magnet
Electromagnets vs. Permanent Magnets: Understanding the Key DifferencesElectromagnets and permanent magnets are the two primary types of materials that exhibit magnetic properties. While both generate magnetic fields, they differ fundamentally in how these fields are produced.An electromagnet generates a magnetic field only when an electric current flows through it. In contrast, a permanent magnet inherently produces its own persistent magnetic field once it has been magnetized, without requirin
08/26/2025
Interpretation of the “Five Mandatory Surveys” for On - site Investigation in the Operation and Maintenance Specialty
Interpretation of the “Five Mandatory Surveys” for On - site Investigation in the Operation and Maintenance Specialty
The power outage and work scopes must be clearly inspectedCollaborate with the site survey leader to confirm the equipment to be maintained and the work area involved. Consider requirements such as the use of special vehicles and large machinery, and safe distances from adjacent energized equipment. Verify on-site whether the proposed power outage scope is sufficient to meet the operational needs.On-site safety measures must be clearly inspectedCollaborate with the site survey leader to verify s
Vziman
08/14/2025
Inquiry
Download