Why is Zener breakdown voltage less than avalanche breakdown voltage?

Encyclopedia
10/07/2024

Zener breakdown voltage and avalanche breakdown voltage are two different breakdown mechanisms in semiconductor devices, especially diodes. The breakdown voltage caused by these two mechanisms is different, mainly because of their different physical mechanisms and occurrence conditions.


Zener breakdown


Zener breakdown occurs in a reverse-biased PN junction, and when the applied reverse voltage is high enough, the electric field strength in the PN junction is enough to make the electrons in the valence band get enough energy to transition to the conduction band to form an electron-hole pair. This process mainly occurs in thin layers of semiconductor materials, especially in PN junctions with high doping concentrations.


Features


  • Occurrence condition: In PN junction with high doping concentration, the electric field strength is strong, which is easy to lead to electronic transition.


  • Breakdown voltage: Usually occurs at lower voltage levels, between about 2.5V and 5.6V.


  • Temperature coefficient: Negative temperature coefficient, meaning that as the temperature increases, the breakdown voltage will decrease.



Avalanche breakdown


Avalanche breakdown also occurs in reverse-biased PN junctions, but it is a collisional ionization process. When the applied reverse voltage reaches a certain value, the strong electric field accelerates the free electrons to a high enough kinetic energy to collide with the atoms in the lattice, creating new electron-hole pairs. These newly created electron-hole pairs continue to collide, forming a chain reaction that eventually leads to a sharp increase in current.


Features


  • Occurrence condition: In PN junction with low doping concentration, the electric field strength is weak, and higher voltage is required to trigger avalanche effect.


  • Breakdown voltage: Usually occurs at a high voltage level, about 5V or more, depending on the material and doping concentration.


  • Temperature coefficient: Positive temperature coefficient, meaning that as the temperature increases, the breakdown voltage will increase.



The main reasons why Zener breakdown voltage is less than avalanche breakdown voltage are as follows:


  • Doping concentration: Zener breakdown usually occurs in PN junctions with high doping concentrations, while avalanche breakdown occurs in PN junctions with low doping concentrations. The high doping concentration means that enough electric field strength can be achieved at a low applied voltage, so that the electrons in the valence band get enough energy to transition to the conduction band. In contrast, PN junctions with low doping concentrations require higher applied voltages to achieve the same electric field strength.


  • Electric field strength: Zener breakdown relies mainly on electron transitions caused by local strong electric fields, while avalanche breakdown relies on electric field strengths distributed uniformly over the entire PN junction region. Therefore, avalanche breakdown requires a higher voltage to create a sufficient impact ionization effect.


  • Material properties: Zener breakdown mainly occurs in some specific materials (such as silicon) and is related to the energy gap of the material. Avalanche breakdown depends more on the physical properties of the material, such as band gap width and carrier mobility.



Sum up


Zener breakdown and avalanche breakdown are two different breakdown mechanisms that occur under different conditions and have different temperature coefficients. Zener breakdown voltage is usually lower than avalanche breakdown voltage, this is because Zener breakdown occurs in high doping concentration of PN junction, while avalanche breakdown occurs in low doping concentration of PN junction, the former requires a low applied voltage to achieve sufficient electric field strength, the latter requires a high voltage to form the impact ionization effect.


Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
Load Frequency Control (LFC) & Turbine Governor Control (TGC) in Power System
Load Frequency Control (LFC) & Turbine Governor Control (TGC) in Power System
Brief Introduction to Thermal Generating UnitsElectricity generation relies on both renewable and non - renewable energy resources. Thermal generating units represent a conventional approach to power production. In these units, fuels such as coal, nuclear energy, natural gas, biofuel, and biogas are combusted within a boiler.The boiler of a generating unit is an extremely complex system. In its simplest conception, it can be visualized as a chamber whose walls are lined with pipes, through which
Edwiin
06/06/2025
Why 3-Phase Power? Why Not 6, 12 or More for Power Transmission?
Why 3-Phase Power? Why Not 6, 12 or More for Power Transmission?
It is well-known that single-phase and three-phase systems are the most prevalent configurations for power transmission, distribution, and end-use applications. While both serve as fundamental power supply frameworks, three-phase systems offer distinct advantages over their single-phase counterparts.Notably, multi-phase systems (such as 6-phase, 12-phase, etc.) find specific applications in power electronics—particularly in rectifier circuits and variable frequency drives (VFDs)—wher
Edwiin
06/05/2025
How Many Poles and Towers are Situated Within a 1-km Span?
How Many Poles and Towers are Situated Within a 1-km Span?
The number of distribution poles and transmission towers within a 1-kilometer stretch of overhead lines varies significantly based on multiple factors, including voltage level, power line type, supporting structure, geographical location, local regulations, and specific grid requirements.In urban areas, distribution utility poles are typically positioned at closer intervals, while in rural regions, they are spaced farther apart. Additionally, the use of taller structures for higher-voltage trans
Edwiin
06/05/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!