Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
10(6)/0.4kV Substation Layout Scheme(with workshop)
10(6)/0.4kV Substation Layout Scheme(with workshop)(a)Workshop built-in type(b)Workshop built-in type(c)Workshop built-out type(d)Workshop built-out type1-Transformer room2-Low voltage switchboard room3-Highvoltage switchboard room
Consult
Tip
Consult
Tip
10(6)/0.4kV Substation Layout Scheme
10(6)/0.4kV Substation Layout Scheme(a)Oil-immersed transformer substation(b)Dry transformer substation1-Overhead incoming line2-high-tension switch cabinet3-10(6)/0.4kVOil-immersed transformer4-Low voltage distributor5-10(6)/0.4kVDry transformer
Consult
Tip
Consult
Tip
35/10kV Substation Layout Scheme (One deck)
Substation Layout Scheme (One deck)1-Overhead incoming line2-Main transformer 4000kV3-Switch cabinet4-Switch cabine
Consult
Tip
Consult
Tip
35/10kV Substation Layout Scheme (Double deck)
Substation Layout Scheme (Double deck)a:floor 2b:floor 11-35kV Overhead entry line2-Main transformer 6300kV3-Switch cabinet4-Switch cabine
Consult
Tip
Consult
Tip
Standby redundant UPS
Standby redundant UPSnote:Input terminals can be connected together
Consult
Tip
Consult
Tip
UPS parallel connection with by-pass
UPS parallel connection with by-passnote:Input terminals can be connected together
Consult
Tip
Consult
Tip
UPS Partial parallel connection
UPS Partial parallel connection
Consult
Tip
Consult
Tip
UPS parallel connection
UPS parallel connectionnote:Input terminals can be connected together
Consult
Tip
Consult
Tip
The UPS runs in passive backup mode
The UPS runs in passive backup mode
Consult
Tip
Consult
Tip
Interactive operation of the UPS with bypass
Interactive operation of the UPS with bypass
Consult
Tip
Consult
Tip