Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
High Voltage Gas Insulted Switchgear (GIS) Field Testing According to IEEE C37.122
High Voltage Gas Insulted Switchgear (GIS) Field Testing According to IEEE C37.122The final assembly of the gas - insulated substation (GIS) takes place in the field. This is where all the diverse components that make up the GIS are brought together for the first time. Even if it were possible to fully assemble the GIS in a factory, it would still have to be disassembled for transportation, shipped, and then reassembled at the installation site.The objective of the field tests is to confirm that
04/07/2025
Consult
Tip
Consult
Tip
Intelligent switchgear opening and closing time operation acc to IEC 61850
For intelligent switchgear, the opening time is defined as the duration starting from the moment when the first message carrying the trip command (a GOOSE message in accordance with the IEC61850 series) is received through the interface, with the circuit - breaker initially in the closed position, and ending at the instant when the arcing contacts of all poles are separated.Regarding the closing time of intelligent switchgear, it refers to the time span from the reception of the first message co
03/18/2025
Consult
Tip
Consult
Tip
Loss evaluation in transformers based on IEC 60076
I. Definitions of Losses in IEC 6007IEC 60076-1 (General Requirements) and IEC 60076-7 (Loading Guidelines) specify two core types of losses:No-load Loss (P0)Definition: Losses measured when the primary winding is energized at rated voltage and the secondary winding is open-circuited (dominated by core losses).Test Conditions Measured at rated frequency and voltage (typically sinusoidal power frequency). Corrected to reference temperature (75°C for oil-immersed transformers, 115°
02/27/2025
Consult
Tip
Consult
Tip
SEKV-E: Parameter Extractor of Simplified EKV I-V Model for Low-Power Analog Circuits
This paper presents the open-source Python-based parameter extractor (SEKV-E) for the simplified EKV (sEKV) model, which enables the modern low-power circuit designs with the inversion coefficient design methodology. The tool extracts the essential sEKV parameters automatically from the given I - V curves using the direct extraction and the multi-stage optimization process. It also handles the overfitting issue because of non-linear least squares. Moreover, this work demonstrates t
03/06/2024
Consult
Tip
Consult
Tip