Live tank SF6 gas circuit breaker 145kV-362kV

  • Live tank SF6 gas circuit breaker 145kV-362kV

Key attributes

Brand ROCKWILL
Series RHB
Rated voltage 145 kV/252kV/362kV
Rated short-time withstand current up to 63 kA
Rated peak withstand current up to 158 kA
Rated frequency 50/60 Hz
Description

RHB Live Tank SF₆ Circuit Breaker uses self-blast arc extinguishing and three-phase porcelain post structure with CT spring mechanism and pointer density relay. Designed for outdoor 50Hz transmission network for load/fault current switching, available for single/three-pole switching and auto-reclosing, outstanding for low operating power and high reliability.

Core Advantages

  • Self-blast arc extinction design minimizes operating power;

  • Three-phase outdoor porcelain post insulation, strong environmental adaptability;

  • Pointer density relay continuously monitors SF₆ status to guarantee safe operation;

  • CT-type spring mechanism, stable action, low noise & easy installation.

Main technical parameters

Item Unit 145kV 252kV 363kV
Rated voltage kV 145 252 363
Rated frequency Hz 50/60

Rated current A up to 5000

Rated short-time withstand current, up to 3 s kA up to 63

Rated peak withstand current kA up to 158

1min power-frequency withstand voltage (earth) kV 275 460 460
1min power-frequency withstand voltage (across open contacts) kV 315 530 530
Rated lightning impulse withstand voltage, 1.2/50 μs (earth) kV 650 1050 1175
Rated lightning impulse withstand voltage, 1.2/50 μs (across open contacts) kV 750 1200 1380
Rated filling pressure (abs. at 20 ℃) circuit-breaker MPa 0.6

Minimum functional pressure (abs. at 20 ℃) circuit-breaker MPa 0.5

Ambient temperature range -30~+40

Type of installation Outdoor

Partial discharge pC <5

Annual SF₆ leakage rate <0.5%

Maintenance cycle Year 30

Working Principle

Upon trip signal, trip spring drives the integrated moving assembly (cylinder, moving arc contact & connecting rod) downward. Main contacts separate first, shifting circuit current onto closed arc contacts; arc generates once arc contacts part.

For short-circuit breaking, massive arc energy heats surrounding SF₆ gas and feeds high-temperature airflow into thermal expansion chamber to build high-pressure cold gas, closing the check valve. At current zero-crossing, high-pressure gas blasts across contact gap to quench arc efficiently. Meanwhile, compression chamber’s excess pressure opens bottom elastic pressure relief valve to release redundant gas pressure, drastically cutting required operating work of the spring mechanism and optimizing breaking performance.

 Live tank SF6 gas circuit breaker 145kV-330kV

 


Documentation Resource Library SF6 circuit breaker

Restricted
Outdoor live tank SF6 circuit breaker Outdoor live tank SF6 circuit breaker
Catalogue
English
PDF
Public.
RHB-145 Live tank SF6 gas circuit breaker FLYER RHB-145 Live tank SF6 gas circuit breaker FLYER
Brochure
English
Public.
RHB-252 Live tank SF6 gas circuit breaker FLYER RHB-252 Live tank SF6 gas circuit breaker FLYER
Brochure
English
Restricted
RHB Type Live tank SF6 gas circuit breaker 11kV…550kV RHB Type Live tank SF6 gas circuit breaker 11kV…550kV
Catalogue
English
PDF
Public.
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English
Public.
RHB-145 Live tank SF6 gas circuit breaker RHB-145 Live tank SF6 gas circuit breaker
Drawings
English
Public.
RHB-170(m) Live tank SF6 gas circuit breaker RHB-170(m) Live tank SF6 gas circuit breaker
Drawings
English
Public.
RHB-245 Live tank SF6 gas circuit breaker RHB-245 Live tank SF6 gas circuit breaker
Drawings
English

Frequently asked questions

In a live tank breaker, the arc chamber is mounted at the top or side of the column, exposed to ambient air. In a dead tank breaker, the arc chamber is placed inside the metal tank, fully sealed.

ABB’s high-voltage live-tank vacuum breakers are reliable but costly with long lead times. Hitachi Energy is mature yet lacks local high-voltage track records and smart features. Schneider Electric excels in 40.5kV distribution but is limited in voltage range and extreme performance. In contrast, Rockwill offers up to 363kV SF₆-free vacuum solutions with fast local service and spare parts delivery. Featuring robust mechanisms, full smart functions, and superior resistance to extreme cold, heavy salt fog, and short-circuit currents, our breakers ensure long maintenance-free service and lower LCC.

Q:Can Rockwill custom-engineer or modify Live tank Vacuum circuit breaker specifications to meet project-specific requirements?

A:
Rockwill provides comprehensive customized design and parameter modification for live tank vacuum circuit breakers to meet diverse project requirements. Backed by our professional R&D team, we flexibly adjust product structures, technical parameters and environmental adaptability, delivering exclusive tailored solutions in line with various on-site conditions and project standards.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register